2. Faulty altimeter.
3.2.2 Bit Pattern All Zeros
Possible causes:
1. Altimeter not connected.
2. Altimeter switched off.
3. Altimeter strobe (transponder) input not grounded.
4. Faulty altimeter.
3.2.3 Stuck Digit in Bit Pattern
If one digit remains unchanged with changing pressure the possible causes would be:
1. Cable fault - check continuity (refer to Table
4).
2. Faulty altimeter.
Alt 5000 ft
Aim 5000<
D2 to C4>00000000000
CODE ENCODER ERROR