background image

 

* Professional Sound System

                                                                                                              Conference Amplifier 

 

 

 

PAR

:  Parallel  operating  mode  indicator  (green).  When  the  amplifier  is  in  the  parallel  operation  mode,  this 

indicator light, then the input signal only applies to CH1. 

 

2.2 Rear panel description 

 

 

 

 

 

CH-1/CH-2 input socket 

The CH-1 / CH-2 input uses the standard XLR (female  base), the wiring method is: 1 foot: signal ground 2 

feet:  3 feet: signal -. Please refer to the instructions on the back panel of the machine. 

 

CH-1/CH-2 output socket 

The CH-1 / CH-2 output uses the standard XLR (male base), with the same XLR (female) connection can be 

used to output the same signal to another amplifier device. The wiring method is: 1 foot: signal ground 2 feet: 

 3 feet: signal -. Please refer to the instructions on the back panel of the machine. 

 

Limit 1/Limit 2 

 

CH-1/CH-2    35Hz High-pass filter 

Low-cut filter excises the band below 35Hz to protect the subwoofer from heavy vibration damage. 

 

Function mode switch 

Used to select stereo mode, bridge mode or parallel mode. 

 

CH-1/CH-2 Low frequency excitation 

Produced  by  the  bass  processor  to  control  the  amount  of  low  frequency  signal  from  0  to  infinity.  Adjust 

according to device parameters and personal preferences. 

Note:  The  bass  processor  should  be  used  with  care  to  avoid  possible  speaker  damage,  and  most  small 

economic speakers can not withstand the low frequency impact produced by the device. 

 

CH-1/CH-2 professional SPEAKON speaker socket 

When the device in stereo mode, you can use the SPEAKON socket to connect and the connection is: 1 +; 2 +. 

1-; 2- 

 

Amplifier output wiring column 

 

Recoverable fuse 

When the amplifier fails, the fuse will automatically disconnect. After stopping working and clearing the fault, 

press the fuse button to restore the connection to ensure normal work. 

 

Local power input socket 

 

Cooling fan window 

Do not block the cooling fan window under any circumstances. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

Содержание MX3000II

Страница 1: ...fier MX3000II MX3500II MX4000II User s manual Thank you for using our DSPPA public address system Please read this User Manual carefully to make better use of this equipment Guangzhou DSPPA Audio Co Ltd http www DSPPA com http www dsppatech com ...

Страница 2: ...ilar nature Connection Please disconnect other equipment from power source before they are connected to this product Please tune volume to its minimum level before the device is powered ON or OFF All terminals on the device marked with are live and dangerous and should be connected by trained personnel When abnormal conditions are realized Please disconnect the device from power source immediately...

Страница 3: ...Content I Features 1 II Appearance description 2 2 1 Front panel description 2 2 2 Rear panel description 3 Packing List 4 Performance Index 4 ...

Страница 4: ...impedance of 4Ω BTL work the minimum load impedance of 8Ω parallel work minimum load impedance of 2Ω With XLR signal input interface female base and XLR signal output interface male base flexible and convenient to use Amplifier output with a common wiring column and professional SPEAKON speaker socket only for stereo mode With short circuit protection DC protection power off and a variety of prote...

Страница 5: ...icator PRO CH 1 CH 2 protection indicator yellow There are three situations that the indicator lights up 1 3 to 5 seconds after the start and shutdown the power amplifier in the unstable work the amplifier away from the speaker 2 When the operating temperature of the power device exceeds 90 degrees 3 When the amplifier appears abnormal condition CLIP Peak indicator red There are two situations tha...

Страница 6: ...filter excises the band below 35Hz to protect the subwoofer from heavy vibration damage Function mode switch Used to select stereo mode bridge mode or parallel mode CH 1 CH 2 Low frequency excitation Produced by the bass processor to control the amount of low frequency signal from 0 to infinity Adjust according to device parameters and personal preferences Note The bass processor should be used wi...

Страница 7: ...W Rated output bridge 8Ω 1900W 2400W 3000W Input Interface 2 Speakon for Stereo Bridge Output Input Sensitivity 0 77V Input impedance 20kΩ balance 10kΩ unbalance SNR 98dB Damping coefficient 8Ω 1kHz 230 Frequency response 20Hz 20kHz 1dB Distortion 0 1 Channel crosstalk 62dB Conversion rate 15V uS Power Supply AC220 240V 50Hz Protection Soft start load short circuit voltage limit DC output power of...

Страница 8: ...ar nature Please do NOT remove the cover of the equipment otherwise you may get an electric shock Where necessary repair to the equipment should be conducted by qualified professionals All terminals on the device marked with are live and dangerous and should be connected by trained personnel This is connected to power source via the plug and any failure or danger occurs the user can disconnect the...

Отзывы: