background image

 

 

13. HANDLING AND TRANSPORTATION 

 

Prior to shipping, the equipment is carefully packed in a cardboard package. During  transportation and 
storage, pay attention to the side on the  cardboard packing. On receipt, check that the packing is not 
damaged. Then, storage the machine in a dry location.    

 

As the panel is small and not heavy, it is not necessary the use of material handling equipment. Lift the 
equipment observing the right way up shown on the cardboard packing.

 

 

 

During storage, machine components can withstand temperatures –20 °C ÷ +50 °C (-4 °F ÷ +122 F°). 
However, in order to avoid damages, machine starting should occur at a minimum temperature of +5 °C 
(+41 °F). 

 

14. OPERATING HAZARDS

 

 

 

 

 
 
 
 

Power supply 

Any type of intervention must not be carried out before  unplugging the machine from power supply. Make 
sure that no one can start it up again during the intervention. All the installed electric and electronic equipment, 
reservoirs and basic components must be grounded. 

 

Inflammability 

The lubricant generally used in lubrication systems is not normally inflammable. However, it is advised to avoid 
contact with extremely hot substances or naked flames.   

                
Pressure 

Prior to any intervention, check the absence of residual pressure in any branch of the lubricant circuit as it may 
cause oil sprays when disassembling components or fittings.  

 

Noise  

Pump does not produce excessive noise, less than 70 dB(A). 

 
WARNING:  

Empty the reservoir, before the replaicing of the mini-pumps. 

 

 

15. PRECAUTIONS 

 

No particular operating hazards characterize 

VIP4Tools/Oil Panel

, except for the following precautions: 

• 

Operator’s contact with fluid in case of piping breaking/opening or contact with oil during filling 
up/maintenance. The operator must be provided with suitable personal protective clothing (tit. VIII – 
626). 

• 

Unnatural posture. 

• 

Use of incompatible lubricant. 
 

                    Main unauthorized fluids:

       

                                                  

 

 

                                 

 

 
 
 
 
 

 
 
 

WARNING:  It is necessary to carefully read about the instructions and the risks involved in

the use of lubrication machines. The operator must know the machine
functioning through the User and Maintenance Manual. 

Fluids 

Dangers 

Lubricants containing abrasive components 

Premature wear of pump 

Lubricants containing silicon 

Pump failure 

Petrol – solvents – inflammable liquids 

Fire – explosion –seal damage 

Corrosive products 

Pump damage - danger to persons 

Water Pump 

oxidization 

Food Products 

Contamination of the product 

Содержание 3135059

Страница 1: ...THE PANEL 7 MACHINE OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING HAZARDS 15 PRECAUTIONS 16 WARRANTY INFORMATION 17 DECLARATION OF COMPLIANCE WITH STANDARDS 18 DROPSA LOCATIONS Manual drafted in compliance with C2041IE WK 23 04 EC Directive 98 37 Annex I paragraph 1 7 4 http www dropsa com Manufactu...

Страница 2: ...and is characterised by compactness The system consists in mini pumps from 1 to 4 pneumatically driven from sub bases Mini pumps flowrate can be manually adjusted to satisfy any need 0 30mm Available in several versions from 1 to 4 points of lubrication 3 PRODUCT MACHINE IDENTIFICATION Machine identification yellow label is located on the frontal side of the reservoir and contains product serial n...

Страница 3: ...ps sub base different for the number of mini pumps and consequently of lubrication points Mini pumps from 1 to 4 provided with a cap to adjust flowrate SAMBA level sensor which indicates lubricant minimum level via a N O electric contact To reverse N O to N C please contact Dropsa Eng Dept AIR SUPPLY INLET FOR PUMP DRIVE LUBRICANT OULETS CAPS TO ADJUST LUBRICANT FLOWRATE 0 30 mm AIR 5 8 BAR AIR DI...

Страница 4: ...nit in aggressive or explosive inflammable environments or on vibrating surfaces To install the panel use only the supplied bracket provided with two holes for screws Ø6mm Ø 0 23 in see Dimentions ch 12 6 3 INSTALLING MINI PUMPS ON THE SUB BASE Mini pumps are assembled to sub base by means of two fixing screws Be careful to correctly posistion o rings between mini pumps and sub base as shown in th...

Страница 5: ...cation is carried out correctly 7 2 1 Mini pumps flowrate Flowrate mm stroke Stroke mm in 30 6 5 0 25 25 5 5 0 21 20 4 5 0 17 15 3 5 0 13 10 2 5 0 09 5 1 5 0 05 0 Cap totally unscrewed 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE This panel has been designed and constructed to require a minimum maintenance Anyway it is recommended To keep the unit clear and periodically to check pipe joints to readil...

Страница 6: ...ION 1524431 Sub base for 1 mini pump 1524428 Sub base for 2 mini pumps 1524429 Sub base for 3 mini pumps 1524430 Sub base for 4 mini pumps 3103116C Pneumatic mini pump 2 screws 14067 3130139 Oil refilling filter 1655583 Samba Level 3044338 Reservoir 1 litre 0 22 gals 11 3 ACCESSORIES PART N DESCRIPTION 5717300 Flexible piping Ø4 mm Ø 0 15 in 5717301 Flexible piping Ø6 mm Ø 0 23 in 2049008 Nylon br...

Страница 7: ...7 12 DIMENSIONS A Weight N mini pumps mm in Kg lb 1 265 10 4 1 85 4 2 285 11 2 2 2 4 8 3 305 12 2 55 5 6 4 325 12 8 2 9 6 4 ...

Страница 8: ...d contact with extremely hot substances or naked flames Pressure Prior to any intervention check the absence of residual pressure in any branch of the lubricant circuit as it may cause oil sprays when disassembling components or fittings Noise Pump does not produce excessive noise less than 70 dB A WARNING Empty the reservoir before the replaicing of the mini pumps 15 PRECAUTIONS No particular ope...

Страница 9: ...paid receipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such necessary product repairs or replace such product s at our expense Dropsa reserves to right to charge an administration fee if the product s returned are found to be not defective This limit...

Страница 10: ...d in conformance with the EUROPEAN COMMUNITY DIRECTIVE relating to machines 98 37 EC low voltage BT 73 23 EEC o Has been manufactured in conformance with the following technical harmonised standards and specification EN 292 1 2 EN 1050 EN 982 EN 11200 EN 60947 EN 894 1 2________________________________________ Technical Director W Divisi Product Manager Name DROPSA SpA Company January 2002 Signatu...

Страница 11: ...Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa S p A Via B Croce 1 20090 Vimodrone MI Italy Tel 39 02 250 79 1 Fax 39 02 250 79 767 E mail sales dropsa it Export E mail vendite dropsa it National Polydrop S A Av Fabregada 26 Pje Est 2 08907 L Hospitalet de LLobregat Barcelona Spain Tel 34 93 260 22 50 Fax 34 93 260 22 51 E mail sales dropsa it Dropsa Gmbh Volmerswerther...

Отзывы: