2. Complete all output wiring.
3. Connect the external tamper switch, if used.
Consult the above wiring diagrams for further information.

3.4

Applying Power

After all wiring is completed, apply power to the control panel.
Connect the battery leads to the battery, then connect the AC
transformer. Then, connect power to thePC6204: the battery
leads followed by the AC transformer. For more information
on control panel power specifications, see the control panel
System Manual.

NOTE

: Do not connect the power until all wiring is complete.

4. Enrolling the Module

NOTE: 

By default, before you can enroll modules, or change

any system programming, a user must tell the system to
“Allow System Service”.  The system will then allow access to
Installer’s Programming for 60 minutes. Any user with a
Master code can tell the system to allow service at a system
keypad. The default Master code is [1234].
See the Maintenance Manual for more information. See the
Programming Manual – “Download Section” for more
information on the “User Allows Serv” toggle option.

Once all wiring is complete, the module must be enrolled on
the system. To enroll the module, perform the following:

1. Pressing [*] [8] [Installer’s Code].

PC6204 Outputs

4204 Options   0 - 06 -

 

2 - 01

16

Module Number: PC6204 # 

I______I______I

Area

Date

Pulse

Alarm Seismic

No. Output*  1   2   3   4   5   6   7   8   9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26  2 7  28 29 30 31 32

Zone

Schedule Timer

Group Group

1

I_____I_____I

I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I_____I____I____I____I____I____I

I_____I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

2

I_____I_____I

I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I_____I____I____I____I____I____I

I_____I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

3

I_____I_____I

I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I_____I____I____I____I____I____I

I_____I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

4

I_____I_____I

I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I____I_____I____I____I____I____I____I

I_____I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

I_____I_____I

* List of Output Options:

[00] Fire and Burg

[11] Courtesy Pulse

[22] Exit Follow

[33] Battery Test

[44] Inv Date Sched

[01] Inv Fire / Burg

[12] Chime Follower

[23] Entry Follow

[34] Auxiliary Alrm

[45] Inv Hold Up

[02] Burg Only

[13] TLM Only

[24] Date Schedule

[35] Medical alarm

[46] Inv Set

[03] Inv Burg Only

[14] Failure to Comm

[25] Hold Up

[36] Seismic Pulse

[47] Inv Tbl Group

[04] Fire Only

[15] Combus Power

[26] Set

[37] Alarm Group

[48] Inv Tamper

[05] Inv Fire Only

[16] Ready Status

[27] Trouble Group

[38] Inv Area Status

[49] Inv Cond. Al.

[06] Utility Output

[17] Zone Alarm

[28] Tamper

[39] Inv Latch Strobe

[50] Inv Police Code

[07] Sensor Reset

[18] Zone Follow

[29] Condition. Al.

[40] Inv Trouble O/P

[51] Inv Aux Alm

[08] Area Status

[19] Duress Output

[30] Police code

[41] Inv Zn Alarm

[52] Inv Medical Alm

[09] Latched Strobe

[20] Buzzer Follow

[31] Momentary O/P

[42] Inv Zn Follow

[53] Inv Seismic O/P

[10] Trouble Output

[21] Remote Operation

[32] Maintained O/P

[43] Inv Duress O/P

[54] Inv Alarm Group
[55] APS Controlled

2. Scroll to “Module Hardware” and press the [*] key.
3. Scroll to “Enroll Module” and press the [*] key.
4. Scroll through the different modules until “PC6204” is

displayed. Press the [*] key.

5. The message “Create Tamper on Desired Unit” will be

displayed. To create the required tamper, secure the tamper
zone on the module and then open it. The transition from
secure to violated enrolls the module. After this is done, the
keypad will display the module number and will confirm
enrollment (e.g. “PC6204 Mod 01 Enrolled”).

For more information regarding module enrollment, see the
control panel System Manual.

5. Programming the Module

To access PC6010 programming, have a user allow system
service, then enter [*][8] followed by the Installer’s code. Each
relay output must be programmed. The programming
worksheet located below indicates which sections must be
programmed. For more information regarding how to
program, see the control panel System Manual.

NOTE: 

The output options listed below are for PC6010 v2.0.

For programming other software versions, see the
corresponding programming manual.

NOTE:

If you will be using Relay 1 for Combus Power, make

sure that you program the output for option [15] Combus
Power, and that you set jumper J1 to “Combus Relay”.