background image

*

*

Four-Channel Matrix Power Amplifier

2

II. Description of Appearance

2.1 Description of Front Panel

MATRIX MIXER AMPLIFER  

MP912

VOLUME

CH1 CH2 CH3 CH4

DISTRIBUTOR

VOLUME

PROT

CH3

VOLUME

BASS TREBLE CH1 CH2

CH3 CH4

AUX 1

AUX LEVEL

MONITOR

CHIME

VOLUME

SIREN

MP3

VOLUME

VOLUME

CH4

VOLUME

CH1

VOLUME

CH2

VOLUME

BASS TREBLE

AUX 2

VOLUME

BASS TREBLE

AUX 3

VOLUME

BASS TREBLE

AUX 4

VOLUME

BASS TREBLE

AUX 5

VOLUME

CH1 CH2

CH3 CH4

TEL

MODE

CH3 CH4

CH2

CH1

MP3/BLUETOOTH

BASS TREBLE

PROT

PROT

PROT

10

8
6
4
2

CH2

POWER

CH1

CH3 CH4

CALL STATION

CH2

CH1

CH3 CH4

CH1 CH2

CH3 CH4

CH1 CH2

CH3 CH4

CH1 CH2

CH3 CH4

CH1 CH2

CH3 CH4

10

8
6
4
2

10

8
6
4
2

10

8
6
4
2

1

2 3

4 5 6

7 8 9 10

11

12

13

14

15 16 17 18 19 20

21 22 232425

26 27 28 29

1

Channel CH1 level indicator lamp

Indicate the input level of this channel, and for
channel CH2, CH3, CH4 and so on.

2

Channel CH1 power amplifier protection

indicator lamp

When using this channel, this indicator lamp is
alight, and for channel CH2, CH3, CH4 and so
on.

3

Channel CH1 volume adjustment knob

Turn it clockwise to increase the volume, and for

channel CH2, CH3, CH4 and so on.

4

Channel monitoring selection key

Press this key to select channel CH1, CH2, CH3
and CH4 in turn, and the corresponding indicator
lamp will be alight; in such case, adjust the
monitoring volume of this channel.

5

Channel monitoring volume adjustment knob

Press key 4 to select the channel, and then turn
this button to adjust the monitoring volume of
this channel.

6

Channel monitoring selection indicator lamp

When pressing key 4 to select the channel, the

corresponding channel indicator lamp will be alight.

7

Channel bell volume adjustment knob

Press the key 8 to turn on the bell; after pressing

the key 9 to select the channel, turn this knob to
adjust the bell volume of this channel.

8

Channel bell turn-on key

Press this key to turn on the bell.

9

Channel CH1 bell on-off key

Press this key, and the indicator lamp is alight,
indicating that this channel is selected at this
time, and then adjust the volume of the channel
bell. Press this key against to turn it off, and for
CH2, CH3, CH4 and so on.

10 Channel CH1 bell selection indicator lamp

Press the key 8 to turn on the bell; press the key
8 and the indicator lamp is alight, and then select
this channel, and for CH2, CH3, CH4 and so on.

11 Siren volume adjustment knob

Turn it clockwise to increase the volume.

12 Siren on-off key

Remove the white transparent shield and press
this key to give the alarm.

13 MP3 display screen

Display the playing.

14 MP3 control key

: Play/pause;

Содержание MP906

Страница 1: ...Public Address System Four Channel Matrix Power Amplifier MP906 MP912 ...

Страница 2: ...stem manufactured by DSPPA Company For the better application of this equipment please read the operation instruction carefully prior to use Guangzhou DSPPA Audio Co Ltd http www DSPPA com http www dsppatech com This page is left blank for keeping note by user ...

Страница 3: ...cautions for use instruction to connection of system and instruction to operation of product and so on The user shall read this operation instruction carefully prior to connection installation and use and shall operate in accordance with the instructions herein The attention must be paid to the instructions with such identification on the back panel of the machine Please use or operation the machi...

Страница 4: ...t Please do not put any weight on this equipment Do not operate switch and button or connect the external audio source equipment with overexertion Prevent the entry of any foreign matter e g paper and metal through the clearance or opening of the equipment into it in such case please disconnect the power supply immediately Do not try to remove any component in the equipment or transform it in any ...

Страница 5: ...UCT 1 1 1 DESCRIPTION OF EQUIPMENT 1 1 2 PERFORMANCE CHARACTERISTICS 1 II DESCRIPTION OF APPEARANCE 2 2 1 DESCRIPTION OF FRONT PANEL 2 2 2 DESCRIPTION OF REAR PANEL 2 III INSTRUCTION TO CONNECTION 2 PACKING LIST 4 PERFORMANCE SPECIFICATION 5 ...

Страница 6: ...quipments and 1 channel of telephone signal input Adjustable volume the remote paging microphone is connected to this equipment with the crystal plug and this equipment is connected to the telephone line with the telephone socket i e this equipment is an slave machine connected to this telephone set Fire alarm signal Adjustable volume and bell sound source Adjustable volume With built in MP3 modul...

Страница 7: ...ct channel CH1 CH2 CH3 and CH4 in turn and the corresponding indicator lamp will be alight in such case adjust the monitoring volume of this channel 5 Channel monitoring volume adjustment knob Press key 4 to select the channel and then turn this button to adjust the monitoring volume of this channel 6 Channel monitoring selection indicator lamp When pressing key 4 to select the channel the corresp...

Страница 8: ...er and for AUX2 AUX3 and so on 22 Auxiliary output AUX1 volume adjustment knob Press key 25 to select the channel so as to adjust the volume of such channel 23 Auxiliary output AUX1 treble adjustment knob TREBLE Adjust this knob with screwdriver and for AUX2 AUX3 AUX4 AUX5 and so on 24 Auxiliary output AUX1 channel CH4 indicator lamp Press the key 25 to select the channel and this indicator lamp i...

Страница 9: ...our channels of lines 4 Telephone signal input module ADDRESS VOLUME IN TEL 1 2 3 4 ON a b c a Address dial up b Telephone line socket c Volume adjustment knob 5 Matrix 4 channel output interface Four channels of power output each of which has independent 4 16Ω terminal 70V terminal and 100V terminal Connect the loudspeaker 6 RS232 interface It is used to expand the computer to control this equipm...

Страница 10: ...RITY RS232 TEL 100V 70V 4 16 CH1 ZONE OUTPUTS COM 100V 70V 4 16 CH2 COM 100V 70V 4 16 CH3 COM 100V 70V 4 16 CH4 COM 8 MONITOR 1 3 2 4 RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION MP906 F4AL250V F6AL250V MP912 DSPPA F A 16V 22V 4 16 FUSE TYPE Nur Sicherung 250V Use Only With A 250V Fuse Employer Unlquement Avec Fusible De 250V 1 2 3 4 ON MIC CD player Pure driver amplier Monitoring CM12 Telecommunica...

Страница 11: ...any fault in the equipment the non professional person shall not disassemble the housing for repair without the approval in order to prevent accident or aggravate the damage to the equipment Do not put any corrosive chemicals nearby or on the equipment 2 Precautions for after sales service In case of the installation and operation according to this instruction the company will provide the free war...

Страница 12: ...Warranty card 1 copy 3 Certificate 1 copy 4 Operation instruction 1 copy 5 10A GB power line 1 piece 6 1500MM double modulator audio line 1 piece 7 6 35R lotus plug 2 pieces 8 4P lockable green plug 2ERJKM 5 08 4P 4 pieces 9 2P green plug 2ERJK3 81 2P 2 pieces 10 H21 612 remote controller 1 piece ...

Страница 13: ...ion If the power switch of the equipment is off the machine is not disconnected to the grid for the purpose of safety please pull the power line plug out of the socket if this equipment is not in service This equipment shall not suffer from water dripping or spraying Do not place the vase full of water onto the equipment Do not open the cover plate of the machine without authorization to prevent e...

Отзывы: