Drolet R.C. WOODSTOVE Скачать руководство пользователя страница 15

• 

Inspect the window regularly in order to detect any cracks.  If you spot one, turn 
the stove off immediately, and do not use the stove if the window is broken.  

 

• 

If one of the windows on your stove breaks, you must replace it with one of the 
same type, namely, a   3\16" (5 mm)  thick ceramic glass; never replace the 
window with another material.  

 

• 

To replace the window, remove the screws retaining the window moldings 
inside the door.  Remove the moldings and replace the damaged window with 
the new one.  Perform the procedure backwards after replacing the window.  

 

NOTE: 

Upon replacement of the window, it is possible that the air seal may 
have to be replaced since it is partly glued to the moldings on the 
window. 

 

• 

Never wash the windows with a product that may scratch them: use a 
specialized product, available in the stores where woodstoves are sold. 

 

• 

Windows should be washed only when they are cold.  

 
 
 

Maintenance Of The Chimney 

 
Whether you have a prefab or masonry chimney, you must conduct a visual 
inspection at least once a month in order to be sure that it is in good shape and 
that there is no excessive creosote build-up.  If there is the slightest crack, or 
undulation of the interior or exterior surface of the chimney, repairs or 
replacements of defective parts must be carried out without delay. 
 
You should do at least one chimney sweeping per year, or more if your visual 
inspection reveals creosote deposits exceeding 1\4" (6 mm).  It is important to 
remove all creosote, which has been detached with the sweeping brush, in order 
to prevent if from igniting. 
 

 

 

14

 

Содержание R.C. WOODSTOVE

Страница 1: ...DROLET WOODSTOVE MANUAL R C WOODSTOVE Manufactured by DROLET STOVES FIREPLACES INC 1700 L on Harmel Qu bec Qu bec G1N 4R9 000410 45092A...

Страница 2: ...sembly 4 Installation Of Your Drolet Woodstove 5 Positioning The Stove 5 Floor Protection 5 Clearances 5 Chimney 7 Couplings 8 Air Circulation Systems 9 Operating Your Drolet Woodstove 9 Solid Fuel 9...

Страница 3: ...home or secondary residence This source of energy has the advantage of being abundant relatively cheap and easy to store so that you are assured of energy autonomy for more of less longer periods The...

Страница 4: ...Your Drolet Stove Assembly 3...

Страница 5: ...Refractory Bricks Assembly 4...

Страница 6: ...itated by a blower or the installation of floor or wall grills Important A woodstove must never be installed in a hallway or near a staircase since it may block the way in case of fire or fail to resp...

Страница 7: ...ES AND REAR BACK TOP Minimal requirements 0 013 0 33 mm sheet metal with 1 25 mm fire proof braces 67 50 Ceramic tile or an equivalent fire proof material resting on fire proof brackets spaced 1 25 mm...

Страница 8: ...35 Note that it is the chimney and not the stove which creates the draught effect your stove s performance is directly dependent on an adequate draught from your chimney The following recommendations...

Страница 9: ...ces down Attach each of the sections to one another with three equidistant metal screws The pipes must be short and straight All sections installed horizontally must slope at least 1 4 inch per foot w...

Страница 10: ...uel Your heating unit is designed to burn wood only no other materials should be burned Wastes and other flammable materials should not be burned in your woodstove Any type of wood may be used in your...

Страница 11: ...kened windows Incomplete log combustion Smaller pieces of wood will dry faster All logs exceeding 6 152 mm should be split The wood should be stored in a place where the grass is not too long in such...

Страница 12: ...side the combustion chamber We therefore advise you to leave the door slightly opened a few inches for a 5 to 10 minute period under supervision in order to allow for good combustion After this time y...

Страница 13: ...in such a way that you do not lower the temperature of the combustion gases inside the chimney too much For this purpose we strongly recommend that you install a magnetic thermometer on your smoke ex...

Страница 14: ...ithout delay It is recommend that you change the fiber ceramic seal which makes the seal on your stove door airtight once a year in order to insure good control over the combustion maximum efficiency...

Страница 15: ...e moldings on the window Never wash the windows with a product that may scratch them use a specialized product available in the stores where woodstoves are sold Windows should be washed only when they...

Страница 16: ...val of Drolet Stoves Fireplaces Labour cost and repair work to the account of Drolet Stoves Fireplaces are based on predetermined rate schedule and must not exceed the wholesale price of the replaceme...

Отзывы: