![Dru ART 10-01 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/dru/art-10-01/art-10-01_instructions-for-installation-and-operation-manual_2532927015.webp)
English
operatInG InstructIons dru-art 2 – 6
The buttons to operate the appliance have been placed
behind the flap on the heater front.
Lighting
Press and hold button A (with the
symbol ). Press the ignition but-
ton E (with the symbol
) once
or twice to light the pilot burner.
Check that the pilot flame is alight
(behind the glass on the front).
Once the pilot light is burning, hold
button A for another 10 seconds.
Then release button A and check
that the pilot light is still burning.
The main burner could be ignited
by the pilot light immediately after
button A has been released,
depending on the thermostat setting,
button D, and the room temperature.
Temperature control
The thermostat setting, button D, will determine the
temperature in the room. Setting 7 - with ‘7’ opposite the
indicator (C) - will give the highest temperature and set-
ting 1 the lowest. The thermostat regulates the heater in
modulation between hIGh and LOW burner settings and,
if only a little warmth is required, between LOW and N.
The thermostat automatically keeps the room at the
required temperature.
There is absolutely no objection to the appliance staying
on overnight, it is fully protected.
The thermostat has a frost-protection setting. This is
setting N on the thermostat control D. If the ambient
temperature drops below 10 ºC, the valve will automati-
cally open; the heater will then heat the room to 10 ºC.
If this is not required, the heater should be switched off.
Switching off
Press button B (with the symbol o ). The gas supply to
both the main and the pilot burners is then switched off.
operatInG InstructIons
dru-art 8 and 10
The buttons to operate the appliance have been placed
behind the flap on the righthand side of the heater front.
Lighting
Press button A and turn to the left
towards the small flame .
At
the heater will ignite. Check
if the pilot light burns behind the win-
dow. If the pilot burns, keep
button A pressed fully down for
another 5 seconds. Then release
button A and check if the pilot light
keeps burning. Now turn button A
towards the big flame
. This will open the main valve
of the regulation block.
Temperature control
By turning control button B to the left (to mark 7), the
set temperature will rise, by turning the button to the
right (towards mark 1), the set temperature will fall. The
thermostat regulates modulatingly between full power
setting and low power setting and keeps the room at the
temperature set by you. The heater can be kept burning
uncontrolled as it is fully protected.
Pilot light setting
When the heater is not in use, but the pilot light has to
be kept burning, button A can be turned towards the
small flame. In this way, the gas supply to the main burner
will be turned off.
Switching off
Turn button A towards the “0” setting. The gas supply to
the burners will then be turned off.
OPERATING INSTRUCTIONS
E
B
A
C
D
A
B
DRU - ART
13
Содержание ART 10-01
Страница 10: ...8 ...
Страница 18: ...16 ...
Страница 26: ...24 ...
Страница 34: ...32 ...
Страница 42: ...40 ...
Страница 50: ...48 ...
Страница 59: ...DRU ART fig 1 DRU ART 2 fig 2 DRU ART 2 fig 3 DRU ART 3 4 fig 4 DRU ART 3 4 57 ...
Страница 62: ...60 fig 11 DRU ART 5 6 8 10 fig 12 DRU ART 5 6 8 10 ...
Страница 64: ...2 1 3 4 5 6 7 7 6 5 4 3 2 1 3 711 Fig 13 62 7 2 4 5 6 1 3 38c 927 Fig 14 ...
Страница 65: ...DRU ART 63 5 4 3 2 38c928 4 3 2 1 7 6 5 Fig 15 ...
Страница 67: ...DRU ART 65 ...
Страница 68: ......