background image

5

Figure 2-2

(1) Zone function description

All zone detection:

press this button to detect all 20 zones.

Single zone detection

: press this button and choose a zone to detect. Note: no other operation could be

done at the same time.

Single zone calibration:

press this button and choose a zone to calibrate (only zones that are

successfully connected and load rate is not 100% could be calibrated individually). Note: no other

operation could be done at the same time.

All zone on

: press this button to turn on all zones.

Fault Ack:

this button will turn red and give alarm when there is light load or overload in some zones.

Press it to stop giving alarm.

Status display

: click “

” to enter the interface as Figure 2-4.

System settings:

click “

” to enter the interface as Figure 3-1.

(2) Zone status description

: normal load, zone off

: normal load, zone on

: load open circuit, zone off

: load open circuit, zone on

: light load, zone off

Содержание MAG2126

Страница 1: ...OWER MAG2126 20 Zones Speaker Selector Line Detector User s Manual Welcome to use DSPPA public address system For the better use of this product please read this instruction carefully prior to use Gua...

Страница 2: ...ly cold or hot Please do NOT place any heavy article on this equipment Please operate switches buttons or external audio source carefully Please prevent foreign matters such as paper metal etc enterin...

Страница 3: ...ppearance 1 2 1 Description of front panel 1 2 2 Description of rear panel 2 3 Connection Diagram 3 3 1 System connection 3 4 Operation Instruction 3 4 1 Start up 3 4 2 Introduction to Main Interface...

Страница 4: ...each zone even a zone that is turned off Support real time detection of load status of closed zone With load short circuit protection function automatic return to normal status after troubleshooting...

Страница 5: ...M 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT O...

Страница 6: ...OM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT OUTPUT COM 100V COM 100V INPUT...

Страница 7: ...detection and single zone detection for used zone is within 20 the error of real time detection for unused zone is within 10 Therefore if the detection data changes when performing scheduled detection...

Страница 8: ...ad rate is not 100 could be calibrated individually Note no other operation could be done at the same time All zone on press this button to turn on all zones Fault Ack this button will turn red and gi...

Страница 9: ...1 5K 0 25W resistors into the unused output as shown in Figure 2 3 this interface with resistor is not allowed to connect the amplifier output so that all the zones will be displayed normally Figure...

Страница 10: ...7 Figure 2 5 4 3 System Settings Figure 3 1...

Страница 11: ...or overload and press ENTER when the settings are complete to save the settings Note threshold set for all zones will override threshold for each zone 3 Backlight time click five options 1 minute 10...

Страница 12: ...y disconnected from power source when it is switched OFF For sake of safety please disconnect the device from the socket if it is not in use Please do NOT place the device where it is extremely cold o...

Страница 13: ...device as supporting documents The following conditions are beyond the scope of warranty 1 Product damage due to improper installation use or handling 2 Product damage due to abnormal conditions such...

Страница 14: ...able 1 Specification Note The performance specifications are subject to changes without further notification Item Parameter Channel withstand capacity 100V Input Max power 500W 70V Input Max power 350...

Страница 15: ...remove the cover of the equipment otherwise you may get an electric shock Where necessary repair to the equipment should be conducted by qualified professionals All terminals on the device marked with...

Отзывы: