Section 8: Programming Descriptions
39
Section [381] Second Communicator Options
Section [382] Third Communicator Options
Section [401] First Downloading Options
Option
Description
[1]
ON:
Opening After Alarm Keypad Ringback Enabled.
When the Opening After Alarm reporting code is successfully transmitted
to a programmed telephone number, the keypad will sound a series of 8 beeps to confirm to the end user that the Opening After Alarm
Code was sent and received. This Ringback will occur for each Opening After Alarm code successfully reported.
OFF:
Opening After Alarm Keypad Ringback Disabled.
[2]
Future Use
[3]
ON:
SIA Uses Programmed Reporting Codes.
The system uses programmed reporting codes when transmitting using the SIA format.
OFF:
SIA Uses Automatic Reporting Codes.
The system automatically generates all reporting codes transmitted.
[4]
ON:
Closing Confirmation Enabled.
The system beeps the keypad 8 times after transmitting a
Closing
reporting event.
OFF:
Closing Confirmation Disabled.
The keypad does not beep.
[5]-[6]
Future Use
[7]
ON: Contact ID Uses Programmed Reporting Codes.
The system uses
Contact ID format
programmed reporting codes when
transmitting reporting codes.
OFF:
Contact ID Uses Automatic Reporting Codes.
The system automatically generates all reporting codes transmitted.
[8]
Future Use
Option
Description
[1]
ON:
Partial Closing Identifier is ‘5’.
The system will use the digit
[5]
as the first digit of the Partial Closing reporting code when
transmitting Contact ID reporting codes.
OFF:
Partial Closing Identifier is ‘4’.
The system will use the digit
[4]
as the first digit of the Partial Closing reporting code when
transmitting Contact ID reporting codes.
[2]
ON:
Alarm Communications Enabled During Walk Test.
The system will transmit all alarms during Walk Test.
OFF:
Alarm Communications Disabled During Walk Test.
The system will not report alarm events during Walk Test.
[3]
ON:
Communications Cancelled Message Enabled.
The keypad will display the message ‘
Communications Cancelled
’ upon
successful transmission of the Communication Cancelled reporting event.
OFF:
Communications Cancelled Message Disabled.
The keypad will not display these messages.
(ON for SIA CP-01).
[4]
ON:
Call Waiting Cancel Enabled.
The system dials the Call Waiting Cancel string on the first attempt to dial the central station.
OFF: Call Waiting Cancel Disabled.
The system does not dial the Call Waiting Cancel string.
[5]
Future Use
[6]
ON: AC Failure Transmission Delay in Hours.
The AC Failure Transmission Delay timer will be in hours.
OFF: AC Failure Transmission Delay in Minutes.
The AC Failure Transmission Delay timer will be in minutes.
[7]
ON:
Residential Dialing Attempts are 1.
Number of Dialing Attempts is one when using Residential Dial communication format.
OFF:
Residential Dialing Attempts are 5.
Number of Dialing Attempts is five when using Residential Dial communication format.
[8]
Future Use
Option
Description
[1]
ON: Answering Machine Double Call Enabled.
The system answers incoming calls for downloading (either Programmed Number
of Rings or Double Call).
OFF:
Answering Machine Double Call Disabled.
The system does not answer incoming calls for double
call attempts, but will still answer on Programmed Number of Rings.
These settings do not affect the 6 hour DLS downloading window on power up.
[2]
ON:
User Can Enable DLS Window.
The user can enable downloading for the DLS downloading window (double call only) using
the
[ ][6]
command.
OFF:
User Can NOT Enable DLS Window.
The user can not enable the DLS downloading window using the
[ ][6]
command.
[3]
ON: Call Back Enabled.
The system will hang up after a successful DLS connection and call the computer back using the DLS
Phone Number (Section
[402]
).
OFF:
Call Back Disabled.
The system stays connected to the computer.
[4]
ON:
User Initiated Call-up Enabled.
The user can initiate a downloading session using the
[ ][6]
command.
OFF:
User Initiated
Call-up Disabled.
The user cannot initiate a downloading session.