Drop BX-20-201 Скачать руководство пользователя страница 4

General recommendations 

INTRODUCTION

• In small facilities, with few filter elements, it is
recommendable to install a sustaining pressure
valve under the filtrate system, with the purpose of
guaranteeing sufficient pressure for the backwash
process of. This valve must go provided with a
control mechanism (electrical
or hydraulic) that manages its total opening during
the filtration process.
• In any case, whenever the installation does not
allow to maintain necessary the sufficient pressure
for the backwash one, it is advisable to place a
manual valve when coming out (of butterfly),
regulated properly to stabilize the pressure.

• With the purpose of eliminating the air that
could arrive at the filter elements, he is
recommendable to place a vent valve in an
advisable place of the system.
• In order to avoid the inverse flow, from the

• In order to avoid the inverse flow, from the
irrigation

towards

the

filtrate,

before

a

shutdown

of

the

pumping

system,

the

installation of a retention valve is advisable, in
cases in that the height waters down is greater
than where the
pressure system is located.
• With the purpose of being able to eliminate
the water of the system for operations of
maintenance one is due to have a purge valve.

• The use of satellites filters in the water
takings

of

the

irrigation

sectors

eliminates risks of cloggings of emitters.
These cloggings could be caused by the
grain

formation

by

agglutinations

of

dissolved substances that precipitate
throughout the conduction. Also risk of
clogging

by

a

possible

accidental

breakage of the conduction is run.
• As protection against overpressures
safety valves can be installed in the
system.

Содержание BX-20-201

Страница 1: ...Operating Instructions SYSTEM BX 20 201...

Страница 2: ......

Страница 3: ...stems need of a periodic maintenance revisions consumable replacements in function of the qualities of the waters and of the work conditions A competent technician should advise the selection of the s...

Страница 4: ...ble to place a vent valve in an advisable place of the system In order to avoid the inverse flow from the In order to avoid the inverse flow from the irrigation towards the filtrate before a shutdown...

Страница 5: ...size from fine to coarse causes premature clogging of the filter since even small particles which can be tolerated from the emitters are retained from the non uniform pores of the media Uniformity coe...

Страница 6: ...WATER OPERATING FLOW 12 m3 h CANAL WATER MAX OPERATING PRESSURE 8 bar MIN OPERATING PRESSURE 2 2 5 bar TOTAL FILTRATION AREA 0 40 m2 TOTAL REQUIRED SILICA SAND 260 Kg 10 BAGS INLET OUTLET 3 DN80 flan...

Страница 7: ...AC DP 1 pcs 7 METAL SUPPORT FOR CONTROLLER 1 pcs 8 AIR RELIEF VALVE 1 DOUBLE ACTION 1 pcs 11 SEALS 2 4 pcs 12 SEALS 3 1 pcs 13 BOLTS 5 8 x60 NUTS 20 pcs 14 METAL FLANGES MALE THREADED 2 4 pcs 15 RAKOR...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...ICATIONS Join the 3 screen filter to the outlet collector As soon as you finish the installation properly and according to the relative designs tighten all the bolts nuts so to secure the system Insta...

Страница 12: ...nage outlet clear at the beginning then dark and afterwards clear again At this moment the backflushing time is over 13 The time between cleanings starts when the backflushing is over and the successi...

Страница 13: ...ffusers are fitted at the lower side of the filtration chamber Screen filters are installed downstream to the system to retain any fine particles that may pass from the sand media filters IN CASE OF A...

Страница 14: ...h Upon receiving a command from the controller the backwash valve shuts off supply and opens drain Filtrated water from the other media units flows on the reversed direction and flushes out the entrap...

Страница 15: ...n which should be adapted accordingly Periodic time 4h and or at least once per day Flush time 120sec Dwell time 15sec PD switch 70kPa 0 7bar IT IS VERY IMPORTANT TO HAVE DOWNSTREAM PRESSURE IT IS VER...

Страница 16: ...bottom manhole Rinse thoroughly the inside surface of the filter Close the side gate with the cover and tighten properly Dismantle periodically the screen filters in order to clean the screen Open th...

Страница 17: ...it is so it is necessary interchange the contact base with other of the outlet Look the solenoids part and press attention at the impulse ones because they can suffer seizure 3 Water flushing out thr...

Страница 18: ...uch flow Decrease Excessive debris Regulate for more frequent cleanings Low pressure bad cleaning increase the pressure in the system Not the appropriate size of the filters Contact with the technical...

Страница 19: ...ILICA THE TYPE OF SILICA SAND YOU WILL USE IF YOU WILL USE SILICA SAND TYPE 1 2 SAND TYPE 1 2 2 4mm YOU MUST USE DIFFUSERS WITH SLOT 2 4mm YOU MUST USE DIFFUSERS WITH SLOT OPENING 0 5mm IF YOU WILL US...

Страница 20: ...CONTROLLER Please advise the attached documents of this manual at the end...

Страница 21: ...psi Minimum Operating Pressure 0 5 bar 8 psi End Connections Female Threaded 1 8 BSP Orifice Size 5 8 mm 0 226 Manual Override Auto Open Closed Voltage Available 24V AC 50 60 Hz DC Latching 9 40 volts...

Страница 22: ...3way BACKWASHING VALVES...

Страница 23: ...3way BACKWASHING VALVES...

Страница 24: ...3way BACKWASHING VALVES...

Страница 25: ...3way BACKWASHING VALVES...

Страница 26: ...NOTES...

Страница 27: ......

Отзывы: