DTS 03.TS046.46.A Скачать руководство пользователя страница 17

 

17 

 

 

MAIN MENU 

LEVEL 1 

LEVEL 2 

LEVEL 3 

FUNCTION 





To restore default settings 







LED temperature monitoring 





Micro controller temperature 
monitoring 





Output 1 of LED Driver board 
temperature monitoring 





Output 4 of LED Driver board 
temperature monitoring 





Shows the total unit life time and 
LED life time 







Software version 

 
 
 
13- MANUAL MODE 

 
Manual mode can be activated by pressing at the same time 

‘UP’ and ‘DOWN’ keys 

on unit display for 3 seconds (A001). 
In Manual mode it is possible to select the DIMMER level (range 0-255) as on DMX 
channel 2 and SHUTTER level (range 0-255) as on DMX channel 1. 
When Manual mode is active, unit switch OFF/ON cycle will maintain Manual Mode 
selection. 
In Manual mode the DMX signal is ignored. 

 
 
 
14- ERROR MESSAGES 
 
 

ERROR SHOWED ON DISPLAY 

APPEARS WHEN 



LED  thermal  sensor  damaged  (open  or  in 
short circuit).  
Unit immediately goes in black-out. 



LED temperature detected over 100°C. 
Unit immediately goes in black-out. 



Micro controller thermal sensor damaged 
(open or in short circuit).  
Unit immediately goes in black-out. 



Micro controller temperature detected over 
100°C. 
Unit immediately goes in black-out. 



Thermal sensor on output 1 of LED Driver 
board damaged (open or in short circuit).  
Unit immediately goes in black-out. 



Temperature detected over 100°C on 
output 1 of LED Driver board. 
Unit immediately goes in black-out. 



Thermal sensor on output 4 of LED Driver 
board damaged (open or in short circuit).  
Unit immediately goes in black-out. 



Temperature detected over 100°C on 
output 4 of LED Driver board. 
Unit immediately goes in black-out. 

 
 

Содержание 03.TS046.46.A

Страница 1: ...SCENA LED 200 USER S MANUAL rel 1 3 GB FR version PC version...

Страница 2: ...e products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ven...

Страница 3: ...9 6 2 Prevention of electric shock 9 6 3 Safety 9 6 4 Waste Electrical and Electronic Equipment directive 9 7 INSTALLATION 9 8 INPUT OUTPUT CONNECTIONS 10 9 DMX SIGNAL CONNECTION 11 9 1 DMX Addresses...

Страница 4: ...C ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE 2 GENERAL WARNING Read the instruction contained in this user manual carefully as they give important information regarding safety during installati...

Страница 5: ...Single high power White 3200K LED CRI 95 Also available with 4000K and 5600K LED LED lifespan 50 000 hours 70 lumen output Optical group 150 mm Fresnel lens 6 5 70 linear zoom Control DMX 512 RDM or M...

Страница 6: ...6 DIMENSIONS SCENA LED 200 FR...

Страница 7: ...ut Single high power White 3200K LED CRI 95 Also available with 4000K and 5600K LED LED lifespan 50 000 hours 70 lumen output Optical group 150 mm PC lens 6 4 64 linear zoom Control DMX 512 RDM or Man...

Страница 8: ...7 1 x XLR 5 pins male cable connector code 0508B148 1 x Filterframe black finishing already installed on the projector code 02M093278 46 1 x User s Manual Optional on request Barndoor black finishing...

Страница 9: ...l to the eyes and skin Do not stare at the operating light source The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified pe...

Страница 10: ...iling It is recommend the use of appropriate clamps to fix the unit to the mounting surface ATTENTION A safety cable code 0521A010 must be securely fixed to the unit s mounting bracket and to the supp...

Страница 11: ...11 8 INPUT OUTPUT CONNECTIONS...

Страница 12: ...of the second one In this way all the projectors are cascade connected If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX receptio...

Страница 13: ...r just add 4 Projector 3 A009 A projector 6 A021 9 2 Selecting the DMX address 1 Press the UP DOWN key until you reach the required DMX address The numbers on the display will start to flash but the n...

Страница 14: ...anufacturer Specific parameter as NO DMX ACTION DMX_PERSONALITY To set the DMX mode DMX_PERSONALITY_DESCRIPTION Description details of the DMX mode DEVICE_MODEL_DESCRIPTION Description details of the...

Страница 15: ...ware Upgrade Utility v 2 02 program At the end of the procedure the unit will reset For more information please refer to an authorised DTS service centre 12 DISPLAY FUNCTIONS The SCENA LED 200 display...

Страница 16: ...for linear light output Default Allows to select Linear current output Allows to adjust the PWM frequency value Hz in order to reduce flickering in the process of your camera recordings Default 610 H...

Страница 17: ...n Manual mode the DMX signal is ignored 14 ERROR MESSAGES ERROR SHOWED ON DISPLAY APPEARS WHEN LED thermal sensor damaged open or in short circuit Unit immediately goes in black out LED temperature de...

Страница 18: ...rom min to max 4 FUNCTIONS staying on desired option for 5 seconds 0 14 No function 15 24 SMOOTH OFF 25 26 SMOOTH 1 25 ms 27 28 SMOOTH 2 50 ms 29 30 SMOOTH 3 75 ms 31 32 SMOOTH 4 100 ms DEFAULT 33 34...

Страница 19: ...BOOST OFF 155 164 DISPLAY STAND BY OFF DEFAULT 165 174 DISPLAY STAND BY ON 175 176 NO DMX ACTION KEEP LAST DMX DEFAULT 177 178 NO DMX ACTION Black out 179 180 NO DMX ACTION LED ON 100 181 182 NO DMX A...

Страница 20: ...y system is certified to the ISO 9001 2015 standard D T S Illuminazione s r l Via Fagnano Selve 12 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts li...

Отзывы: