User Manual
AUBION X.8
13/29
6.1.14 Advanced settings
A dialog for advanced settings for the
X.8
can be found in the
File/Device Settings...
menu item
below the
Connection
tab.
When you see the green
button labeled
Stable Audio
Connection
, the data connection
is working free of errors. If the
message
Audio Drop-Outs
Detected
appears in red, please
increase the
I/O Buffer
until the
connection is stable. There are
other events in the network
connection that can lead to
errors in the data transport.
If an error of this type occurs, then
Audio Drop-Outs Detected
appears in red. This message can
be reset using the
Reset
button. If the error occurs several times, then the
I/O Buffer
should
also be increased here.
In normal cases, the
AUBION X.8 Setup / Connection
is not open. An error text appears below
the
Device:
box in the main window. If this message occurs during a measurement, the
measurement must be repeated.
If a connection error occurs repeatedly, you can find out the specific error parameters using
Show Statistics.
Hide Statistics
closes the window again. So that you do not have to write down
all values of the connection parameters, you can create a log file using
Logging activated
. The
log file “
dev_log_AubionX8_...log
“ is written under Windows
7 in the
C:\ProgramData\AUBION\X.8\
file (path of the standard installation under Windows 7).
The best thing is to send all files in this folder to Support if you are requested to do so.
Please deactivate
Logging activated
during normal operation to avoid performance losses.
Please notice: Some ASIO-applications do not automatically detect latency changes. Before
changing the device´s
I/O Buffer
please close any open measurement or streaming software
that is making use of
the
X.8
(e.g. SysTune). Perform the change and then reopen the
software. This assures the program will identify the buffer change.