24

RELOADING 

Once you have obtained a good bed of embers, you should reload the unit.  In order to do 
so, open the air controls to maximum a few seconds prior to opening the stove's door.  
Then proceed by opening the door very slowly; open it one or two inches for 5 to 10 
seconds, before opening it completely to increase the draught and thus eliminate the 
smoke which is stagnant in a state of slow combustion in the stove.  Then bring the red 
embers to the front of the stove and reload the unit. 

For optimal operation of your wood stove, we recommend you operate it with a wood load 
approximately equivalent to the height of fire bricks. 

It is important to note that wood combustion consumes ambient oxygen in the room .In the 
case of negative pressure, it is a good idea to allow fresh air in the room, either by opening 
a window slightly or by installing a fresh air intake system on an outside wall.  Refer to 
page 16 of the present manual. 

 

WARNINGS 
 

• 

N

EVER OVERFIRE YOUR STOVE

.  I

F ANY PART OF THE STOVE STARTS TO GLOW RED

OVER 

FIRING IS HAPPENING

. R

EADJUST THE AIR INTAKE CONTROL AT A LOWER SETTING

• 

T

HE INSTALLATION OF A LOG CRADLE IS NOT RECOMMENDED IN YOUR DROLET WOOD STOVE

• 

N

EVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX

 

CREOSOTE FORMATION AND NEED FOR REMOVAL 

When wood is burned slowly, it produces tar and other organic vapours, which combine 
with expelled moisture to form creosote.  The creosote vapours condense in the relatively 
cool chimney flue of a slow-burning fire.  As a result, creosote residue accumulates on the 
flue lining.  When ignited this creosote makes an extremely hot fire.  When burning wood, 
the chimney connector and chimney should be inspected at least once every two months 
during the heating season to determine if a creosote build-up has occurred. 

We strongly recommend that you install a magnetic thermometer on your smoke exhaust 
pipe, approximately 18" above the stove.  This thermometer will indicate the temperature 
of your gas exhaust fumes within the smoke exhaust system.  The ideal temperature for 
these gases is somewhere between 275

o

 F and 500

o

 F.  Below these temperatures, the 

build-up of creosote is promoted. Above 500 degrees, heat is wasted since a too large 
quantity is lost into the atmosphere. 

 

TO PREVENT CREOSOTE BUILD UP 

• 

Always burn dry wood.  This allows clean burns and higher chimney temperatures, 
therefore less creosote deposit. 

• 

Leave the air control full open for about 10 min. every time you reload the stove to 
bring it back to proper operating temperatures. The secondary combustion can only 
take place if the firebox is hot enough. 

• 

Always check for creosote deposit once every two months and have your chimney 
cleaned at least once a year. 

Содержание SIBERIAN 1200

Страница 1: ...PHASE II CERTIFIED WOODSTOVES V rified and tested following ULC S627 et UL 1482 Standards by Intertek Testing Services READ AND KEEP THIS MANUAL FOR REFERENCE Manufactured by STOVE BUILDER INTERNATION...

Страница 2: ...OR ADJUSTMENT 9 THE BENEFITS OF INSTALLING A BLOWER 10 INSTALLATION 11 POSITIONING THE STOVE 11 FLOOR PROTECTOR 12 CLEARANCES 13 REDUCED CLEARANCES 14 CHIMNEY 15 CHIMNEY CONNECTOR STOVE PIPE 16 TYPICA...

Страница 3: ...s not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even deat...

Страница 4: ...2 100 F 650 C Minimum Chimney Height 12 3 66 m 12 3 66 m 12 3 66 m Maximum Log Length 16 406 mm 18 457 mm 19 483 mm Dimensions Overall W x D x H 23 7 8 x 23 x 29 607 x 584 x 756mm W x D x H 26 3 8 x...

Страница 5: ...tove but only four will align with the pedestal 4 Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws 5 Slide the ash pan in position for D...

Страница 6: ...be installed according to figure 4 In both stoves the baffle brick must be pushed as close to the front as possible onto its metallic support The upper bricks 2 must lay on the vertical bricks 4 grove...

Страница 7: ...all the back bricks 6 x 4 1 2 x 9 4 Install the bottom bricks 4 x 4 1 2 x 9 2 x 6 x 7 5 Install the T shape support and the bricks 4 x 4 1 2 x 9 2 x 3 x 9 6 Install the baffle bricks 4 x 4 1 2 x 9 2 x...

Страница 8: ...s necessary to remove the two front secondary air tubes First place only one baffle brick and one white ceramic insulation Use the same method to put the other baffle brick and insulation Put back in...

Страница 9: ...of the tube are on the left side Insert one tube in the right side air channel and slide it to the right as much as possible Bring the left end of the tube aligned with the ring welded to the left ai...

Страница 10: ...sted periodically to provide an air tight fit To adjust Remove the lock pin spring pin by pulling and turning it using pliers wise grip Turn the handle counter clock wise one turn to increase pressure...

Страница 11: ...toward the front the blower enables you to extend the radiation power of your stove You can purchase this option through your DROLET dealer Make sure to specify this part number AC02050 You can also...

Страница 12: ...TEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in...

Страница 13: ...n inches beyond the front and eight inches beyond each side of the fuel loading and ash removal opening If there is a horizontal section of chimney connector the floor protector should go under it and...

Страница 14: ...wall pipe USA A B C D E F SIBERIAN 1200 17 12 5 8 8 10 7 22 4 17 9 20 20 22 4 19 4 SIBERIAN 1600 15 12 14 12 12 8 20 8 17 8 27 2 25 2 25 5 21 5 SIBERIAN 2000 15 10 10 8 7 5 21 3 16 3 24 9 22 9 22 1 20...

Страница 15: ...shield the clearances mentioned on the stove certification plate may be reduced as stated in the following table Reducing Clearances With Shielding TYPE OF PROTECTION Sides and Rear Back Top Sheet me...

Страница 16: ...draught effect your stove s performance is directly dependent on an adequate draught from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect...

Страница 17: ...installed horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney To insure a good draught the total length of the coupling pipe should never exceed 8 t...

Страница 18: ...TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY ROOF FLASHING 18 CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIELD Vertical installation 17...

Страница 19: ...MASONRY CHIMNEY Clay liner Thimble Clean out door 18...

Страница 20: ...FACTORY BUILT THIMBLE 19...

Страница 21: ...BRICK THIMBLE 20...

Страница 22: ...d Hemlock 17 Spruce 17 Pine 17 Bass 16 Low energy yield Fir 13 Data provided by Energy Mines and Resources Canada IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD STOVE The wood must...

Страница 23: ...achieve a medium burn rate Make sure that there s enough air circulation while curing the stove The odours could be smelled during the 3 or 4 first fires Never start your stove outside You will not b...

Страница 24: ...will be achieved according to control setting Low Medium Medium high High SIBERIAN 1200 full close 7 16 7 8 full open SIBERIAN 1600 full close 1 4 5 8 full open SIBERIAN 2000 full close 1 2 1 full ope...

Страница 25: ...ION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creosote The creosote vapours condense in the relatively cool...

Страница 26: ...away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the close container until all cinder...

Страница 27: ...alized product available in the stores where wood stoves are sold The glass should be washed only when cold GASKETING It is recommended that you change the door gasket which makes your stove door air...

Страница 28: ...ires the prior approval of the manufacturer Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the repla...

Отзывы: