18
DELTA R
TWILIGHT MODE
Up-Down
Up-Down
ENTER
TWILIGHT MODE MENU
This menu allow to set the unit in
Twilight mode.
Twilight mode let you turn ON and
OFF the unit at a specific clock time
(including day of the week) and/or
at a specific twilight level.
The Twilight mode make use of a
twilight sensor located on the front
panel near unit display.
To know the twilight ambient level
value measured from the sensor,
scroll the unit menu till MEASURE
Mode and select Twilight.
ENTER
The unit is switched on and off at
the desired twilight level or/and
at a specific clock time.
3)MOVING HEAD SETUP MENU
PAN MIN
PAN MAX
TILT MIN
TILT MAX
CALIBRATE PAN
CALIBRATE TILT
INVERT PAN
INVERT TILT
SWAP PAN & TILT
ENCODER
RESET PAN & TILT
SPEED PAN & TILT
Set TWILIGHT MODE
Mode : TWILIGHT
Actual : DMX
ENTER to CONFIRM
TWILIGHT Mode
ACTION CPR1
LEVEL ON 100 OFF 150:
TIME CONDIT INCLUSIVE
DAY Mon START 22:00
TIME ON 10:00
ACTION :
Let you select the desired
function in twilight mode.
You can choose between: DMX /
CPR1 / CPR2 / CPR1&2 / CRNB /
CUE 1-9 /
LEVEL ON and OFF :
Let you select the desired twilight
levels for:
Twilight mode ON and OFF.
TIME CONDITION:
Four different options are available:
1) INACTIVE
Clock time (START) and Time on period (TIME ON), are inactive.
In this condition the unit goes ON only if the twilight level is valid
2)COMBINED
Clock time (START), Time on period (TIME ON) and Twilight level are active.
In this condition, the unit goes ON only if all the parameters are valid.
3)INCLUSIVE
Clock time (START), Time on period (TIME ON) and Twilight level are active.
In this condition, the unit goes ON also if only one of the paramete is valid.
4)EXCLUSIVE
Clock time (START) and Time on period (TIME ON), are active, while Twilight level is inactive.
In this condition, the unit goes ON only if Clock time (START) is valid.
Up-Down
Menu
A001
MOVING HEAD SETUP
ENTER