![DSC PowerSeries SCW9045-433 v1.0 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/dsc/powerseries-scw9045-433-v1-0/powerseries-scw9045-433-v1-0_installation-and-wiring-manual_2534745053.webp)
Appendix A: Reporting Code Formats
49
Appendix A: Reporting Code Formats
The following tables contain Contact ID and Automatic SIA format reporting codes.
See Programming Sections [320]-[348] for Reporting Codes
Contact ID
The first digit (in parentheses) will automatically be sent by the control. The second two digits are programmed to indicate specific information about the
signal. For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would receive the following:
*BURG - ENTRY/EXIT - 1 where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hard Coded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard - October 1997. This
format will send the Account Code along with its data transmission. The transmission will look similar to the following at the receiver:
N Ri1
BA 01
N
= New
Event
Ri1
=
Partition /Area Identifier
BA
= Burglary
Alarm
01
= Zone
1
NOTE: A system event will use the Area Identifier Ri00.
Section #
Reporting Code
Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto
Rep Codes**
[320]-[323]
Zone Alarms
Zone goes into alarm
A/R
See the following tables on next
page for details
[324]-[327]
Zone Restorals
Alarm condition has been restored
A/R
[328]
Duress Alarm
Duress code entered at keypad
A/R
(1) 21
HA-00
[328]
Opening After Alarm
System disarmed with alarm in memory
A/R
(4) 58
OR-UU
[328]
Recent Closing
Alarm occurs within two minutes of system arming
A/R
(4) 59
CR-00
[328]
Cross Zone (Police Code)
Alarm
Two zones on the same partition go into alarm during any given
armed-to-armed period (incl. 24Hr zones)
A/R
(1) 39
BM-00/BV-00
[328]
Burglary Not Verified
This event is transmitted when a second cross zone alarm does
not occur within the Cross Zone timer
A/R
(3) 78
BG-00
[328]
Alarm Cancelled
Sent when the system is disarmed after an alarm, but before the
expiry of the Alarm Cancel timer
A/R
(4) A6
BC-00
[329]
[F] Key Alarm/Rest.
Keypad fire alarm (alarm and restoral rep. codes sent together)
A/R
(1) 1A
FA-00/FH-00
[329]
[A] Key Alarm/Rest.
Keypad auxiliary alarm (alarm and restoral rep. codes sent
together)
A/R
(1) AA
MA-00/MH-00
[329]
[P] Key Alarm/Rest.
Keypad panic alarm (alarm and restoral rep. codes sent together) A/R
(1) 2A
PA-00/PH-00
[330]-[337]
Zone Tamper/Restoral
Zone is tampered / tamper condition restored
T/R
(3) 83
TA-ZZ/TR-ZZ
[338]
General System Tamper/
Rest.
Case/cover has a tamper alarm. Case/cover tamper restored
T/R
(1) 45
ES-00/EJ-00
[338]
Keypad Lockout
Maximum number of incorrect access codes has been entered at
a keypad
T/R
(4) 61
JA-00
[339-341]
Closings
System armed (user 01-16, 40 indicated)
O/C
(4) A1
CL-UU
[341]
Bypass Zones
Sent when zone is bypassed
O/C
(5) 7A
UB-ZZ
[341]
Partial Closing
One or more zones bypassed when system armed
O/C
(4) 56
CG-00
[341]
Special Closing
Closing (arming) using one of the following methods: quick arm,
keyswitch, function key, maintenance code, DLS software, wire-
less key
O/C
(4) AA
CL-00
[341]
Exit Fault
Sent when an Exit Error occurs and the Entry Delay expires
before the system is disarmed
O/C
(3) 74
EE-00
[342-344]
Openings
System disarmed (user 01-16, 40 indicated)
O/C
(4) A1
OP-UU
[344]
Special Opening
Opening (disarming) using one of the following methods: key-
switch, maintenance code, DLS software, wireless key
O/C
(4) AA
OP-00
[345]-[346]
Battery Trouble/Rest.
SCW System battery is low/battery restored
MA/R
(3) A2
YT-00/YR-00
[345]-[346]
AC Line Trouble/Rest.
AC power to control panel is disconnected or interrupted/AC
power restored (Both codes follow AC Failure Comm. Delay.)
MA/R
(3) A1
AT-00/AR-00
[345]-[346]
Fire Trouble/Rest.
Trouble occurs/Restoral on a fire zone
MA/R
(3) 73
FT-00/FH-00
[345]-[346]
Auxiliary Power Trouble/
Rest.
Aux voltage supply trouble/restoral
MA/R
(3) 12
YP-00/YQ-00
[346]
TLM Restoral
Telephone line restored
MA/R
(3) 51
LR-01
[345]-[346]
Gen. System Trouble/Rest.
“Service Required” trouble occurs (view troubles using [*][2])/trou-
ble restored
MA/R
(3) AA
YX-00/YZ-00
[347]
Phone# 1 or 2 FTC Restoral Control panel has restored communications to central station on
Phone# 1 or 2 (after FTC)
MA/R
(3) 54
YK-00
[347]
DLS Lead In
Downloading session start
MA/R
(4) 11
RB-00
[347]
DLS Lead Out
Downloading session complete
MA/R
(4) 12
RS-00
[347]
Zone Fault/Rest.
One or more zones have faults/restored
MA/R
(3) 80
UT-ZZ/UJ-ZZ