background image

Page 3

For technical questions, please call 1-888-866-5797.

Item 56599 
        

26.  Periodically inspect the pump and system 

components to ensure the pump suction screen 
is free of mud, sand, and debris.  Disconnect the 
pump from the power supply before inspecting.

27.  Follow all local electrical and safety codes, along 

with the National Electrical Code (NEC).  In 
addition, all Occupational Safety and Health 
Administration (OSHA) guidelines must be followed.

28.  The motor of this pump has a thermal protector that 

will trip if the motor becomes too hot.  The protector 
will reset itself once the motor cools down and an 
acceptable temperature has been reached.  The 
pump may start unexpectedly if it is plugged in.

29.  Before using the pump, check the hose for holes or 

excess wear, which could cause leaks, and ensure 
the hose is not kinked or making sharp angles.  A 
straight hose allows the pump to move the greatest 
amount of water quickly, and also check that all 
hose connections are tight to minimize leaks.

30.  This pump is made of high-strength, 

corrosion-resistant materials.  It will provide trouble-
free service for a long time when properly installed, 
maintained, and used.  However, inadequate 
electrical power to the pump, dirt, or debris may 
cause the pump to fail.  Please carefully read 
the manual and follow the instructions regarding 
common pump problems and remedies.

31.  This pump is fully automatic in operation. If 

the water level is over 2 in., the water detector 
senses water.  Then the control system built in 
the pump automatically starts the pump and the 
pump continues to run until water is pumped down 
to 3/4 in. deep, and then it stops.  If the water 
level is not over 2 in., the pump will not start.

32.  Electric shock hazard! GFCI receptacles will provide 

protection against line to ground faults only.  The 
ground fault receptacle does NOT limit the magnitude 
of fault current and will NOT prevent an electrical 
shock.  Replace damaged cord immediately.

33.  Risk of electric shock.  This pump has NOT 

been tested for use in marine areas.

34.  Do not move, position, retrieve, or carry pump 

using the power cord or the discharge hose, 
damage to the pump or power cord may occur. 
Use the handle supplied on the pump or attach a 
string to the strainer to position as instructed.

35.  The warnings, precautions, and instructions 

discussed in this instruction manual cannot cover all 
possible conditions and situations that may occur.   
It must be understood by the operator that 
common sense and caution are factors 
which cannot be built into this product, but 
must be supplied by the operator.

Fluid Type

The Pump is designed for use with water at a maximum temperature of 95° F (35°C) and minimum of 32° F (0° C).  
Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products. 

Содержание 56599

Страница 1: ...s manual and the receipt in a safe and dry place for future reference 19i When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2019 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express wr...

Страница 2: ...cations This unit is NOT designed for use in septic tanks or underground vaults to pump raw sewage or effluents NEVER use in hazardous or explosive locations 14 Do not pump flammable or explosive liquids such as oil gasoline kerosene ethanol etc Do not use in the presence of flammable or explosive vapors Using this pump with or near flammable liquids can cause an explosion or fire resulting in pro...

Страница 3: ...llow the instructions regarding common pump problems and remedies 31 This pump is fully automatic in operation If the water level is over 2 in the water detector senses water Then the control system built in the pump automatically starts the pump and the pump continues to run until water is pumped down to 3 4 in deep and then it stops If the water level is not over 2 in the pump will not start 32 ...

Страница 4: ... break down grounding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to a...

Страница 5: ... kinds 2 If the water level sinks too low any sludge on the surface will dry out and stop the pump from starting To help ensure the pump will start as required check the pump regularly with start up tests Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to a 120 VAC 60Hz GFCI protected circuit 2 Make sure that the plug and so...

Страница 6: ...Strainer attached to filter out debris and stabilize the pump Discharge Debris Strainer Switch Housing Base and Inlet Screen Latches Connecting Discharge Hose sold separately 1 If using a 3 4 hose screw one end of the hose to the Check Valve until tight To minimize leaks use a hose that has a 3 4 threaded connector and rubber gasket 2 If using a 1 1 4 discharge hose connect a 3 4 adapter sold sepa...

Страница 7: ...one end of the included 25 rope to the pump handle Secure with a knot 3 Lower pump with Debris Strainer attached in a low area where water accumulates Do not drop the pump into a depth of more than 13 or the automatic switch may not function properly Be sure pump sits fully upright 4 Secure the rope outside the water for easy access a Be careful not to pinch or damage the rope cord or hose b Place...

Страница 8: ...aches outlet without any strain to cord 5 Secure the end of the rope outside the water collection area for easy access 6 Place pump in the lowest spot on surface where water accumulates Be sure pump sits fully upright 7 To position pump on a surface you cannot walk on hold rope walk around parameter and gently pull pump with rope Be careful to guide hose and power cord as you position the pump 8 O...

Страница 9: ...st have contact with water to automatically start the pump 4 The pump will not run dry Once the pump detects that water is no longer being removed it will shut down automatically Note The pump must remain upright and level at all times for water detection to function properly Do not allow the pump to operate on its side or inverted The shaft seal depends on water for lubrication Allowing the pump ...

Страница 10: ...he motor from a locked impeller which can be caused by debris build up or a frozen impeller When the pump is activated and the impeller is detected to be locked the unit will automatically shut down to protect the motor from overheating Once the pump is able to operate correctly the pump will resume normal operation Troubleshooting Problem Possible Causes Possible Solutions Pump runs but delivers ...

Страница 11: ...EMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Part Description Qty 1 Shaft 1 2 Impeller 1 3 Diffuser 1 4 Screw 4 5 Base and Inlet Screen 1 6 Screw 3 7 Debris St...

Страница 12: ...damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchand...

Отзывы: