DryAIR Hose Reel II Скачать руководство пользователя страница 8

Safety Concerns

2-4

ECOTOXICITY:  Based largely or completely on information for similar material(s), i.e. propylene glycol.  Material is practically non-

toxic to aquatic organisms on an acute basis (LC50 greater than 100 mg/L in most sensitive species).

   Acute LC50 for fathead minnow (Pimephales promelas) is 46500-54900 mg/L.
   Acute LC50 for guppy (Poecilia reticulata) is greater than 10000 mg/L.
   Acute LC50 for water flea Daphnia magna is 4850-34400 mg/L.
   Acute LC50 for rainbow trout (Oncorhynchus mykiss) is 44 ml/L (about 44000 mg/L).

13. DISPOSAL CONSIDERATION 

(See Section 15 for Regulatory Information)

DISPOSAL:  DO NOT DUMP INTO ANY SEWERS, ON THE GROUND OR INTO ANY BODY OF WATER.  All disposal methods must

be in compliance with all Federal, State/Provincial and local laws and regulations.  Regulations may vary in different locations.

Waste characterizations and compliance with applicable laws are the responsibility solely of the waste generator.  THE DOW

CHEMICAL COMPANY HAS NO CONTROL OVER THE MANAGEMENT PRACTICES OR MANUFACTURING PROCESS OF

PARTIES HANDLING OR USING THIS MATERIAL.  THE INFORMATION PRESENTED HERE PERTAINS ONLY TO THE

PRODUCT AS SHIPPED IN ITS INTENDED CONDITION AS DESCRIBED IN MSDS SECTION 2 (Composition/Information on

Ingredients).

FOR UNUSED & UNCONTAMINATED PRODUCT, the preferred options include sending to a licensed, permitted:  recycler,

reclaimer, incinerator or waste water treatment system.

As a service to its customers, Dow can provide names of information resources to help identify waste management companies and

other facilities which recycle, reprocess or manage chemicals or plastics, and that manage used drums.  Telephone Dow’s Customer

Information Centre at 800-258-2436 or 989-832-1556 for further details.

14. TRANSPORT INFORMATION

DEPARTMENT OF TRANSPORT:

This product is not regulated by D.O.T. when shipped domestically by land

CANADIAN TDG INFORMATION:

For TDG regulatory information, if required, consult transportation regulations, product shipping papers, or your Dow representative.

15. REGULATORY INFORMATION 

(Not meant to be all-inclusive—selected regulations represented)

NOTICE:  The information herein is presented in good faith and believed to be accurate as of the effective date shown above.  However,

no warranty, express or implied is given.  Regulatory requirements are subject to change and may differ from one location to

another; it is the buyer’s responsibility to ensure that its activities comply with federal, state or provincial, and local laws.  The

following specified information is made for the purpose of complying with numerous federal, state or provincial, and local laws and

regulations.  See other sections for health and safety information.

U.S. REGULATION

SARA 313 INFORMATION:  To the best of our knowledge, this product contains no chemical subject to SARA Title III Section 313

supplier notification requirements.

SARA HAZARD CATEGORY:  This product has been reviewed according to the EPA “Hazard Categories” promulgated under

Sections 311 and 312 of the Superfund Amendment and Reauthorization Act of 1986 (SARA Title III) and is considered, under

applicable definitions, to meet the following categories:  Not to have met any hazard category.

TOXIC SUBSTANCES CONTROL ACT (TSCA):

All ingredients are on the TSCA inventory or are not required to be listed on the TSCA inventory.

STATE RIGHT-TO-KNOW:  The following product components are cited on certain state lists as mentioned.  Non-listed

components may be shown in the composition section of the MSDS.

REGULATORY INFORMATION:

CHEMICAL NAME

CAS NUMBER

LIST

1, 2-PROPANEDIOL

00057-55-6

PA1

PA1=Pennsylvania Hazardous Substance (present at greater than or equal to 1.0%).

OSHA HAZARD COMMUNICATION STANDARD:
       This product is not a “Hazardous Chemical” as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.

