PC6204HC High Current
Relay Output Module

 Installation Instructions

Please refer to the System Installation Manual for information on limitations regarding product

use and function and information on the limitations as to liability of the manufacturer.

1. Introduction

The PC6204 is an output module with four programmable
relay outputs. Relay 1 can be used to repower the Combus.

NOTE:

 Do not use any power supply other than the PC6204

to repower the Combus. If a power supply other than the
PC6204 is used, the Combus repower function will not
operate as intended. See the control panel System Manual
for details regarding this feature.

2. Specifications

2.2A Power Supply

Current Draw: 30 mA (from Combus)

Minimum 80VA 16-18V transformer required

Minimum 7Ah battery required up to 36Ah max.

Connects to control panel via 4-wire Combus

Four programmable relay contacts rated 2A, 30V

DC

AUX current: 1.2A with low charging current

800mA with high charging current

Tamper contact input

Selectable battery charging current (800mA or 1.2A)

Up to16 modules per system

Compatible Cabinets

PC4003C

PC4006C

3. Installing the PC6204

3.1

Unpacking

The PC6204 package should include the following parts:

One PC6204 circuit board

One ground wire assembly

Five plastic stand-offs

One 5A replacement fuse

3.2

Mounting

The PC6204 should be located inside a compatible cabinet,
mounted in a dry, secure location. Preferably, it should be
placed at a convenient distance from the connected devices.

Perform the following steps to mount the unit:

1. Press the five plastic stand-offs through the mounting holes

at back of the cabinet.

2. Secure the cabinet to the wall in the desired location. Use

appropriate wall anchors when securing the cabinet to
drywall, plaster, concrete, brick or other surfaces.

3. Press the circuit board into the plastic stand-offs to secure

the module to the cabinet.

Once the unit is mounted, wiring may be completed.

3.3

Installation and Wiring

Before beginning to wire the unit, ensure that all power (AC
transformer and battery) is disconnected from the control
panel.

Perform the following steps to complete wiring:

1. Connect the four Combus wires to the PC6204. Connect

the red, black, yellow and green Combus wires to the RED,
BLK, YEL and GRN terminals, respectively.
If Relay 1 is being used for Combus Power, connect the
Combus wires according to the following diagram. Note
that for this option, Jumper J1 must also be set for
“Combus Relay.”

CONTROL

PANEL

NOTES:

1. The connection to the mains supply must be made as
per the local authorities’ rules and regulations. In the UK,
as per BS6701.

2. If during the installation a knockout is removed, it is
the installer’s responsibility to ensure that the same degree
of protection for the cabinet is provided by the use of
bushings, fittings, etc.

3. The cabinet must be secured to the building structure
before operation.

4. The equipment is intended to be installed by SERVICE
PERSONNEL ONLY or equivalent (e.g.: persons having
appropriate technical training and experience necessary to
be aware of hazards to which they are exposed in
performing that task.

5. Internal wiring shall be routed in a manner that
prevents:

- excessive strain on wire and on terminal connections;
- loosening of terminal connections;
- damage of conductor insulation.

6. The external power supply shall meet the applicable
requirements of the Low Voltage Directive.