background image

 

 

    

6

9. MAINTENANCE PROCEDURE

 

To facilitate maintenance it is suggested that the pump be installed in an easily accessible location. 
Provide users with the necessary personal protective clothing to avoid any contact with lubricant. 
Once accurately set by Dropsa, the pump does not require any maintenance. 
It is recommended the use of pure lubricants and a periodical  accurate cleaning of pump components. 
Dismantling has to be carried out as following: 
 

1.  There is a grease pushing spring. Before dismantling the reservoir, it has to be emptied of its content. 
2.  Discharge the supply pressure. 
3.  Disconnect fitting from the pump. 
4.  Unscrew fixing screws and then dismantle the reservoir keeping a lot of attention to the grease pushing 

spring (the spring could be charged. If so, remove the residual lubricant). 

5.  Remove the pump and the filters. 
6.  Unscrew the pump pneumatic cylinder keeping a lot of attention to the charge of the spring. After this, it 

is possible to slip off pumping group components. 

 
In this way it is possible to free every pump component, remove and clean them.  
Before mounting, each component has to be washed in oil and lubricate.  
 
 
 
The following routine operations should be performed:  
 

Operation   

Interval (in hours) 

Check correct lubrication function of the pump 

100 

Lubricant level 

200 

Clean the suction and re-filling filters 

400 

 

Clean the bottom of the oil reservoir from any dirt or particle deposits  600 

 
The unit does not require any special tooling to operate or maintain it. It is recommended that suitable protective 
clothing (including gloves and safety glasses) are worn when maintaining the unit in order to avoid hazards to 
equipment or persons. 

 

Be sure that all electrical and pressurized hydraulic components are disconnected prior to any 
maintenance. 

 

 
 
10. DISPOSAL  

 

During maintenance or disposal of the machine care should be taken to properly dispose of environmentally 
sensitive items such as oils or other lubricants. Refer to local regulations in force in your area.  
When disposing of this unit, it is important to ensure that the identification label is also destroyed. 

 

 
 
11. ORDERING INFORMATION  

 

 

Ordering instructions 

 

Code 

Technical Characteristics 

3413050 

Pneumatic pump  R=50:1  Reservoir 2 Kg (4.4 lb.)  

3132671 

Gasket replace kit 

3132585 

Pump delivery adjustment kit 

 
 
 
 
 
 

Содержание LOCOPUMP

Страница 1: ...TECHNICAL CHARACTERISTICS 5 PUMP COMPONENTS 6 UNPACKIGING AND INSTALLING THE PUMP 7 PUMP OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDL...

Страница 2: ...with valve UNI 7663 shape A 1 8 NPT Lubricant outlet G 1 4 bsp Compressed air inlet G 1 8 bsp compression cone seating 6 mm 0 2 in tube Cartridge shaped filter positioned at the grease gun inlet Elec...

Страница 3: ...onfiguration is N C 6 UNPACKING AND INSTALLING THE PUMP WARNING The unit can only be opened and repaired by authorized Dropsa personnel 6 1 UNPACKING Once a suitable location has been found to install...

Страница 4: ...aulic connectors are placed on the front face of the pump body The pump outlets are threaded as standard with 1 4 BSP threads 6 5 SUPPLY CONNECTION Use a fitting of 1 8 BSP to connect the pump Dropsa...

Страница 5: ...ck set data on the panel Push the start button of the machine to which the pump is connected Check pump commissioning Ensure the machine is properly lubricated in the event of doubts contact the Drops...

Страница 6: ...nent remove and clean them Before mounting each component has to be washed in oil and lubricate The following routine operations should be performed Operation Interval in hours Check correct lubricati...

Страница 7: ...NDLING AND TRANSPORTATION Pumps are accurately packed and dispatched in cardboard containers During transportation and storage always maintain the pump the right way up as indicated on the box On rece...

Страница 8: ...ions has been carried out filling in checking lists provided and contained in the technical file Dropsa used two kind of checking lists The list of hazards according to the EN 1050 as it refers to EN...

Страница 9: ...aid receipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perf...

Страница 10: ...UMATIC PUMP 36003XX o Has been manufacturer in conformance with the European Community Directive relating to the harmonised standards of the member states relating to machine safety EMC 89 336 CEE and...

Страница 11: ...563 100 07 Fax 55 011 563 194 08 E mail salesbr dropsa com Dropsa S p A Via B Croce 1 20090 Vimodrone MI Italy Tel 39 02 250 79 1 Fax 39 02 250 79 767 E mail sales dropsa it Export E mail vendite drop...

Отзывы: