background image

The HS2LCDWF wireless keypad is compatible

with the HS2016/32/64 and HS2128 PowerSeries

Neo wireless panels.

Specifications

Unpacking

The HS2LCDWF keypad package is available in

five distinct configurations, described below

.

The keypad contains patented technology for the

Proximity (Prox) Tag

.

Mounting

Mount the keypad where it is accessible from desig-

nated points of entry and exit. Once a dry and secure

location has been selected, perform the following

steps to mount the keypad.

Wall Mounting Plate

1. Locate the screw holes (4) at each corner of the

mounting plate.

2. Use the four screws provided to affix the mount-

ing plate to the wall; ensure the mounting tabs

are facing you (see diagram below). If the keypad

is to be mounted on drywall, use plastic anchors

(not supplied). 

3.Align the four mounting slots in the HS2LCDWF

housing with the four mounting tabs protruding

from the mounting plate. 

4. Slide the keypad into place.

5. Firmly but carefully snap the keypad down onto

the mounting plate. 

Desk Stand -

HS2LC-

DWFDMK

 

1. Insert the four rub-

ber feet (found in

the hardware pack)

into the indentations

provided in the bot-

tom of the desk

stand.

2. Place the desk stand on a secure, uncluttered sur-

face.

3.Align the four mounting slots in the HS2LCDWF

housing with the four mounting tabs protruding

from the desk stand. 

4. Slide the keypad into place. Firmly but carefully

snap the keypad down onto the desk stand.

5. To fasten the keypad securely onto the desk

stand, locate the hole in the centre of the bottom

of the desk stand. Using the screws provided,

screw the keypad to the desk stand.

Apply Battery Power

1. Slide the keypad up and out from the mounting

plate/desk stand (removing the screws first if

required). The bay for the four AA batteries is

open and visible at the back of the keypad.

2. Insert the batteries as directed on the back of the

keypad. Ensure the correct polarity is observed.

3. Replace the keypad on the mounting plate/desk

stand.

Installation Instructions

• Temperature range: -10°C to +55°C (14°F to 131°F)

UL/ULC: 0°C to +49°C (32°F to 120°F)

• Humidity (MAX): 93%R.H. non-condensing
• Plastic enclosure protection degree: IP30, IK04
• Power adaptor output voltage: 9.0V

DC

 @ 1.25A. Mod-

els - US/Latin America: 

xx

; Canada: 

xx;

 EU: 

xx

; UK: 

xx

; AUS./NZ: 

xx;

 China: xx limited power supply, 

acceptable to the authority having jurisdiction

• Battery: 4 AA, 1.5 V, Energizer alkaline consumer-

grade

• Low Battery Indication: 4.3 V
• HS2LCDWF current draw: 

50

mA 

• Wall-mount tamper
• 5 programmable function keys
• Ready (Green LED), Armed (Red LED), Trouble/RF 

Jam (Red/Yellow LED), AC (Green LED)

• Frequency: 433.92MHz (

xx only/xx only)

• Frequency: 868.35MHz (

xx only)

• Frequency: 915MHz 

(xx only)

• Up to 128 wireless zones

NOTE: DSC recommends that the keypad be powered by

the AC adaptor and the batteries for EN installations.

When the power adaptor is used, batteries provide mini-

mum 24h back-up.

HS2LCDWF - wall mount HS2LCDWFP - prox tag

• 1 HS2LCDWF keypad • 1 HS2LCDWF keypad
• 1 HS2LCDWF wall 

bracket

• 1 HS2LCDWF wall 

bracket

• 1 Installation Manual

• 1 Installation Manual

• 1 inner door sticker

• 1 inner door sticker

• 4 AA batteries

• 4 AA batteries

• 1 hardware pack

• 1 hardware pack
• 1 prox tag

HS2LCDWFPV - prox 

tag w/ verbal 

annunciation

HS2LCDWFPV - prox 

tag w/ verbal annuncia-

tion and transformer 

• 1 HS2LCDWFBRK wall 

bracket

• 1 HS2LCDWFBRK wall 

bracket

• 1 Installation Manual

• 1 Installation Manual

• 1 inner door sticker

• 1 inner door sticker

• 1 power adaptor

• 1 power adaptor

• 4 AA batteries

• 4 AA batteries

• 2 hardware packs

• 2 hardware packs

• 1 prox tag

• 1 prox tag
• 1 transformer

HS2LCDWFPV - prox tag w/ verbal 

annunciation, transformer and deskstand

• 1 HS2LCDWFBRK wall 

bracket

• 1 transformer

• 1 Installation Manual

•1 HS2LCDWFDMK desk 

stand

• 1 inner door sticker
• 1 power adaptor
• 4 AA batteries
• 2 hardware packs
• 1 prox tag

