background image

SENSOR LAUNCH

After mounting the transmitter and magnet on the gate, it is necessary to calibrate the AZ-TX
transmitter and pair it with theAZ-FLEXRX receiving module in the FLEX receiver.

1.Calibration of theAZ-TX transmitter
- close the gate
- briefly press the transmitter button - the "ST" LED will flash
- open and close the gate once
- press the AZ-TX transmitter button again shortly - the "ST" LED will blink rapidly indicating the
success of the operation.

If the "ST" LED generates 2 pulses, the calibration procedure failed. The reason may be
too much distance between the AZ-MG magnet and the AZ-TX transmitter or too small
difference in the open and closed distance. Correct the assembly and repeat the
calibration procedure.

2. Pairing the transmitter with the FLEX receiver
- press the button on theAZ-FLEXRX module in the FLEX receiver - the diode will start to flash,
-open and close the gate - the diode will start to blink rapidly indicating the success of the operation.
Pairing can take place a few seconds after the opening of the gate.

3.Control of the sensor's operation.
When the gate is closed, the LED in the AZ-FLEXRX module in the FLEX receiver should be on. When
the gate is not closed, the LED should be off.

If the diode in the AZ-FLEXRX module blinks shortly every 5 seconds, it indicates a weak
battery in theAZ-TX transmitter paired with it.
If the diode in the AZ-TX transmitter generates 5 pulses, it may mean a low battery or
damage of the transmitter. Replace the battery. If the problem recurs despite the battery
replacement, please send the device for service.

PRESENTATIONOFTHEGATE STATE

Appropriate mounting of the AZYMUT sensor allows you to check the gate state on a mobile device
or computer.
The status of the gate is visible after adding a FLEX receiver, equipped with an WL card, to the
CloudFlex account (www.cloudflex.dtm.pl), and in the V-PILOT mobile application available for
Android and iOS devices.

There is a version of the Azymut sensor equipped with a Bluetooth module. The producer provides
the API for further implementation in order to connect to the device from the external application
level.

Содержание Azymut

Страница 1: ...WIRELESS GATE STATE SENSOR Installation and operating manual v 1 5 www dtm pl ...

Страница 2: ...ttes CD DVD players modern displays GSM phones and tablets laptops and computers remote control and access control transmitters monitors andTV sets medical devices for measuring and functional and life support functions e g pacemakers ventilators and other electronicdevices The magnet should not be close to any kind of measuring devices as it may disrupt the correct operationofthemeasuringdevicean...

Страница 3: ...LEXreceiverconnector dimensions 36x27x18mm frequency channel1 868 45MHz channel2 868 31MHz channel3 868 18MHz powersupply fromFLEXreceiverconnector antenna wire 868MHz AZ MGmagnet strongneodymiummagnetformountingonthegate dimensions 33x62x20mm AZ TX transmitter AZ MG magnet AZ FLEXRX receiving module plate holder programming button ST LED LED signaling radio communication battery holder arrows ind...

Страница 4: ...plateinthetransmitterhousing Fig 2 InstallationoftheAzymutsensorinvarioustypesofgates Garagedoor 1 Mount theAZ FLEXRXreceivingmodulein theFLEX receiver Fig 3 Settheinputin thesignaling modeintheFLEXreceivermenu Sr St on option seetheFLEXreceivermanual 2 MounttheAZ MGmagnetonthegateandtheAZ TXtransmitteronthewall orviceversa insuch awaythatthemagnetandthetransmitterareononelevelwhenthegateisclosed ...

Страница 5: ...achotherwhenthegateisclosed Fig 6 Slidinggate 1 Mount theAZ FLEXRXreceivingmodulein theFLEX receiver Fig 3 Settheinputin thesignaling modeintheFLEXreceivermenu Sr St on option seetheFLEXreceivermanual 2 MounttheAZ MGmagnetonthepost AZ TXtransmitteronthegate orviceversa insuchaway thatthemagnetandthetransmitterareoppositeeachotherwhenthegateisclosed Fig 7 Do not mount the transmitter in places expo...

Страница 6: ...ration Pairingcantakeplaceafewsecondsaftertheopeningofthegate 3 Controlofthesensor soperation When the gate is closed the LED in theAZ FLEXRX module in the FLEX receiver should be on When thegateisnotclosed theLEDshouldbeoff If the diode in theAZ FLEXRX module blinks shortly every 5 seconds it indicates a weak batteryintheAZ TXtransmitterpairedwithit If the diode in the AZ TX transmitter generates...

Страница 7: ...ressandholdthebuttonontheAZ TXtransmittertoconfirmthechannelselection Thediodewill blink signifyingthesuccessoftheoperation in the same way change the radio channel in theAZ FLEXRX receiver module installed in the FLEX receiver The channels set in the AZ FLEXRX module and in the AZ TX transmitter must be identical FORMATOFTHEAZ FLEXRXRECEIVINGMODULE To format the AZ FLEXRX module press and hold th...

Страница 8: ... warranty it is necessary to present a sales document Themanufacturerundertakestorepairthe device free of charge if there are defects due to the manufacturer s fault during the warranty period The defective device mustbedeliveredtotheplaceofpurchase including a copy of the proof of purchase and a brief unambiguous description of the damage The cost of disassembly and assemblyofthedeviceisbornebyth...

Отзывы: