Page 4
For technical questions, please call 1-888-866-5797.
Item 63324
Specifications
Electrical Rating
12VDC / 9.5A
Power Cord Length
7'
Maximum Flow @ 0’
290 GPH
Maximum Head lift @ 0 Flow
40′
Intake and Discharge Ports
3/4″ Garden Hose Thread
*Note:
For optimal performance, the intake hose (included) Inner Diameter (I.D.) must be at least 1/2″ and free of
air leaks. All joints and connections of the intake hose should be securely tightened to prevent air from entering the
intake side. Make sure the intake hose is free from kinks.
In addition, the height from the intake to the pump and then the height from the
outlet to the discharge will greatly impact pump performance.
Operation
After reading these instructions, consider the following points before starting the pump:
TO PREVENT FIRE, use in-line 10A
fuse on positive (+) wire.
NOTE:
For additional reference to the parts
mentioned in the following pages, refer to the
Assembly Diagram at the end of this manual.
NOTE: Place the pump on a stable level surface only.
Do not place the Pump on a
rounded
or uneven surface.
CONNECT
INTAKE HOSE
(INCLUDED)
HERE
CONNECT
DISCHARGE HOSE
(NOT INCLUDED)
HERE
Figure A
1. Turn the pump on its side and place 3-4 drops
of food grade vegetable oil or mineral oil into the
intake coupling. Failing to do so will reduce impeller
(4) life, which depends on lubrication. Pump is
self-priming within 30 seconds of starting up.
2. Connect the intake and discharge hoses firmly.
In the event of a leak, check that the washers
are good and the connections are tight.
3. Use included intake hose and strainer. Make the
outlet hose as short as possible. Prime the pump
by filling the inlet hose with water and put the open
end of the hose in the water you wish to pump.
4. Ensure the power switch is off, then connect the
power cords to the battery.
Connect the red power
cord first. Then connect the black power cord.
5.
DO NOT RUN THE PUMP DRY! If the pump
does not start to move water in 30 seconds
turn it off and recheck your work.
NOTE:
Using the included attachment, the
Pump will remove water down to 1/8″. Unplug
the Pump once 1/4″ water level is reached.