21
4. Configuration
4.1. Range
The range setting is done with jumper J1 on the
transmitter and receiver.
The transmitter and receiver must be set to the same
range.
4.2. Operating mode
Mode setting is done with jumper J2 on the receiver.
SL (SLOW) -
allows you to reduce energy consumption from the
battery, the cost of extending the response time of the photocell to
obstacle appearance. Photocell in this mode does not comply with
safety standards PN-12445.
TR (TRIG)
- allows to reduce the consumption of battery power at a
time when supervised by a photocell automation system is at rest.
In this mode, the photocell
after power on (fig.5) or if
a change is detected at the
input T (Fig.5b) switches
the operating mode to
FAST and operates in
accordance with the
s a f e t y s t a n d a r d P N -
EN12445. After about 90s
photocell switches to
SLOW mode (slow down,
saving battery life). If the
input T is not connected or
is in a low state when
power on, the photocell
goes into a fast mode.
Fig.3.
Jumper J1
in transmitter and receiver.
J1
off
on
Range setting
maximum range 15m
maximum range 7m
J2 (receiver)
SL
TR
FA
FAST mode
SLOW mode
SLOW mode with FAST mode activation
Operation mode setting
Fig.5a.
Way to control the photocell with receiver power input.
PHOTOCELL RECEIVER POWER EX. FROM PHOTO-TEST OUTPUT OF GATE CONTROLLER
12...24V
0V
MODE
FAST
SLOW
90s
90s
<90s
<90s
>90s
>90s
>90s
Fig.5b.
Way to control the photocell with input T.
MODE
FAST
SLOW
90s
90s
SIGNAL TO PHOTOCELL RECEIVER INPUT T - ACTIVATION BEFORE EVERY GATE MOVE
12...24V
0V
> 90s
DTM System
spółka z ograniczoną odpowiedzialnością spółka komandytowa
ul. Brzeska 7, 85-145 Bydgoszcz
tel./fax. (52) 340-15-83, 340-15-84
www.dtm.pl, [email protected]
EN
Fig.4.
Jumper J2.
Содержание SLIMBAT II