background image

 

3

TECHNICAL SPECIFICATIONS 

 

 

SIBERIAN-1200

 

SIBERIAN-1600

 

SIBERIAN-2000

 

Combustion Type:

 

Wood Wood Wood 

Recommended Surface

 

600 à 1 200 ft

2

(56 à 112 m

2

900 à 1 600 ft

2

(84 à 149 m

2

1 000 à 2 000 ft

2

(93 à 186 m

2

Heating Capacity : 

E.P.A : 

36 000 BTU/h 

(10,5kW) 

40 000 BTU/h 

(11,7 kW) 

60 200 BTU/h 

(17,6 kW) 

 Real 

45 000 BTU/h 

(13,2 kW) 

70 000 BTU/h 

(20,5 kW) 

95 000 BTU/h 

(27,8 kW) 

Efficiency : 

73% 71,3% 72,2% 

Average Emission: 

6,5 g/h 

3,3 g/h 

3,8 g/h 

Colors :

 

Anthracite and 

burgundy 

Anthracite and 

burgundy 

Anthracite and 

burgundy 

Flue Pipe Diameter :

 

6’’ (152 mm) 

6’’ (152 mm) 

6’’ (152 mm) 

Chimney type :

 

2 100°F (650 °C) 

2 100°F (650 °C) 

2 100°F (650 °C) 

Minimum Chimney Height : 

12’ (3,66 m) 

12’ (3,66 m) 

12’ (3,66 m) 

Maximum Log Length :

 

16’’ (406 mm) 

18’’ (457 mm) 

19’’ (483 mm) 

Dimensions 

 

 

 

 Overall

 

W x D x H 

23 7/8 x 23 x 29 ¾’’ 

(607 x 584 x 756mm) 

W x D x H 

26 3/8 x 27 x 32 5/8‘’ 

(671 x 686 x 828mm) 

W x D x H 

30 x 29 ¼ x 34 ¼’’ 

(762 x 743 x 870mm) 

  Combustion Chamber :

 

   

Width x Depth : 

 
  

Volume 

 

18 x 14’’ 

(457 x 356 mm) 

1,5 pi

3

 (0,04 m

3

 

18 ¼ x 15 ¼’’ 

(464 x 387 mm) 

2,5 pi

3

 (0,07 m

3

 

22 ½ x 18’’ 

(572 x 457 mm) 

3,4 pi

3

 (0,09 m

3

  Door Opening :

 

   

Width x Height : 

 

15 ¼’’ x 7 ½’’ 

(387 x 191 mm) 

 

16 ¾ x 8 ¾’’ 

(425 x 222 mm) 

 

20 3/8 x 7 ¼’’ 

(518 x 184 mm) 

  Pyroceram Glass Door :  

   

Width x Height : 

 

15 ½’’ x 8 ½’’ 

(394 x 216 mm) 

 

17 x 10 ½’’ 

(432 x 267 mm) 

 

20 ½ x 8 ¾’’ 

(521 x 222 mm) 

Mass:

 

263 lbs ( 119 Kg) 

380 lbs (172 Kg) 

510 lbs (231 Kg) 

 

 

 

 

OPTIONS 

 

 

 

Blower 75 CFM (2,83 m

3

/min) with 

variable speed control

 

Yes Yes

 

Yes

 

Thermodisc 100-120

o

F (37-49

0

C). Yes

 

Yes

 

Yes

 

 

Содержание SIBERIAN 1200

Страница 1: ...PHASE II CERTIFIED WOODSTOVES V rified and tested following ULC S627 et UL 1482 Standards by Intertek Testing Services READ AND KEEP THIS MANUAL FOR REFERENCE Manufactured by STOVE BUILDER INTERNATION...

Страница 2: ...OR ADJUSTMENT 9 THE BENEFITS OF INSTALLING A BLOWER 10 INSTALLATION 11 POSITIONING THE STOVE 11 FLOOR PROTECTOR 12 CLEARANCES 13 REDUCED CLEARANCES 14 CHIMNEY 15 CHIMNEY CONNECTOR STOVE PIPE 16 TYPICA...

Страница 3: ...s not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even deat...

Страница 4: ...2 100 F 650 C Minimum Chimney Height 12 3 66 m 12 3 66 m 12 3 66 m Maximum Log Length 16 406 mm 18 457 mm 19 483 mm Dimensions Overall W x D x H 23 7 8 x 23 x 29 607 x 584 x 756mm W x D x H 26 3 8 x...

Страница 5: ...tove but only four will align with the pedestal 4 Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws 5 Slide the ash pan in position for D...

Страница 6: ...be installed according to figure 4 In both stoves the baffle brick must be pushed as close to the front as possible onto its metallic support The upper bricks 2 must lay on the vertical bricks 4 grove...

Страница 7: ...all the back bricks 6 x 4 1 2 x 9 4 Install the bottom bricks 4 x 4 1 2 x 9 2 x 6 x 7 5 Install the T shape support and the bricks 4 x 4 1 2 x 9 2 x 3 x 9 6 Install the baffle bricks 4 x 4 1 2 x 9 2 x...

Страница 8: ...s necessary to remove the two front secondary air tubes First place only one baffle brick and one white ceramic insulation Use the same method to put the other baffle brick and insulation Put back in...

Страница 9: ...of the tube are on the left side Insert one tube in the right side air channel and slide it to the right as much as possible Bring the left end of the tube aligned with the ring welded to the left ai...

Страница 10: ...sted periodically to provide an air tight fit To adjust Remove the lock pin spring pin by pulling and turning it using pliers wise grip Turn the handle counter clock wise one turn to increase pressure...

Страница 11: ...toward the front the blower enables you to extend the radiation power of your stove You can purchase this option through your DROLET dealer Make sure to specify this part number AC02050 You can also...

Страница 12: ...TEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in...

Страница 13: ...n inches beyond the front and eight inches beyond each side of the fuel loading and ash removal opening If there is a horizontal section of chimney connector the floor protector should go under it and...

Страница 14: ...wall pipe USA A B C D E F SIBERIAN 1200 17 12 5 8 8 10 7 22 4 17 9 20 20 22 4 19 4 SIBERIAN 1600 15 12 14 12 12 8 20 8 17 8 27 2 25 2 25 5 21 5 SIBERIAN 2000 15 10 10 8 7 5 21 3 16 3 24 9 22 9 22 1 20...

Страница 15: ...shield the clearances mentioned on the stove certification plate may be reduced as stated in the following table Reducing Clearances With Shielding TYPE OF PROTECTION Sides and Rear Back Top Sheet me...

Страница 16: ...draught effect your stove s performance is directly dependent on an adequate draught from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect...

Страница 17: ...installed horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney To insure a good draught the total length of the coupling pipe should never exceed 8 t...

Страница 18: ...TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY ROOF FLASHING 18 CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIELD Vertical installation 17...

Страница 19: ...MASONRY CHIMNEY Clay liner Thimble Clean out door 18...

Страница 20: ...FACTORY BUILT THIMBLE 19...

Страница 21: ...BRICK THIMBLE 20...

Страница 22: ...d Hemlock 17 Spruce 17 Pine 17 Bass 16 Low energy yield Fir 13 Data provided by Energy Mines and Resources Canada IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD STOVE The wood must...

Страница 23: ...achieve a medium burn rate Make sure that there s enough air circulation while curing the stove The odours could be smelled during the 3 or 4 first fires Never start your stove outside You will not b...

Страница 24: ...will be achieved according to control setting Low Medium Medium high High SIBERIAN 1200 full close 7 16 7 8 full open SIBERIAN 1600 full close 1 4 5 8 full open SIBERIAN 2000 full close 1 2 1 full ope...

Страница 25: ...ION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creosote The creosote vapours condense in the relatively cool...

Страница 26: ...away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the close container until all cinder...

Страница 27: ...alized product available in the stores where wood stoves are sold The glass should be washed only when cold GASKETING It is recommended that you change the door gasket which makes your stove door air...

Страница 28: ...ires the prior approval of the manufacturer Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the repla...

Отзывы: