6.2 INSTALLATION 

 

Allow sufficient space for the installation, leaving minimum 100 mm (3.94 in.) around the pump. 

Place the pump at shoulder height to avoid an unnatural posture or possibility of sustaining impacts. 

 

Hyd-min PUMP

 must be installed vertically inserting the shank into the grease barrel until it reaches the bottom of the drum.  

 

It is possible to use the threaded fixing lockring for mounting in a 2" threaded hole (standard for trade drums). To adjust the 

hole height is enough unscrew the grains radially existing at the lockring, placing them at desired height and tighten the grains 

previously unscrewed. The fixing lockring is equipped by gasket for pressurize the tank (see reservoir features). 

 

Purchasing separately the pump and the follower plate with cover, is necessary to remove the fixing lockring by the stem, insert 

the cover and follower plate in the correct direction ( lip seal upward) and then insert the limit ring at the stem extremity. 

 

 

 

 

 

 

6.3 HYDRAULIC CONNECTIONS   

 

Ensure that all pipes and fittings are suitable for the pressure and the fluid used and connect the oil supply to the pump 

hydraulic cylinder and the flow barrel pump to the system.

 

 

The user may opt to use the following hydraulic changeover valves:  

Valves usually used are: 

 

Automatic hydraulic change-over:

 when 

the pilot pressure of the valve is reached point the valve automatically switches 

the direction of the oil from P-A to P-B and vice-versa (as a diagram show in Paragraph 2).

 

 

Electrical Inverter: 

the electrically controlled valve switches the flow of oil from P-A to P-B and vice-versa. The user must 

not use a operating  frequency less than 0.5 sec per change-over. 

 

 

Always ensure the integrity of pipes and fittings before operating the pump. 

 

 

 

 

 

 

7. INSTRUCTIONS FOR USE 

 

7.1 

ACTIONS TO BE MADE BEFORE STARTING

  

 

 

The unit should be operated only by qualified personnel. 

 

The pump should never be used in hazardous environments or immersed in any fluids.  

 

Always use safety gloves and glasses when handling lubricants.  

 

Do not use lubricants that may contains substances incompatible with NBR Rubber,  if in doubt consult the Dropsa 

technical department which will provide a detailed documentation about lubricants recommended. 

 

Follow all health and safety rules required by law.  

 

Always use pipes suitable for operating pressures. 

 

Check the integrity of the pump; ensure there is no physical damage. 

 

Check that pump pressure supply is correct. 

 

Fill the Oil reservoir with suitable lubricant. 

 

Ensure that the pump is within the specified ambient temperature.  

 

Check electrical and hydraulic connections have been carried out correctly. 

 

7.2 PUMP USE 

 

 

Switch on the pump by pressing the start button on the control system in use;  

 

Check that the pump is running;  

 

Adjust the pressure by pass to the desired setting;  

 

Verify that lubricant is correctly dispensed the lubrication system is functioning correctly.  

Contact Dropsa for technical items regarding the type of valve to be used.

 

 

WARNING: 

 

When using a grease follower plate, it is recommended to check for crushes on drum sides which 

could prevent the follower plate from descending into the barrel. Use only intact drums with no defects. 

 

 

Содержание 0234560

Страница 1: ...NS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT 14 PRECAUTIONS FOR USE 15 OPERATIONAL HAZARDS Manual compiled in a...

Страница 2: ...ations Manufactured in high quality carbon steel the pump design features allow it to work with viscous lubricants without any additional complicated priming procedures The pump when combined with a s...

Страница 3: ...duct for your application 4 TECHNICAL FEATURES GENERAL CHARACTERISTICS Pumping System Hydraulically activated Piston mechanism Lubricant Outlet Port 3 8 BSP UNI ISO 228 1 Return Line Port 1 4 BSP UNI...

Страница 4: ...tant to inspect the pump to ensure that there has been no damage during transportation The packaging material used does not require any special disposal procedures You should refer to you regional req...

Страница 5: ...l Inverter the electrically controlled valve switches the flow of oil from P A to P B and vice versa The user must not use a operating frequency less than 0 5 sec per change over Always ensure the int...

Страница 6: ...substances and should be disposed of following local regulations including any recycling information indicated on the components themselves Upon demolition of the machine you must destroy the identifi...

Страница 7: ...1141607 FOLLOWER PLATE 25KG D 320 1141602 FOLLOWER PLATE 50KG D375 1141604 FOLLOWER PLATE 200KG D580 3005141 LOCK RING 0234570 HYD INVERT AUTOMATIC CETOP 3 0234571 ELE INVERT 24VDC CETOP 3 0234572 EL...

Страница 8: ...8 12 DIMENSIONS Dimensions in mm in...

Страница 9: ...p LUBRICANTS The following is a comparison table between NLGI National Lubricating Grease Institute and ASTM American Society for Testing and Materials for greases showing the permissible values for t...

Страница 10: ...g appropriate personal protective clothing and glasses Electrocution This can occur if the user does not securely connected the wires inside the terminal box Electrical connections must therefore be c...

Отзывы: