8
Assembly Diagram
Front Loading Baffle Option
We have a front loading baffle as an option that can
be purchased separately.
1. You will need to remove hopper, baffle insulation
and baffles that were shipped with insert to install
front loading baffle.
2. To install front loading baffle you will want to stack
your three pieces of insulation on the right side
baffle piece that has the square stock welded to it.
Insulation belongs on top. Slide the right side baffle
with the insulation up and into the right side of
insert.
3. Now take left side baffle piece and slide it up in
beside right side baffle sliding your top return bend
over the square stock welded to the right side
baffle. This will interlock your right and left baffle
pieces.
4. Do not push baffle the whole way to the back of
insert yet.
5. Now slide your insulation across the
top from right to left. You should have
FP16 RBR
FP1
6-BB
I
7
3/4
x10
1/4
FP16 LBR
FP16 FLRBR
FP16 FLLBR
Hopper
three pieces of insulation beside each
other covering the top of the baffle.
Slide the top side of insulation under
return bend of baffle.
6. Push baffle back into position. Make
sure holes on bottom back corners of
baffle connect to square tubing at
back corners of firebox, this is very
important for the function of your
baffle.
Coal Hopper Standard Baffle
Coal Hopper Standard Baffle Insulation
FP16-BSI / FP16BBI
Coal Hopper Front Loading Baffle Insulation
Coal Hopper Front Loading Baffle
FP16
-BSI 5
1/2
x 18
3/4
FP1
6-B
SI
5
1
/
2
x 18
3
/
4