9. MAINTENANCE PROCEDURE
To facilitate maintenance it is suggested that the pump be installed in an easily accessible location.
Provide users with the necessary personal protective clothing to avoid any contact with lubricant.
Once accurately set by Dropsa, the pump does not require any maintenance.
It is recommended the use of pure lubricants and a periodical accurate cleaning of pump components.
Dismantling has to be carried out as following:
1. There is a grease pushing spring. Before dismantling the reservoir, it has to be emptied of its content.
2. Discharge the supply pressure.
3. Disconnect fitting from the pump.
4. Unscrew fixing screws and then dismantle the reservoir keeping a lot of attention to the grease pushing
spring (the spring could be charged. If so, remove the residual lubricant).
5. Remove the pump and the filters.
6. Unscrew the pump pneumatic cylinder keeping a lot of attention to the charge of the spring. After this, it
is possible to slip off pumping group components.
In this way it is possible to free every pump component, remove and clean them.
Before mounting, each component has to be washed in oil and lubricate.
The following routine operations should be performed:
Operation
Interval (in hours)
Check correct lubrication function of the pump
100
Lubricant level
200
Clean the suction and re-filling filters
400
Clean the bottom of the oil reservoir from any dirt or particle deposits 600
The unit does not require any special tooling to operate or maintain it. It is recommended that suitable protective
clothing (including gloves and safety glasses) are worn when maintaining the unit in order to avoid hazards to
equipment or persons.
Be sure that all electrical and pressurized hydraulic components are disconnected prior to any
maintenance.
10. DISPOSAL
During maintenance or disposal of the machine care should be taken to properly dispose of environmentally
sensitive items such as oils or other lubricants. Refer to local regulations in force in your area.
When disposing of this unit, it is important to ensure that the identification label is also destroyed.
11. ORDERING INFORMATION
Ordering instructions
Code
Technical Characteristics
3413050
Pneumatic pump R=50:1 Reservoir 2 Kg (4.4 lb.)
3132671
Gasket replace kit
3132585
Pump delivery adjustment kit