![DryAIR Hose Reel II Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/dryair/hose-reel-ii/hose-reel-ii_operators-manual_2533232016.webp)
Setup/Operation
4-3
Mechanical Drive Components
Access to the internal mechanical drive components is through the access door. This door must be removed.
Electric Motor
(5-1)
•
The electric motor used to drive the reel is manufactured by Marathon Electric.
•
No regular maintenance is required.
•
Make sure that, during operation or storage, the motor is not in prolonged
contact with moisture.
•
Refer to the chart “
Table 1- Electric motor features & data”,
below for motor
data.
Note:
This motor has no built-in thermal protection. Thermal protection is provided by
the “ALTIVAR 11 Drive Controller”.
6 - Hub City gear box
5 - Marathon electric motor
Table 1 - Electric motor features & data
Gear Box
(6-1)
Gear box specifications
•
HUB CITY - Series 260, Model 264 (FR-56C-70)
•
Worm gear speed reducer
•
60:1 gear reduction
•
5/8" input shaft size
•
1 1/8" output shaft
CAUTION
Do not operate the unit without ensuring it contains the correct amount of oil. Do not overfill or underfill with oil. Injury to personnel,
unit, or other equipment may result.
Oil should be changed with greater frequency if unit is used in severe environment (dusty or high humidity).
WARNING
Oil, housing, and other components can reach high temperatures during operation, and can cause severe burns. Use extreme care when
removing lubrication plugs and vents while servicing the unit.
See “Maintenance - Gear Box” section of the operators manual for Hub City Gear Box oil filling procedures, service & maintenance.
Model Number:
56T17F5310
Phase:
3
Catalog Number: G527
Volts:
208-230/460
Product Type:
SQ CAGE IND RUN Insulation Class:
B
Enclosure:
TEFC
F.L. Amps:
3.4-3.6/1.8
Frame:
56C
Duty:
CONTINUOUS
HP/KW:
1
Service Factor:
1.15
Frequency (HZ): 60
F.L. Eff.:
77
Speed (RPM):
1800
Bearing:
BALL/BALL
Mounting:
ROUND
Thermal Protection:
NONE
Motor Wt.:
26
Shaft Material:
STANDARD
Hazardous Location: NONE
Enclosure:
TEFC
Mounting:
ROUND
Frame:
56C
Electrical Type:
STANDARD
Frame Material:
Rolled Steel
Spaceheaters:
NONE
Shaft:
T
Orientation:
Horizontal
Grease:
STANDARD
Conduit Assembly:
F1
Product Feature
Mechanical Information
5-1
6-1