[2] Interior Zone  

is normally used with interior motion detectors

and has the standard Exit Delay time. The zone also has
the standard Entry Delay time provided that a delay zone
has been tripped first. If the premises are entered without
coming through a “delay” entrance, and a type [2] zone
is tripped, an immediate alarm will be generated.

[3] Interior Home-away Zone  

operates the same as the type

[2] zone with the following exception. If the system is
armed and the delay zone is NOT tripped during the Exit
Delay time, the type [3] zone will be bypassed. Instead of
the interior portion of an interior Home-away zone, a
Home-away zone can have a delay equal to the standard
Entry and Exit Delay when Section [32], light 3 is ON. This
will affect all Home-away zones when they are not
bypassed by [

][1][

][9] arming, or by arming and not

leaving the premises. If Home-away zones are
automatically bypassed or [

][9] arming bypassed and

the user then enters [

][1], the Home-aways will then

have a delay.

[4] 24 Hour Bell  

is active at all times and will create an alarm

if the panel is armed or disarmed. This zone will always
activate the bell/siren output.

[5] 24 Hour Bell/Buzzer  

operates as the type [4] except the

bell/siren output is activated only when the panel is armed
and only the keypad buzzer is activated while the panel
is disarmed.

[6] 24 Hour Buzzer  

operates as the type [4] except only the

buzzer will be activated in the armed or disarmed mode.

[7] Auxiliary Delay Zone  

operates the same as the type [0]

zone except the Entry/Exit Delays can be independently
set in Section [18]. This zone type is useful when a zone
with an Entry and/or Exit Delay is required that is different
from the standard times as established for type [0] zones
in Section [17]. If Section [32], light 5 is ON it will enable
the system to be armed even if the auxiliary delay zone is
open (“Ready” light ON). Also, the system can be armed
with the auxiliary delay zone closed and then it can be
opened before the Auxiliary Exit Delay has expired. In
both cases the auxiliary delay zone will not become active
until both the Auxiliary Exit Delay has expired and the
zone is closed.

[8] Fire Zone  

Although a common fire signal is reported, any

number of the 6 zones may be programmed as a fire zone.
A fire zone is a supervised (N.O. alarm initiating contacts),
end-of-line resistor circuit designed to accept latching 4-
wire smoke detectors.  See the fire circuit installation drawing.

On alarm, fire zone shorted, the bell / siren will pulse to
indicate that a fire zone has been activated.  Transmission
by the digital communicator is delayed 30 seconds.  If
the alarm is acknowledged before the 30 second delay
has expired, pressing the [#] key will silence the alarm
and abort the transmission.  If the alarm is NOT
acknowledged within the 30 second period, transmission
will proceed and cannot be aborted.  If the alarm has
been silenced and all smoke detectors are not restored
to normal, the alarm will re-sound after 90 seconds; 30
seconds after that, the communicator will transmit.  If the
alarm re-sounds, it may again be silenced by pressing
the [#] key and the communicator transmission will be
aborted if the alarm is silence within the 30 second
transmission delay period.

To restore the smoke detectors to normal, clear all
products of combustion from the detectors and perform a

reset by pressing the [

] then [7] keys.  See Section [24]

for programming the PGM terminal for smoke detector
reset.  Pressing [

][7] will remove power from the smoke

detectors for 5 seconds; if the detectors are clear of
smoke, they will return to normal.  If the detectors still have
smoke in them, the alarm will re-sound and the sequence
described above will repeat.

For an open on any zone programmed for fire, the
“Trouble” light will come ON and the keypad sounder will
beep every 10 seconds.  The keypad trouble buzzer will
sound and the “Trouble” light will come ON regardless of
whether the panel is armed or disarmed.  The
communicator will transmit the trouble condition if
programmed in Section [09].  The audible trouble indication
may be silenced by pressing the [#] key.  The “Trouble”
light will only go OFF when all the fire zone troubles are
cleared.  To determine the type of trouble, press [

][2].

Section [11], Digit #2 Summary:

[0] = Standard Delay Zone
[1] = Instant Zone
[2] = Interior Zone
[3] = Interior Home/Away Zone
[4] = 24 hour Bell Zone
[5] = 24 hour Bell/Buzzer Zone
[6] = 24 hour Buzzer Zone
[7] = Auxiliary Delay Zone
[8] = Fire Zone

[12]

1st System Option Code

The 1st System Option Code is set using the zone lights as
shown in the table below.  Once Section [12] is entered, the
6 zone lights will indicate the status of each option.  Press a
number key corresponding to the zone light number to turn the
option ON and OFF.  Pressing [0] will turn all the zone lights
OFF and the options will be set as shown against “Light Off”.

ZONE

LIGHT

[1]

ON =

Communicator disabled

• OFF =

Communicator Enabled

[2]

ON =

Transmission per 24 hour period

• OFF =

Transmission per armed period

[3]

• ON =

Alarm display while armed

OFF =

No alarm display while armed

[4]

• ON =

DTMF dialling

*

OFF =

Pulse dialling

[5]

ON =

N.C. zones (except fire zones)

• OFF =

End-of-line resistor zones

[6]

• ON =

Keypad [P]anic audible

OFF =

Keypad [P]anic silent

Factory default settings

*

DTMF dialling will default to pulse dialling after 2
unsuccessful DTMF dialling attempts.

Содержание PC-LINK9

Страница 1: ...INSTALLATION MANUAL PC15OO ...

Страница 2: ... exploitation et de sécurité des réseaux de télécommunications Le Ministère n assure toutefois pas que le matétiel fonctionnera à la satisfaction de l utilisateur Avant d installer ce matériel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale detélécommunication Lematérieldoitégalementêtreinstallé en suivant une méthod acceptée de raccordement D...

Страница 3: ...ditions 2 6 Alarm Memory 3 6 Downloading Callup Command 4 6 User Programming Command 5 Master Code 6 EEPROM Reset 7 User Function Commands 6 Master Code 7 Setting the Clock 6 Master Code 1 7 Set Auto Arm Time 6 Master Code 2 7 Quick Arm ON OFF 6 Master Code 4 7 Auto Arm ON OFF 6 Master Code 5 7 Door Chime ON OFF 6 Master Code 6 7 Bell Test 6 Master Code 8 8 Installer s Test ON OFF 6 Master Code 0 ...

Страница 4: ...n Variables 14 16 Zone Bypass Mask 14 17 System Times 14 18 Auxiliary Delay Zone Entry Exit Times 15 19 System Clock Times 15 20 New Installer s Code 15 21 New Master Code 15 22 2nd Master Code 15 23 Communication Formats 15 24 Programmable Output Options PGM Terminal 16 25 Communicator Call Direction 16 26 Downloading Telephone Number 17 27 Downloading Access Code 17 28 Panel Identification Code ...

Страница 5: ...it Operation Download Upload capability Programmable auto downloading Swinger shutdown Transmission delay Six access codes Master Code All zones programmable as fire zones Programmable test transmission Zone bypass from the keypad Six zones Bell Siren zone Programmable output Three dedicated keys Fire Auxiliary Panic Backlit aesthetically pleasing keypad SPECIFICATIONS PC1500 Control Panel Six ful...

Страница 6: ...egative output which can be controlled by various programming options See Programming Guide Section 24 Devices controlled by the PGM output must be connected between the PGM terminal which is and the AUX terminal Keypad Wiring Up to three keypads may be connected in parallel Do not connect multiple keypads on the same keypad wire run For Standby Loading purposes use a current draw of 35 mA per key...

Страница 7: ...ctor s fail a fire zone trouble will be initiated Burglary Zone Wiring Burglary zone definition eg Delay Instant 24 Hr etc is Zone Wiring Chart Figures based on maximum loop resistance of 100 ohms Wire Gauge Max Run Length to AWG End of Lineresistor 24 1900 579m 22 3000 914m 20 4900 1493m 19 6200 1889m 18 7800 2377m programmed via the keypad See the Programming Guide Section 11 AC Power Wiring Com...

Страница 8: ...Smoke Detector mounting Dead Air Space The FIG 4 Smoke Detector mounting Dead Air Space The FIG 4 Smoke Detector mounting Dead Air Space The smoke from a fire generally rises to the ceiling spreads smoke from a fire generally rises to the ceiling spreads smoke from a fire generally rises to the ceiling spreads smoke from a fire generally rises to the ceiling spreads smoke from a fire generally ris...

Страница 9: ...will be ON if a zone is bypassed and if Show Bypassed Status While Armed is programmed in Section 31 zone light 4 ON See Installer s programming Section 8 command for instructions on changing the Exit Delay time Auto bypass Home away Arming If a correct access code is entered and you do not exit the premises the system will at the end of the Exit Delay time arm with interior zones automatically by...

Страница 10: ...sing the key to exit from the trouble view mode 5 Fire Alarm Circuit Trouble An open circuit on the zone programmed as a Fire Zone will initiate a trouble See Zone Definitions Section 11 for Fire Zone assignment 6 Loss of Time on System Clock When the PC1500 is powered up or reset the internal time of day clock needs to be reset to the correct time The trouble is cleared after entering the trouble...

Страница 11: ...H MM 3 Reserved for future use 4 Quick Arm Enable Disable 5 Auto Arm Enable Disable 6 Door Chime Enable Disable 8 Bell Test Function 9 Reserved for future use 0 Installer s Test turn off after use This function will turn off automatically on arming Items 4 5 6 and 0 turn ON and OFF various features When the item key is pressed and the feature is being turned ON the keypad sounder will beep 3 times...

Страница 12: ...ed light will continue to flash to remind the user that the Entry Delay is not applied to the Delay Zones Also the Bypass light will be shut OFF to indicate that the Home Away zones are no longer bypassed Note that the 1 command will not remove bypasses from zones that have been manually bypassed Quick Exit 0 when Armed Entering 0 when the system is armed will allow the user to exit the premises t...

Страница 13: ...r the new digit from the keypad If you wish to keep that digit unchanged you can enterthesamenumberorskipthedigitbypressingthe F key Once the first digit has been entered or skipped the 4 zone lightswilldisplaythevalueoftheseconddigit Aftereachdigit isenteredorskipped thezonelightsshowthevalueofthenext digit in the binary format When the required data for the section being programmed is completely...

Страница 14: ...r base 16 format HEX numbering uses the digits 0 through 9 and the letters A through F The letters A through F are represented by the number keys 1through6 ToenterdatainHEXformat firstpressthe key The Ready light will flash Enter the HEX value then press the key again to return to the normal entry mode The Ready light will stop flashing To enter HEX numbers A Enter 1 B Enter 2 C Enter 3 D Enter 4 ...

Страница 15: ...ing code Section 05 and 06 each have 6 reporting codes Sections 07 08 and 10 each have 7 reporting codes while Section 09 has 8 reporting codes Once a section is entered the system expects a series of 2 digit numbers to be entered The keypad beeps twice and the Armed light flashes after each 2 digit entry After the last 2 digit number is entered programming of the current section is complete The k...

Страница 16: ...on of the F A and P keys will only take place if the appropriate sections in 09 are programmed with a reporting code 10 Maintenance Alarms and Restorals These reporting codes are used by the communicator to transmit the following list of alarms and restorals See Section 05 as a guide to programming Low Battery Alarm AC Failure Alarm Fuse Failure Alarm Low Battery Rrestore AC Failure Restore Fuse F...

Страница 17: ...he digital communicator is delayed 30 seconds If the alarm is acknowledged before the 30 second delay has expired pressing the key will silence the alarm and abort the transmission If the alarm is NOT acknowledged within the 30 second period transmission will proceed and cannot be aborted If the alarm has been silenced and all smoke detectors are not restored to normal the alarm will re sound afte...

Страница 18: ...digit number defines the number of attempts alarm and restoral pairs per zone that the communicator will make before it shuts down for that zone swinger shutdown The number of attempts is for the period as defined in the 1st System Option Code Section zone light 2 The number of attempts may be programmed from 00 to 99 where 00 means the communicator will never shut down The fire zone cannot be shu...

Страница 19: ...ring the code complete entry of the 4 digits then enter the section number again to enter the correct code Do not press or while entering the code 23 Communication Formats This section sets the type of format which will be sent to each of the two telephone numbers programmed in Section 01 and 03 For each telephone number enter one digit from the list below See the HEX data programming section for ...

Страница 20: ...e keypad buzzer is ON for 24 Hour Buzzer Zone Door Chime Entry Delay and Auto Arm Alert 07 System Status Armed Disarmed ThePGMoutputswitchestoandremainsatgroundaslong as the panel is armed The output goes high open while the panel is disarmed 08 Strobe Output Latched Alarm Output The PGM switches to ground on an alarm and remains low until the panel is disarmed It can be used to indicate that an a...

Страница 21: ...FF Restore as follower when zone restores Factory default 32 5th System Option Code Use the same programming method as in Section 12 ZONE LIGHT 1 ON Loss of AC will not cause an AC trouble OFF Loss of AC will cause AC trouble 2 ON No bell during Auto Arm burst every 10 seconds is silenced OFF 1 burst of bell siren every 10 seconds during Auto Arm pre alert 3 ON Home Away zones will have an entry d...

Страница 22: ...umber of invlaid codes are entered Program a time from 00 to 99 minutes 90 Installer s Lockout Enable This feature is enabled by entering 90 while in the installer s programming mode A factory default hardware or software will not reset the installer s code or the download access code once this feature is enabled A panel that has this feature enabled will give a distinct audible indication upon po...

Страница 23: ..._________________________________ ZONES Zone Type Protected Area 1 _____________________________ __________________________________________________________________ 2 _____________________________ __________________________________________________________________ 3 _____________________________ __________________________________________________________________ 4 _____________________________ ______...

Страница 24: ...in the account code For a 3 digit code enter 0 for the 4th digit 03 2nd Phone Number Page 11 04 2nd Account Code Page 11 05 Zone Alarm Reporting Codes Page 11 For single digit reporting codes enter 0 as the second digit Enter 1 HEX A to transmit a 0 zero 10 pulses Zone 1 Alarm Zone 2 Alarm Zone 3 Alarm Zone 4 Alarm Zone 5 Alarm Zone 6 Alarm 06 Zone Restoral Reporting Codes Page 11 For single digit...

Страница 25: ...g if an alarm occurred during the previous armed period Access Code 1 Access Code 2 Access Code 3 Access Code 4 Access Code 5 Access Code 6 After Alarm Code 09 Priority Alarms and Restorals Page 12 Actuation of the F A or P keys will immediately transmit both an alarm and restoral code There is no delay on the restoral code transmission Fire Zone Trouble Keypad P anic Alarm Keypad F ire Alarm Keyp...

Страница 26: ... 0 2 Zone 4 0 2 Zone 5 0 8 Zone 6 First Digit Second Digit 0 Slow Audible 0 Standard Delay 1 Slow Silent 1 Instant 2 Fast Audible 2 Interior 3 Fast Silent 3 Interior Home away 4 24 Hour Bell 5 24 Hour Bell Buzzer 6 24 Hour Buzzer 7 Aux Delay Uses Aux Entry Exit Delays 8 Fire Any one zone may be set as a FIRE zone 12 1st System Option Code Page 13 Default Zone Light ON Zone Light OFF OFF Zone Light...

Страница 27: ...ight ON Zone Light OFF OFF Zone Light 1 User code required for bypass Code not required OFF Zone Light 2 4 Enabled 4 Disabled OFF Zone Light 3 Periodic downloading Periodic test transmit OFF Zone Light 4 4 access code required 4 no code required ON Zone Light 5 P anic audible buzzer P anic silent OFF Zone Light 6 Partial closing identified Not identified 15 Communication Variables Page 14 Default ...

Страница 28: ... minutes 0 5 0 Slow zone response time 10 ms 0 3 0 Test transmission cycle or auto download cycle time days Valid entries are 001 to 255 do not enter 000 18 Auxiliary Delay Zone Entry Exit Times Page 15 Default 0 4 5 Entry Time seconds 1 2 0 Exit Time seconds Valid entries are 001 to 255 19 System Clock Times Page 15 Default 9 9 9 9 Automatic Arming time of day 9 9 9 9 Test transmission or auto do...

Страница 29: ...N DCI VERTEX 20 BPS 2300 Hz handshake 3 1 4 1 and 4 2 non extended formats 2 SILENT KNIGHT FAST 20 BPS 1400 Hz handshake 3 1 4 1 and 4 2 non extended formats 3 RADIONICS 2300 1400 Hz handshake 3 1 4 2 non extended formats 4 RADIONICS 2300 1400 Hz handshake 3 1 4 2 non extended with parity format 5 DO NOT USE 6 DO NOT USE 7 DO NOT USE 8 SILENT KNIGHT ADEMCO SLOW 10 BPS 1400 Hz handshake 3 1 extende...

Страница 30: ...etely Do not press to exit until all entries are completed Default 1 Zone Alarms and Restorals 1 Access Code Openings and Closings 1 Priority Alarms and Restorals 1 Maintenance Alarms and Restorals 0 No transmissions for this group 1 Call 1st number and backup to 2nd number 2 Call 2nd phone number only 3 Always call both phone numbers Section 13 Light 1 OFF and 2nd phone number must be programmed ...

Страница 31: ... AC 60 Hz OFF Zone Light 6 Restore on bell time out Restore as follower If zone light 4 is ON bypass status will always be shown If zone light 4 is OFF bypass status is shown only when the panel is disarmed 32 5th System Option Code Page 17 Default Zone Light ON Zone Light OFF OFF Zone Light 1 AC excluded from trouble AC included OFF Zone Light 2 No bell during auto arm Bell during auto arm ON Zon...

Страница 32: ...lay OFF Zone Light 6 F Key disabled F Key enabled 35 LINKS1000 Test Reporting Code Page 18 Default F F Program this section only if the LINKS1000 Cellular Alarm Transmitter is being used with the PC1500 36 Keypad Lockout Control Page 18 Default 0 0 Number of Invalid Codes before lockout 0 0 Lockout Duration minutes Enter 2 2 digit numbers in the range of 00 to 99 Program the Number of Invalid Code...

Страница 33: ...or detailed instructions on keypad wiring AC AUX BELL PGM KEYPAD Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 R 1 T 1 RNG TIP YEL GRN WHT Battery capacity for emergency standby is at least 4 hours if the total load BELL AUX output is 800mA or less Recommended battery is Yuasa MNP4 12 Do not connect transformer to a receptacle controlled by a switch Suggested Transformer Basler Electric BE116240CAA 0002 For fire ...

Страница 34: ...s and shall be in lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd This warrantycontainstheentirewarranty DigitalSecurityControls Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or ...

Страница 35: ... 1994 Digital Security Controls Ltd 1645 Flint Rd Downsview Ontario Canada M3J 2J6 Tel 416 665 8460 Fax 416 665 7498 ...

Страница 36: ... Entry Delay The Keypad sounder will sound a quick pulsing tone during the last 10 seconds of the Entry Delay to warn that the Entry Delay is about to expire Zone Light 5 Bell Squawk During Entry Delay The bell siren will squawk during the Entry Delay If Zone Light 4 is on the bell siren squawk will quicken during the last 10 seconds of the Entry Delay LINKS1000 Support The following items have be...

Отзывы: