5.4 PRECAUTIONS TO BE USED WHEN CARRING OUT WIRING
There are no specific safety risks associated with this device. Use general precautions that you would use when
operating an electrical device. All wiring should be carried out by a qualified electrician.
Before wiring the panel ensure correct voltage as indicated on the product label.
Only perform wiring operations once you are sure power is off and cannot be accidentally switched on.
A circuit breaker that is easy accessible must be used in the wiring of the pump. Ensure the break contact has a
contact distance of at least 3 mm
When using the 12-24V AC device, the power must come from a transformer in compliance with prescription of IEC
62558-2-6
In case of connection to 230 V~ or 110 V~, the connections on M1 (power and pump) must have reinforced isolation
up to the terminal connections. The cable must be routed to avoid damage to the outer isolation sheaf.
It is advisable to use a fuse or a differential isolation to protect the device. The device should have a recommended
value of 0,03 Ampere with 1 milllisecond maximum activation time. isolation capability ≥ 10kV and nominal ln=6A.
It is good practice to use cable ties that can help prevent cables being torn
6. OPERATOR INTERFACE FRONT PANEL
6.1 LAYOUT AND STATUS TABLE OF VIP5 FRONT PANEL
VIP5 Condition
PUMP ON LED
CYCLE INPUT LED
ALARM LED
Alarm
OFF
ON
ON
Standby Phase
OFF
ON
OFF
Lubrication Phase/Cycle
ON
ON
OFF
Setup
OFF
OFF
ON
Product
Identification
Label(on side)
Shows parameter and values
during set-up, or status and
counters during normal
operation.
BACK
:
Previous Parameter or Setting
Decrease displayed value
NEXT
:
Next Parameter or Setting
Increase displayed value
Alarm LED
Hardware Reset Button
Status and
description.
Cycle
status LED
Shows cycle
control input
condition
Pump ON LED:
Pump ON
Pump OFF
Stand by
OK
:
Exit from setup menu saving
changes
ESC
:
Exit from setup menu
without
saving changes
MODE
(SET):
Change Value for selected parameter