CANADIAN REGULATIONS

WHMIS INFORMATION:  The Canadian Workplace Hazardous Materials Information System (WHMIS) classification for this

product is:  This product is not a “Controlled Product” under WHMIS.

16. OTHER INFORMATION

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) RATINGS:

Health

0

Flammability

1

Reactivity

0

MSDS STATUS:  Revised Section 16.

* or ® Indicates a Trademark of The Dow Chemical Company

The Information Herein Is Given In Good Faith, But No Warranty, Express or Implied, Id Made.  Consult The Dow

Chemical Company For Further Information.

Содержание Hose Reel II

Страница 1: ...5 DRYAIR INC 606 Highway Drive St Brieux SK Canada SOK 3V0 Tel 306 275 4848 1 888 750 1700 Fax 306 275 4664 dryair dryair ca DRYAIR INC 1095 N Main Street Bowling Green Ohio USA 43402 Tel 419 354 8546 1 866 354 8546 Fax 419 354 9706 dryair dryair us ...

Страница 2: ...Data Sheet 2 2 Material Safety Data Sheet 2 5 Introduction 3 1 Operating Features 3 1 Drive Features Power Requirements 3 1 Reel Capacities 3 1 Transportation Storage 3 1 Setup Operation 4 1 Manual Controls 4 1 Spool Rotational Speed 4 1 Automatic Controls Settings 4 2 Mechanical Drive Components 4 3 Maintenance 5 1 Altivar 11 AC Drive 5 1 Auto feed Control 5 2 Electric Motor 5 2 GearBox 5 2 Torqu...

Страница 3: ...es inconvenience and or replacement equipment rental cost Maintenance repair or service items not related to warrantable defects Loss or damage during shipping Failure resulting from lack of or improper maintenance Damage caused by operator abuse negligence or improper operation Damage resulting from improper voltage supply Damage from improper installation Installation done by other than the manu...

Страница 4: ...0 1700 Each warranty claim should only refer to one Serial or Production Schedule numbered unit Warranty parts are to be tagged with warranty claim number When claiming for warranty labour the allowable warranty labour rate will be 45 00 hour The factory reserves the right to adjust the number of hours claimed where deemed necessary The factory may at times specify allowable labour for certain war...

Страница 5: ...en working with heat transfer fluid DOWFROST HTF BOSS CHILL PG Fluid handling precautions Ventilation Good general ventilation should be sufficient for most conditions Respiratory protection No respiratory protection should be needed Skin protection For brief contact no precautions other than clean body covering clothing should be needed Use impervious gloves when prolonged or frequently repeated ...

Страница 6: ... adverse effects on the mother should have no effect on the fetus REPRODUCTIVE EFFECTS In animal studies has been shown not to interfere with reproduction 4 FIRST AID EYE Flush eyes with plenty of water SKIN Wash off in flowing water or shower INGESTION No adverse effects anticipated by this route of exposure incidental to proper industrial handling INHALATION Remove to fresh air if effects occur ...

Страница 7: ...VITY CHEMICAL STABILITY Stable CONDITIONS TO AVOID Avoid temperatures above 121 C 250 F Product can decompose at elevated temperatures INCOMPATIBILITY WITH OTHER MATERIALS Avoid contact with oxidizing materials HAZARDOUS DECOMPOSITION PRODUCTS When available oxygen is limited as in a fire or heated to very high temperatures by hot wire or plate carbon monoxide and other hazardous compounds such as...

Страница 8: ... selected regulations represented NOTICE The information herein is presented in good faith and believed to be accurate as of the effective date shown above However no warranty express or implied is given Regulatory requirements are subject to change and may differ from one location to another it is the buyer s responsibility to ensure that its activities comply with federal state or provincial and...

Страница 9: ...HYSICIAN No specific antidote Treatment of exposure should be directed at the control of symptoms and the condition of the patient 5 FIRE FIGHTING MEASURES FLAMMABLE PROPERTIES Refer to section 9 PHYSICAL AND CHEMICAL PROPERTIES EXTINGUISHING MEDIA Water fog or fine spray Dry chemical fire extinguishers Carbon dioxide fire extinguishers Foam Do not use direct water stream May spread fire Alcohol r...

Страница 10: ...d PERSONAL PROTECTION RESPIRATORY PROTECTION Atmospheric levels should be maintained below the exposure guideline PROTECTION When respiratory protection is required for certain operations use an approved air purifying respirator In dusty or misty atmospheres use an approved particulate respirator EYE PROTECTION Use safety glasses OTHER PROTECTIVE EQUIPMENT No precautions other than body covering c...

Страница 11: ...IS MATERIAL THE INFORMATION PRESENTED HERE PERTAINS ONLY TO THE PRODUCT AS SHIPPED IN ITS INTENDED CONDITION AS DESCRIBED IN MSDS SECTION 2 Composition Information on Ingredients FOR UNUSED UNCONTAMINATED PRODUCT the preferred options include sending to a licensed permitted recycler reclaimer incinerator or other thermal destructive device As a service to its customers Dow can provide names of inf...

Страница 12: ...a HAZARD RATING SYSTEM NFPA rating for this product are H 0 F 0 R 0 The ratings are part of a specific hazard communication program and should be disregarded where individuals are not trained in the use of this hazard rating system You should be familiar with the hazard communication programs applicable to your workplace RECOMMENDED USES AND RESTRICTIONS Intended as a heat transfer fluid for close...

Страница 13: ...equency drive The vari able frequency drive is a phase converter 1 to 3 phase The reel motor is a 1 HP 3 phase continuous duty electric motor Drive and motor protection against inertial forces is provided by an adjustable torque limiter clutch located between the motor gear box and the reel spool The torque limiter clutch provides quick braking action less than half a revolution with a loaded reel...

Страница 14: ...e the auto feed arm to lift When the auto feed arm lifts an attached plunger disengages from a limit switch internal which in turn activates the reel Caution When NOT operating the reel put the toggle switch in the Off position to prevent accidental activation and possible injury When the hose reel is to be left unsupervised the power cord should be unplugged from the power supply Mode 2 LOAD When...

Страница 15: ...l control power that may be present servicing the drive controller WAIT 15 MINUTES for the DC bus capacitors to discharge Then follow the DC bus voltage measurement procedure beginning on page 5 of the ALTIVAR 11 Adjustable Speed Drive Controllers Start up Guide to verify that the DC voltage is less than 45 Vdc The drive controller LEDs are not accurate indicators of the absence of DC bus voltage ...

Страница 16: ...o not overfill or underfill with oil Injury to personnel unit or other equipment may result Oil should be changed with greater frequency if unit is used in severe environment dusty or high humidity WARNING Oil housing and other components can reach high temperatures during operation and can cause severe burns Use extreme care when removing lubrication plugs and vents while servicing the unit See M...

Страница 17: ... be checked twice per season see Maintenance section With prolonged use the two friction disks located on either side of the A plate sprocket will eventually show wear It is important that the torque limiter clutch is adjusted properly If the clutch slips too easily the spool will take too long to stop and hose will pile up on the reel If the clutch does not slip at all the protection on the Altiv...

Страница 18: ...connections with voltage present DO NOT short across terminals PA and PC or across the DC capacitors Install and close all covers before applying power or starting and stopping the drive controller Before servicing the drive controller Disconnect all power Place a DO NOT TURN ON label on the drive controller disconnect Lock the disconnect in the open position Disconnect all power including externa...

Страница 19: ... motor is not in prolonged contact with moisture during operation or storage Note This motor has no built in thermal protection Thermal protection is provided by the ALTIVAR 11 Drive Controller 2 access door 3 auto feed switch and plunger 2 1 3 1 3 2 DANGER WARNING Gear Box Oil housing and other components can reach high temperatures during operation and can cause severe burns Use extreme care whe...

Страница 20: ... to cause the clutch to just slip with full lifting force If the clutch does not slip or slips too easily refer to the torque adjust procedure below Torque adjust procedure Insure that the adjusting nut is in a finger tight position If the adjustment nut is tighter than finger tight loosen and complete previous step Match mark the adjusting nut with the hub Using a torque wrench tighten the adjust...