                                                                                                                                                                                Conference Amplifier 

 

4. Instructions for use

 

4.1 Stereo mode of operation  

Stereo way is two-channel way. The work method on the rear panel of the machine (the switch in the figure below 

13 to the right to work for the stereo, dial to the left for the bridge to work) switch placed in the "2CH" bit is a 

two-channel mode. At this time the two channels are independent of their own, and the output phase with their 

own input signal in phase.The MX series has a minimum load impedance of 4 

Ω

  in two-channel mode.When the 

machine is working in stereo mode, the output power of each channel and matching with box is based on the 

power of single channel. But the total 

impedance of 2 channels is no less than 4 

Ω

 

 

 

 

 

 

 

 

 

4.2 Bridging operation 

Bridging operation can greatly improve the output power of the amplifier, in the choice of bridge work mode 

must be very clear about the power. 

Place the work mode selector switch on the rear panel of the machine in the "BTL" bit, which is the bridge 

operation. (B input is invalid). The amplifier output connection will be the two channels of the output of the "hot 

end"  (that  is  marked  with  "+"  level  symbol  of  the  terminal,  as  follows,  when  the  amplifier  is  connected  to  the 

output of the A channel input signal Shown) are connected to the two inputs of the speaker (output is useless). 

Note: do not ground any of the output terminals when bridging. 

The minimum load impedance at the time of bridging is 8 Ω.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MX1000II MX1500II MX2000II MX2500II
SERIES STEREO POWER AMPLIFIERS

SER.

NO.

DSPPA

F C

F B

F A

6AL

10AL

10AL

MX1000II

15AL

20AL

20AL

MX2500II

MX2000II

MX1500II

8AL

10AL

10AL

10AL

15AL

15AL

警告

请勿打开,以免触电

~220V/50Hz/15A

INPUT B

INPUT A

双通道立体声专业功放

-

BTL

+

OUT B

+

-

OUT A

-

+

BTL

2CH

F C

F A

F B

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION!

广州市迪士普音响科技有限公司

Guangzhou DSPPA Audio Co.,Ltd.

FUSE TYPE/

保险丝规格

1

2

3

4

5

6

7

8

9

MX1000II MX1500II MX2000II MX2500II
SERIES STEREO POWER AMPLIFIERS

SER.

NO.

DSPPA

F C

F B

F A

6AL

10AL

10AL

MX1000II

15AL

20AL

20AL

MX2500II

MX2000II

MX1500II

8AL

10AL

10AL

10AL

15AL

15AL

警告

请勿打开,以免触电

~220V/50Hz/15A

INPUT B

INPUT A

双通道立体声专业功放

-

BTL

+

OUT B

+

-

OUT A

-

+

BTL

2CH

F C

F A

F B

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION!

广州市迪士普音响科技有限公司

Guangzhou DSPPA Audio Co.,Ltd.

FUSE TYPE/

保险丝规格

 

 

Содержание MX1000II

Страница 1: ...1000II MX1500II MX2000II MX2500II User s manual Thank you for using our DSPPA public address system Please read this User Manual carefully to make better use of this equipment Guangzhou DSPPA Audio Co Ltd http www DSPPA com http www dsppatech com ...

Страница 2: ...onnection Please disconnect other equipment from power source before they are connected to this product Please tune volume to its minimum level before the device is powered ON or OFF All terminals on the device marked with are live and dangerous and should be connected by trained personnel When abnormal conditions are realized Please disconnect the device from power source immediately in case the ...

Страница 3: ... STEREO POWER AMPLIFIERS POWER POWER CLIP TEMP SIGNAL PROT 3 6 28 22 16 12 9 OdB 3 6 28 22 16 12 9 OdB CH A CH B 1 2 3 4 5 Cooling Fan The machine has cooling windows in left and right side respectively in order to guarantee the good ventilation do not block any of the ventilation when the machine is under operation Power Switch I for on O for off Channel A volume control knob Input attenuation Ma...

Страница 4: ...lass terminal connected to the speaker device level Channel A amplifier output class terminal connected to the speaker device level Channel A exchange fuse After the fuse is blown replace it with the same specifications fuse If the continuous fusing then the machine internal failure please remove the fault and then use the same specifications of the fuse to replace The machine AC220V power input c...

Страница 5: ...port and the black terminal is the signal ground When the bridge is running the speakers are bridged between two red bars between two hot ports and the ground is useless If the machine is alarmed after the power is applied and the machine alarm is activated the protection indicator is on it means that the output circuit may be short circuited The power supply should be cut off immediately and the ...

Страница 6: ... mode selector switch on the rear panel of the machine in the BTL bit which is the bridge operation B input is invalid The amplifier output connection will be the two channels of the output of the hot end that is marked with level symbol of the terminal as follows when the amplifier is connected to the output of the A channel input signal Shown are connected to the two inputs of the speaker output...

Страница 7: ... 400W Rated output channel 4Ω 250W 350W 450W 700W Rated output bridge 8Ω 500W 700W 900W 1400W Input Sensitivity 1 2dBV SNR 100dB Damping coefficient 8Ω 1kHz 200 1 Input common mode rejection 90dB Frequency response 20Hz 20kHz 0 5dB Harmonic distortion factor4Ω 1kHz 0 1 Channel impedance 4 16Ω Channel crosstalk 70dB Voltage gain 38dB Display power clip signal Power Supply AC220 240V 50Hz Protection...

Страница 8: ...ase do NOT remove the cover of the equipment otherwise you may get an electric shock Where necessary repair to the equipment should be conducted by qualified professionals All terminals on the device marked with are live and dangerous and should be connected by trained personnel This is connected to power source via the plug and any failure or danger occurs the user can disconnect the device from ...