background image

EXCEL-FIRE GAS STOVE 

 

1.  Remove the two door retaining screws at the bottom right and left of the door. 

2.  Remove the door. 

3.  Locate the log grate in the retainers in the right and left rear corners. 

4.  Place the rear log (1) against the rear log stop. Make sure grooves at the back of  the log line 

up with the grates log stop. 

5.  Place logs 2 and 3 against the stops in the middle of the grate. Again see that grooves in the 

the logs line up with the grates log stop. 

6.  Place log 4 into the grooves of logs 1 and 2. 

7.  Log 5 sits over log 4 and 3. 

Rock wool fiber installation 

One small plastic bag is supplied with your unit its filled with rock wool fiber which, when glowing 
red, resembles hot embers.

• 

Place rock wool fiber on top of the front gas ports and up to the grates middle section. 

• 

Put the door back in place. Install the two door retaing screws.

 

Optional 6-inch pipe installation 

Instead of using a standard B-vent pipe it is possible to use a  4" flexible aluminum chimney lining 
system into an existing chimney.  The existing chimney must be a code complying masonry or 
listed fuel burning chimney system: ‘B’ vent, ‘L’ vent UL103 or ULC S629. Refer to the installation 
standards in your area or CAN/CGA B-149 AND ANSI Z223-1 standards (under "venting systems") 
and instruction of flexible pipe manufacturer. 

Warning: always use an approved gas pipe. Never use a conventional 6-inch pipe alone. 

• 

Install the first 4-inch B-vent section or flexible aluminum chimney liner. 

• 

Fasten the optional 6-inch collar adapter to the stove with the two (2) screws supplied. 

• 

Install the sections of the conventional 6-inch pipe. Over the flexible liner. That you want to 
cover up. 

OPERATION INSTRUCTIONS 

Wall thermostat 

The optional wall thermostat will automatically keep your room at an even temperature. You need 
to choose a convenient location for the thermostat. Remember that it should be at least 10 feet 
from the stove and away from direct radiation of the fire. Run the correct gauge wire (see table) 
from the valve to the thermostat and wire as shown in the diagram.(on next page) 

To operate your EXCEL-FIRE using the wall thermostat, follow the lighting procedure and set the 
gas control to the ON position. Simply set your wall thermostat to a comfortable temperature and 
the stove will do the rest. 

During the heating season, you do not have to touch the gas control valve.  If you would like the 
stove off for a while, just set the thermostat to its minimum setting.   However if you do not need 
the stove for quite some time, follow the procedure outlined in the SHUTDOWN  section.  This will 
extinguish the pilot light as well. 

Содержание EXCEL-FIRE

Страница 1: ...nstaller service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENC...

Страница 2: ...lation 7 OPERATION INSTRUCTIONS 7 Wall thermostat 7 Optional blower 8 Blower electrical connection 8 Gas connection 9 Spill switch 9 LIGHTING PROCEDURES 9 Before lighting 9 The first fire 9 Shutdown procedures 10 MAINTENANCE INSTRUCTIONS 10 Glass maintenance 10 Glass door 11 Removal 11 Cleaning 11 Installation 11 Burner removal and installation 11 Removal 11 Installation 12 Gas pressure adjustment...

Страница 3: ...VE THESE INSTRUCTIONS FOR FUTURE REFERENCE This gas stove has been tested by Intertek Testing Services in accordance with canadian CSA 2 22 aM99 CGA 2 17 M91 and U S A ANSI Z21 50 a 1999 UL307B 1995 standards WARNING Installation should be done by a qualified installer Do not burn wood or any other material in this appliance Hot when in operation Keep children furniture clothing and flammable mate...

Страница 4: ... 140 lbs 64 kg Colour metallic black Flue pipe B Vent ou L Vent 4 in 100 mm Clearance to combustibles Back 4 in 102 mm Side 8 in 204 mm Corner 2 in 50 mm Ceiling 48 in 1228 mm Floor Combustible Note 1 Note 1 Your stove has been successfully certified while installed on a wood floor Do not install your stove on carpet Choose instead ceramic tile or wood floor ...

Страница 5: ...f that system at test pressures in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less that psi 3 5 kPa NATURAL GAS The inlet supply or line pressure must be a minimum of 5 INWC and a maximum of 7 INWC The orifice has a 36 ...

Страница 6: ... Provide adequate clearances around air openings into the combustion chamber If the appliance is being installed on combustible flooring such as directly on carpeting tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance A gas appliance must not be connected to a chimney flue serving...

Страница 7: ...EXCEL FIRE GAS STOVE 6 For clearance between pipe and flammable materials follow vent pipe manufacturer s instructions Logs installation ...

Страница 8: ... B 149 AND ANSI Z223 1 standards under venting systems and instruction of flexible pipe manufacturer Warning always use an approved gas pipe Never use a conventional 6 inch pipe alone Install the first 4 inch B vent section or flexible aluminum chimney liner Fasten the optional 6 inch collar adapter to the stove with the two 2 screws supplied Install the sections of the conventional 6 inch pipe Ov...

Страница 9: ... mounting screws Than connect the two wires to the motors connectors If you wish to make a direct electrical connection to the blower without using the six foot cord supplied route a 120 volt 60 Hz electrical power supply line to the same location Remove the power cord and connect the 120V line as per the following procedure Unscrew the speed control unit and pull a few inches away from the juncti...

Страница 10: ...ater Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 2 Make sure that there are no obstructions in the air intake or venting system 3 Clear the immediate area of combustible materials gasoline and other flammable liquids and vapours 4 Make sure that the gas log is in its proper pla...

Страница 11: ... first allow the stove to cool completely Follow the instructions in the section on cleaning under MAINTENANCE INSTRUCTIONS MAINTENANCE INSTRUCTIONS TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE The venting system and the gas stove should be inspected at least once a year Remove the glass front and the logs and clean them if necessary T...

Страница 12: ...e left and right at the bottom of the glass front Remove the glass front assembly CAUTION Do not operate your stove without a glass front or with a broken glass Cleaning Only clean the glass when cold Clean with liquid type cleaners or soap and water do not use abrasive cleaners which can scratch the glass Installation Place the glass front assembly back in position Align the holes for screws Inst...

Страница 13: ...of the gas supply piping system at test pressures equal to or less that psi 3 5 kPa The maximum manifold pressure is set at the factory at 3 5 WC for natural gas and 10 WC for propane To adjust the maximum manifold pressure for altitude the variable gas control knob must then be removed using a special screwdriver Rotate and reinstall the knob so that the maximum pressure reading is correct Locate...

Страница 14: ...unding the burner and the shutter will be exposed underneath Loosen the retaining screw 1 turn before attempting to move the shutter OPTIONS ITEM DESCRIPTION Part no Wall thermostat kit AC05558 130 CFM blower kit with variable speed control AC05914 REPLACEMENT PARTS ITEM DESCRIPTION Part no 6 stove pipe adapter SE9348 Set of logs 5 AC05791 Burner natural gas or propane SE09311 01 Pyroceram Glass 1...

Страница 15: ... qualified technician requires the prior approval of the manufacturer Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its d...