Screw hole

Screw hole

Screw hole

Screw hole

Mounting tab

Mounting tab

Mounting tab

Mounting tab

Содержание HS2LCDWF v1.0

Страница 1: ...ual with which this equipment is intended to be used Operating Instructions shall be made available to the user NOTE This Installation Sheet applies to the following models HS2LCDWF HS2LCDWFP and HS2LCDWFPV NOTE Do not dispose of the waste battery as unsorted municipal waste Consult your local rules and or laws regarding recycling of this battery it will help protect the environ ment HS2LCDWF v1 0...

Страница 2: ... directed on the back of the keypad Ensure the correct polarity is observed 3 Replace the keypad on the mounting plate desk stand Installation Instructions Temperature range 10 C to 55 C 14 F to 131 F UL ULC 0 C to 49 C 32 F to 120 F Humidity MAX 93 R H non condensing Plastic enclosure protection degree IP30 IK04 Power adaptor output voltage 9 0VDC 1 25A Mod els US Latin America xx Canada xx EU xx...

Страница 3: ...is wired to the alarm panel and power has been applied power up a wireless keypad 2 Press any button on the keypad to enroll it on the HSM2HOST The HSM2HOST is then automatically enrolled on the alarm panel Enrolling Keypad 1 Enter 8 Installer Code and then section 804 000 2 When prompted either activate the device to enroll immediately or enter a device serial num ber Do the latter to pre enroll ...

Страница 4: ...and select the label to change e g 8 Installer Code 000 001 to program the label for zone 01 2 Press to open the Select Options menu 3 Press again to select the Words option 4 Enter the 3 digit number corresponding to a word see Words table below or use the scroll keys to view words in the library 5 Press to select the word 6 To add another word repeat the above procedure from step 2 7 To add a sp...

Страница 5: ...lost or no longer needed 1 Enter 5 and an access code with the supervisor attribute enabled 2 The keypad will display the user number and include the letter T if a prox tag is programmed 3 Scroll to Press for Prox Tag and press the key 4 The keypad will read Press To Delete Tag 5 After pressing the message Tag Deleted Successfully appears NOTE User codes can only be deleted individually NOTE User ...

Страница 6: ...ommand Output 4 07 System Test 25 28 For Future Use 08 For Future Use 29 Bypass Group Recall 09 Night Arm 30 Quick Bypass 10 For Future Use 31 For Future Use 11 Away Arm no Entry 32 For Future Use 12 Global Stay Arm 33 Bypass Recall 13 Global Away Arm 34 For Future Use 14 Global Dis arming 35 For Future Use 15 For Future Use 36 Reactivate Stay Away and Night Zones Default Zone or PGM Number 00 I__...

Страница 7: ...Hardware and Digital Security Controls a division of Tyco Safety Products Canada Ltd DSC the manufacturer of the integrated security systems and the developer of the software and any related products or components HARDWARE which You acquired If the DSC software product SOFTWARE PRODUCT or SOFTWARE is intended to be accompanied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy...

Страница 8: ...RANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC DSC MAKES NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CH...

Страница 9: ... X Armed Chime Duress Garage Level Office Right System A Y Arming Closed East Gas Library OK Room Tamper B Z Attic Closet Energy Glass Light On Safe Temperature C Space Auxiliary Closing Enter Goodbye Lights Open Saver Test D Apostrophe Away Code Entry Gym Living Opening Schedule Time E Dash Baby Communicator Error Hallway Load Panic Screen To F _ Underscore Back Computer Exercise Heat Loading Par...

Отзывы: