Safety Concerns

2-8

STATE/LOCAL

Pennsylvania (Worker and Community Right To Know Act):  Pennsylvania Hazardous Substances List and/or Pennsylvania
Environmental Hazardous Substance List:
The following product components are cited in the Pennsylvania Hazardous Substance List and/or the Pennsylvania Environmental
Substance List, and are present at levels which require reporting.
COMPONENT

CAS#

AMOUNT

Propylene glycol

57-55-6

96.0000 %

Pennsylvania (Worker and Community Right To Know Act):  Pennsylvania Special Hazardous Substances List:
To the best of our knowledge this product does not contain chemicals at levels which require reporting under this statute.

California Proposition 65 (Safe Drinking Water and Toxic Enforcement Act of 1986)
This product contains no listed substances known to the State of California to cause cancer, birth defects of other reproductive harm,
at levels which would require a warning under the statute.

California SCAQMD Rule 443.1 (South Coast Air Quality Management District Rule 443.1, Labeling of Material Containing Organic
Solvents).
VOC:

Vapor pressure 0.66 mmHg @ 20

°

C

1002 g/l VOC
1030 g/l less water and less exempted solvents

This section provides selected regulatory information on this product including its components.  This is not intended to include all
regulations.  It is the responsibility of the user to know and comply with all applicable rules, regulations and laws relating to the product being
used.

1 6 . OTHER INFORMATION

ADDITIONAL INFORMATION

Additional information on this and other Dow products may be obtained by visiting our web page at www.dow.com.
Additional information on this product may be obtained by calling Dow’s Customer Information Group at 1-800-258-2436 (U.S.) or
1-800-331-6451 (Canada)

HAZARD RATING SYSTEM

NFPA rating for this product are:  H - 0

F - 0

R - 0

The ratings are part of a specific hazard communication program and should be disregarded where individuals are not trained in the use
of this hazard rating system.  You should be familiar with the hazard communication programs applicable to your workplace.

RECOMMENDED USES AND RESTRICTIONS

Intended as a heat transfer fluid for closed-loop systems.
Dow recommends that you use this product in a manner consistent with the listed use.  If your intended use is not consistent with
Dow’s Stated use, please contact Dow’s Customer Information Group at 1-800-258-2436 (U.S.) or 1-800-331-6451 (Canada) for
more information.

REVISION

Version:

4.1

Revision:

05/09/2002

Most recent revision(s) are noted by the bold, double bars in the left-hand margin throughout this document.

LEGEND

Bacteria/NA

Non Acclimated Bacteria

F

Fire

H

Health

IHG

Industrial Hygiene Guidelines

N/A

Not available

NFPA

National Fire Protection Association

O

Oxidizer

R

Reactivity

TS

Trade secret

VOL/VOL

Volume/Volume

W

Water reactive

W / W

Weight/Weight

NOTICE:  Dow urges each customer or recipient of this MSDS to study it carefully and consult appropriate expertise, as
necessary or appropriate, to become aware of and understand the data contained in this MSDS and any hazards associated with
the product.  The information herein is provided in good faith and believed to be accurate as of the effective date shown above.
However, no warranty, express or implied, is given., Regulatory requirements are subject to change and may differ between
various locations.  It is the buyer’s/user’s responsibility to ensure that its activities comply with all federal, state, provincial or
local laws.  The information presented here pertains only to the product as shipped.  Since conditions for use of the product
are not under the control of Dow, it is the buyer’s/user’s duty to determine the condition necessary for the safe use of this
product., Due to the proliferation of sources for information such as manufacturer-specific MSDSs, Dow is not and cannot be
responsible for MSDSs obtained from any source other than Dow.  If you have obtained a Dow MSDS from a non-Dow source or
if you are not sure that a Dow MSDS is current, please contact Dow for the most current version.

Содержание 2000-0250

Страница 1: ...70 Oct 16 03 DRYAIR INC 606 Highway Drive St Brieux SK Canada SOK 3V0 Tel 306 275 4848 1 888 750 1700 Fax 306 275 4664 dryair dryair ca DRYAIR INC 1095 N Main Street Bowling Green Ohio USA 43402 Tel 4...

Страница 2: ...ed Heat Transfer 3 1 Passive Heat Transfer 3 2 Accessories 3 2 How the DRYAIR System Works 3 3 Setup 4 1 Positioning and Handling of Water Heater Module 4 1 Required Safety Clearances 4 1 Elevation Co...

Страница 3: ...es inconvenience and or replacement equipment rental cost Maintenance repair or service items not related to warrantable defects Loss or damage during shipping Failure resulting from lack of or improp...

Страница 4: ...1700 Each warranty claim should only refer to one Serial or Production Schedule numbered unit Warranty parts are to be tagged with warranty claim number When claiming for warranty labour the allowabl...

Страница 5: ...working with heat transfer fluid DOWFROST HTF BOSS CHILL PG Fluid handling precautions Ventilation Good general ventilation should be sufficient for most conditions Respiratory protection No respirat...

Страница 6: ...adverse effects on the mother should have no effect on the fetus REPRODUCTIVE EFFECTS In animal studies has been shown not to interfere with reproduction 4 FIRST AID EYE Flush eyes with plenty of wate...

Страница 7: ...vailable oxygen is limited as in a fire or heated to very high temperatures by hot wire or plate carbon monoxide and other hazardous compounds such as aldehydes might be generated HAZARDOUS POLYMERIZA...

Страница 8: ...and may differ from one location to another it is the buyer s responsibility to ensure that its activities comply with federal state or provincial and local laws The following specified information is...

Страница 9: ...HYSICIAN No specific antidote Treatment of exposure should be directed at the control of symptoms and the condition of the patient 5 FIRE FIGHTING MEASURES FLAMMABLE PROPERTIES Refer to section 9 PHYS...

Страница 10: ...PERSONAL PROTECTION RESPIRATORY PROTECTION Atmospheric levels should be maintained below the exposure guideline PROTECTION When respiratory protection is required for certain operations use an approv...

Страница 11: ...OR UNUSED UNCONTAMINATED PRODUCT the preferred options include sending to a licensed permitted recycler reclaimer incinerator or other thermal destructive device As a service to its customers Dow can...

Страница 12: ...als are not trained in the use of this hazard rating system You should be familiar with the hazard communication programs applicable to your workplace RECOMMENDED USES AND RESTRICTIONS Intended as a h...

Страница 13: ...he ideal way to heat and or dry enclosed structures Their compact and mobile design allows them to be positioned where required on the job site The efficient fan coil design provides a high rate of he...

Страница 14: ...store or deploy other distribution lines used in DRYAIR portable heating applications The reel can also be secured onto its own transport trailer The trailer s no clog opening directly under the hose...

Страница 15: ...ansfer fluid flows through the transfer coil where heat is transferred to the air being drawn through the coil by the fan The coil is specially designed for optimum heat transfer without adding any mo...

Страница 16: ...stem Consider cabinet positioning in relation to portable heat exchanger positioning Required Safety Clearances The water heater module is a heating appliance therefore safe heat and exhaust clearance...

Страница 17: ...ize will result in inadequate and inconsistent fuel delivery DRYAIR will not be responsible for faulty system operation if the recommended tank size is not used Connect the propane supply line to the...

Страница 18: ...pure Dowfrost HTF or Boss Chill PG heat transfer fluid used in the DRYAIR system is made up of a blend of 95 97 Propylene glycol 5 Dipotassium phosphate and deionized water see Safety Concerns section...

Страница 19: ...low Electrical Check Power up Make sure the gas supply is closed off and control panel toggle switchws are in the OFF position Supply power to the system Fluid Circulation System Start up The DRYAIR w...

Страница 20: ...o 3 4 full at all times during this process Note that there may be a certain amount of air in the system HTF levels may change as air is displaced from the system Add HTF fluid to maintain 1 4 to 3 4...

Страница 21: ...e switch 7 2 to the ON position All the indicator lights should be on except the operator light which will come on when the burner is on The spark igniter will immediately begin its attempt to light t...

Страница 22: ...ug in another portable heat exchanger fan Repeat the first 3 steps with another portable heat exchanger until the return temperature gauge 8 1 does not rise to above 130 F At this point the water heat...

Страница 23: ...If a and b check out the flow switch will need to be re calibrated or replaced No power at out going side of high limit switch Check for 24 volt power between letter C and 4 on the terminal strip If t...

Страница 24: ...ter heater cabinet Ventilate the water heater cabinet Find and correct the leak before turning on any power or trying to re light the water heater Soap test the union for leaks Check heat transfer flu...

Страница 25: ...awer If any parts of the burners or their retainers are damaged or worn replace them For water heaters out of service for more than 60 days disassemble and clean the pilot with a soft brush Make sure...

Страница 26: ...should be cleaned using warm water and a soft bristled brush Reassemble and ensure that all fittings are tight The extracted heat transfer fluid can be reused Air will have to purged from the system...

Отзывы: