5
AIR CHARACTERISTICS
Characteristic
Requirement
Pressure at point of connection
Min. 6 Bar
Max. quantity of particles in suspension
15 mg/Nmc
Max. diameter of particles
0.05
Dew point
2° C
Max. quantity of oil in suspension
5 mg/Nmc
Whenever not utilizing natural base oils compatible with existing health regulations, it is necessary to
adjust the mixer pressure so as to avoid the formation and dispersion of oil mist into the environment.
The mixing pressure is indicatively between 1 and 2.5 Bar.
8. CONTRAINDICATIONS
The VIP4Tools
panel does not have any particular contraindications except for the following points:
•
The operator coming into contact with fluid due to breakage/opening of supply tubing.
•
The operator must be furnished with suitable personal protection clothing/equipment (part VIII –
626 [Safety at Work legislation]).
•
Abnormal posture.
•
Take note of the indications shown in
paragraph 10.2.
•
Contact with oil during filling/maintenance.
•
The operator must be furnished with suitable personal protection clothing/equipment (part VIII –
626 [Safety at Work legislation]).
•
Use of unsuitable lubricants.
Main inadmissible fluids.
Fluid
Danger
Lubricants with abrasive additives
High wear rate of contacted parts
Lubricants with silicon based additives
Seizure of the pump
Petrol – solvents – flammable liquids
Fire – explosion – damage to seals
Corrosive products
Corrosion of the pump– injury to persons
Water
Oxidation of the pump
Food substances
Contamination of the substances themselves
9. INSTALLATION
9.1 UNPACKING
Once a suitable location has been identified for the installation, open the package and remove
the equipment. Check that the VIP4Tools has not sustained damage during transport and
storage.
The packaging material does not require any special disposal precautions, not being in any
way dangerous or polluting.
9.2 MOUNTING THE VIP4Tools PANEL
Provide adequate space for the installation, leaving a minimum room of 100 mm around the
panel. Mount the VIP4Tools panel at shoulder height to avoid unnatural posture or the
possibility of sustaining impacts. Do not install the VIP4Tools in particularly aggressive or
explosive/flammable environments or on components subject to vibration.
Only use the supplied mounting bracket with N° 2 holes for Ø6 mm bolts.