12
Figure 2 - Wiring Diagram
GS3060 Wiring Diagrams
5
4
1
2
36
789
10
11
14
15
16
17
18
19
20
LE
LI
O1
O2
O3
O4
+OC
13
12
AS
L1
L2
L3
L4
12V
1K5
This
Connection
is
necessary
T I P
T I P
R I N G
R I N G
GS3060
12 13 TAMPER
9
PGM3
8
PGM2
19 20
+
DC IN -
11
AUX+
16 Z2
17 Z3
15 Z1
14 COM
10
PGM4
7
PGM1
6
COM
4 T1
5 R1
2 TIP
3 RNG
1
18 Z4
RJ-45
BA
TTER
Y
Sealed Rechargeable
12V / 1.2Ah
Typical batter
y charge: 30-50 mA
Recommended Model: 12V/1.2Ah or
12V/7Ah (for order code GS3060-RF only)
Batter
y not required
if JP3 is ON
9-14V
DC
/ *700mA (max)
Tamper
Output
Earth-ground
Ground wire from building electrical installation
Inputs to be connected
to dr
y contact outputs
from alarm control panel
}
GROUND CONNECTION
Tighten nut to break paint & make good connection to the cabinet.
Nut
Nut
Bolt
Lock washer
Lock washer
Star washer
Cabinet
Alarm Control P
anel with
Dialler Interface
(Supports Contact ID format)
Panel Aux P
ower
or External P
ower
Supply (13.8V
DC
required for normal, long-term operation)
Telephone Line
Connection
Super
vision
Relay
RM1-UL Installations RM1C-ULC Installations
W
ARNING:
Incorrect connections may result in PT
C failure or improper operation. Inspect wiring and ensure connections are correct befor
e turning on.
Connect relay contacts to a zone input on the alarm control panel for GS3060
troubles super
vision
(24hr
-type zone)
Optional
use of PGM
output (See
Programming)
W
ARNING!
HIGH VOL
TAGE. DISCONNECT AC
POWER & TELEPHONE LINES
PRIOR TO SERVICING
All circuits are classified for UL installations as P
ower Limited/Class II P
ower Limited except for the batter
y leads which are
not P
ower Limited. Do not route any wiring
over circuit boards. Maintain at least 1” (25.4mm) separation. A minimum 1/4” (6.4mm) separation must be maintained at all poin
ts between P
ower Limited wiring
and all other Non-P
ower Limited wiring. Route wires as indicated in the diagram.
NOTE: For ULC Commercial Fire and Burglar
y Installation requirements please refer to Figures 5, 6, 7 & 8 and to the ULC Install
ation Guide P/N 29002157R009.
(Use No. 26 A
WG wires for
the connection to PSTN)
*Refer to Jumper 3 section for current rating
For ULC Fire Monitoring installations fire alarm signals shall be sent
simultaneously over POTS line (using the dialler) and over the GSM
network (using GS3060). Connect alarm output from control panel (PGM)
to the input on the GS3060 that is programmed as a Fire Alarm Input.
Examples of Control Units/Subscribers Units or P
ower Supplies compatible
models: DSC PC1864, PC1832, PC1616, PC5204, etc.
DG009553
firealarmresources.com