DSC Maxsys PC4164 Скачать руководство пользователя страница 8

6

Section 2: Getting Started

This section describes how to set up and enroll the PC4164 module. 

2.1 Unpack the PC4164

Check that the following parts are in your PC4164 package:

• PC4164 PCB

• PC4164 plastic cabinet

• 2 antennas

2.2 Install the Antennas

Attach both antennas to the terminals marked ANT1 and ANT2, (not GND1 
and GND2). Install the antennas ONLY as shown in the following diagrams: 

DO NOT install the antennas this way:

2.3 Find a Mounting Location for the PC4164

NOTE: 

Do not permanently mount the PC4164 now. Mount the PC4164 

receiver after you have done placement tests with all the wireless 
devices (see sections 4.1 and 4.2).

Find a place that is:

• Dry

• Central to the proposed placement of all wireless devices

• As high as possible

• Far from sources of interference, including: electrical noise such as com-

puters, televisions and electric motors in appliances and heating and air 
conditioning units; large metal objects like heating ducts and plumbing 
which may shield the antenna. 

Make sure that electrical wires will not run over the antenna(s) of the mod-
ule when it is mounted.

When mounting the PC4164 in a basement, place the module as high and as 
close to the underside of the first floor as possible. The range of the module 
will be smaller if the unit is mounted below ground level.

Содержание Maxsys PC4164

Страница 1: ...llation Manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read ...

Страница 2: ...arm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits If necessary the user should consult the dealer or an experienced radio television technician for additional sugges tions The user may find the following booklet prepared by the FCC helpful How to Ident...

Страница 3: ...Enroll and Program Wireless Keys WLS909 10 3 4 Enroll and Program Handheld Keypads WLS910 12 4 Testing Mounting Devices 14 4 1 Test the Placement of WLS904 WLS905 WLS906 WLS907 WLS912 WLS914 and WLS915 Devices 14 4 2 Test WLS908 WLS909 and WLS910 Reception 15 4 3 Mount the PC4164 and Wireless Devices 16 4 4 Battery Test For WLS908 Panic Pendants 16 5 Deleting Replacing Devices 17 5 1 Replacing Dev...

Страница 4: ...em may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the resi dence or building Ever...

Страница 5: ... 1 system you can only enroll one PC4164 v2 1 module Support for the following wireless devices mini universal transmitter WLS915 glassbreak detector WLS912 dual PIR motion detector WLS914 1 1 Before You Begin This manual describes how to install program and maintain the PC4164 on a PC4010 4020 Security System You should have completed the following steps in your PC4010 4020 installation before yo...

Страница 6: ...s and wireless keys see Sections 7 and 8 For help with troubleshooting see Section 9 Record the zone or slot and serial numbers of all wireless devices and other programming in the Programming Worksheets section at the end of the man ual PC4010 4020 Programming All programming sections in this manual are referred to by reference num ber A detailed description of PC4010 PC4020 programming is in the...

Страница 7: ...e used 1 4 Wireless Devices NOTE Please refer to the Installation Instruction sheets of the following devices for more information The PC4164 v2 1 can receive signals from the following devices This unit is listed as a single or multiple station smoke detector accessory WLS904 Motion Detector WLS905 Universal Transmitter WLS906 Smoke Detector WLS907 Universal Transmitter WLS908 Panic Pendant WLS90...

Страница 8: ...r you have done placement tests with all the wireless devices see sections 4 1 and 4 2 Find a place that is Dry Central to the proposed placement of all wireless devices As high as possible Far from sources of interference including electrical noise such as com puters televisions and electric motors in appliances and heating and air conditioning units large metal objects like heating ducts and plu...

Страница 9: ...cting the PC4164 The PC4164 is connected to the control panel via the Combus CAUTION Remove all power from the panel while connecting modules to the Combus Wire the PC4164 to the Combus of the PC4010 PC4020 according to dia gram 1 Diagram 1 ...

Страница 10: ...cription of how to enroll keypads and modules is in your PC4010 PC4020 Installation Manual Follow these steps to enroll your PC4164 module 1 At a PC4010 4020 system LCD keypad enter 8 Installer s code to go to the Installer s Programming section 2 Enter Ref 0200 to go to the Enroll Module section 3 Scroll to PC41XX Zn Ex press The LCD keypad will display Create Tamper on Desired Unit 4 Tamper the ...

Страница 11: ...es test each one in its intended mounting location to make sure that it can communicate properly with the PC4164 Test the device 2 3 times See Section 4 1 for more information 1 At a system LCD keypad enter 8 Installer s code 2 Enter Ref 001300 to go to the Enroll Device programming section This section will only be available if you have enrolled the PC4164 with the panel see Enroll the PC4164 on ...

Страница 12: ...the PC4164 on page 8 The LCD keypad will dis play Enroll Device Serial 3 Look at the back of the wireless key If it has a 6 digit serial number enter it now If it only has a 5 digit number enter a 0 and then the 5 digit number 4 The display will show Enroll Device WKEY XX where XX the Wkey slot to which the WLS909 is assigned 01 to 16 5 Record the serial number and assigned slot number in the prog...

Страница 13: ...function you want to select or scroll to the function you want to assign to that button and press The follow ing functions may be programmed 00 Null Key 07 Arm Interior 01 Stay Arm 08 15 7 Command Outputs 1 8 02 Away Arm 16 Fire Alarm 03 No Entry Arm 17 Auxiliary Alarm 04 Chime On Off 18 Panic Alarm 05 System Test 19 Disarm Off 06 Quick Exit NOTE If programmed these options do not require access c...

Страница 14: ...ck of the handheld keypad If it has a 6 digit serial num ber enter it now If it only has a 5 digit number enter a 0 and then the 5 digit number 4 The display will show Select 01 Partition 1 Scroll to the partition the keypad will be enrolled on Press to select the partition for the key pad NOTE Handheld keypads will not work when the partition they are assigned to are being accessed for zone bypas...

Страница 15: ...u want to program 1 4 Press 4 Enter the 2 digit number of the function you want to select or scroll to the function you want to assign to that button and press The follow ing functions may be programmed 00 Null Key 05 System Test 01 Stay Arm 06 Quick Exit 02 Away Arm 07 Arm Interior 03 No Entry Arm 08 15 7 Command Outputs 1 8 04 Chime On Off NOTE If a programmed function requires access code entry...

Страница 16: ...these devices 1 Temporarily place the device in its intended mounting location 2 At a system LCD keypad enter 8 Installer s code 3 Enter Ref 001303 to go to the Device Test section 4 Enter 00 to have test results sounded on the keypad buzzers only Enter 01 to have test results sounded by the system bells as well as the key pad buzzers 5 Use the keys to scroll to the device and press to select it T...

Страница 17: ...64 and the devices are in good or fair locations 9 To exit installer programming press 4 2 Test WLS908 WLS909 and WLS910 Reception The panic pendant WLS908 wireless key WLS909 and handheld keypad WLS910 cannot be tested using the module placement test described above To ensure that the PC4164 is receiving transmissions from these devices conduct the following tests WLS908 Press the Test button at ...

Страница 18: ... See the Installation sheet for each device for mounting instruc tions 4 4 Battery Test For WLS908 Panic Pendants Panic Pendants cannot be tested using the module placement test or the walk test You must assign panic pendant zones to one or more partitions before you can test the Panic Pendants Follow these steps to test Panic Pen dants 1 Begin testing when your PC4010 4020 system is in the ready ...

Страница 19: ...0 1 At a system LCD keypad enter 8 Installer s code 2 Enter Ref 001302 to go to the Replace Device section The LCD key pad will display Serial and either Zone XXX Wkey XX or HHK XX 3 Use the keys to scroll to the device to be deleted then press The LCD keypad will display With Device Serial 4 Enter the serial number of the new device The LCD keypad will display Device Replaced Serial Zone XXX NOTE...

Страница 20: ...amming will not be affected When you re enroll the wireless devices remember to change the zone and partition program ming if necessary 1 At a LCD keypad enter 8 Installer s code 2 Enter Ref 001308 or scroll to Default Wireless and press 3 The LCD will display Confirm Default Press To confirm the default procedure press To cancel the default procedure press any other key 5 4 Deleting PC4164 Module...

Страница 21: ...ion that the PC4164 receives from the miss ing zone will restore communication with that zone and restore the Zone Supervisory Fault The Device Fail timer will also be reset WLS908 Panic Pendant The panic pendant does not transmit a supervisory signal This is so that the user will be able to take it away from the premise You must disable wireless supervision for each zone a panic pendant is assign...

Страница 22: ...e will be transmitted The low battery alarm and restore codes will only be reported once per armed period The Low Battery Restore transmission is not delayed The default transmission delay is 7 days To change the transmission delay 1 At a LCD keypad enter 8 Installer s code 2 Enter Ref 00040211 to go to the 4164 Low Bat Dly section 3 Enter the new transmission delay from 000 to 255 days 4 To exit ...

Страница 23: ...ls the user that the PC4164 is not receiving wireless device transmissions The panel will transmit the General System Trouble reporting code The default setting for this option is OFF To enable warning of this trouble condition 1 At a LCD keypad enter 8 Installer s code 2 Enter Ref 000200 to go to the System Toggles section 3 Scroll to RF Jam Detect 4 Press to toggle the option ON or OFF 5 To exit...

Страница 24: ...ry testing the device in the same room as the receiver Confirm that the PC4164 is properly connected to the Combus see section 2 for PC4164 set up and wiring instructions Check that you are testing the zone correctly see sections 4 1 on page 14 and 4 2 on page 15 for testing instructions Check that the batteries are working and installed correctly Look for large metal objects that may be preventin...

Страница 25: ...l_____l l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l_____l_____l_____l l_____l_____l_____l l_____l_____l_____l_____...

Страница 26: ..._______l l_____l_____l l__________l l_____l_____l l__________l l_____l_____l l__________l 03 l_____l_____l l__________l l_____l_____l l__________l l_____l_____l l__________l l_____l_____l l__________l 04 l_____l_____l l__________l l_____l_____l l__________l l_____l_____l l__________l l_____l_____l l__________l 05 l_____l_____l l__________l l_____l_____l l__________l l_____l_____l l__________l l___...

Страница 27: ...Test 19 Cancel Key 06 Quick Exit 20 Zone Control Handheld Keypad Serial Number Partition No Button 1 Button 2 Button 3 Button 4 01 l_____l_____l_____l_____l_____l_____l l__________l l_____l_____l l_____l_____l l_____l_____l l_____l_____l 02 l_____l_____l_____l_____l_____l_____l l__________l l_____l_____l l_____l_____l l_____l_____l l_____l_____l 03 l_____l_____l_____l_____l_____l_____l l__________...

Страница 28: ...___l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l l_____l_____l_____l l__________l...

Страница 29: ...room utility room and hallways not pro tected by the required detectors NOTE The Smoke Detector is designed to use Eveready Energizer E91 Alkaline Batteries Do not use other brands of batteries with the Smoke Detector Using brands other than the Eveready Energizer will void UL approval and may affect the system s operation Figure 1 A smoke detector should be located between the sleeping area and t...

Страница 30: ...tion detector test 14 Mounting devices 16 PC4164 16 N Number reference 4 serial 9 slot 10 zone 9 P Panic pendant supervision 19 Partition programming for buttons 11 for handheld keypads 12 Placement of smoke detectors 27 test 14 Problems 22 Programming how to 4 R Reference numbers 4 Removing devices 18 Replace devices 17 RF jamming detection 21 S Serial numbers 9 erasing 18 Slot number handheld ke...

Страница 31: ...f attempts will be limited to a replacement of the product as the exclusive remedy for breach of warranty Under no circumstances shall Digi tal Security Controls Ltd be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any other legal theory Such damages include but are not limited to loss of profits loss of t...

Страница 32: ... 1999 Digital Security Controls Ltd Toronto Canada www dscgrp com Printed in Canada 29004884 R001 ...