Eco-65 Installation and Operation Manual
31
5.2 Adjustments
5.2.1 Selecting the Combustion Level (Heat Rate)
The heat input of the stove varies between 10,500 BTU/h to 65,000 BTU/h. To change the
combustion level select the + or – button
when the stove is in function.
Note: Input range may vary according to the type of pellets being used.
Even though your stove can burn a large variety of wood pellets, we strongly recommend the
use of high quality pellets to obtain maximum performance out of your stove (see
Section
4.8.1: Proper Fuel
).
Note: To obtain optimal results make sure the venting system, heat exchanger and
exhaust channels are cleaned before performing any setting changes.
5.2.2 Adjusting the Convection Fan Speed
You can adjust the stove’s convection fan speed for each combustion level selected. Thus,
an adjustment range is offered to reduce or increase air distribution in the room. Take note
that not all fan ranges are available, but the speed of the convection blower is consistent with
the requested burn rate. Therefore, if you use your stove in a lower combustion setting, you
will not be able to bring the fan to its maximum capacity. Conversely, for the higher
combustion settings, the lowest convection fan speed is blocked.
If overheating is detected, the convection fan speed will automatically go to the maximum
setting, an error code of F-160 will appear and the convection fan will operate at its highest
setting until the stove reaches a safe temperature. Once the stove reaches that temperature,
it will return to the previously selected convection fan selection.
6 Stove Operation
6.1 First Startup
Before starting your stove, make sure that the burn pot, the baffle and the maintenance
access panels are properly installed. Make sure that the stove has been emptied of all tools
and accessories (see
Section 2.3: Before Operating Your Stove
). Also make sure that the
venting system is properly sealed, that all doors and hopper lid are closed. Make sure that
the hopper is full of pellets. Press the auger button
.
If fire doesn’t start within 20 minutes, a warning code
will appear. Refer to troubleshooting
section for more details.
WARNING: NEVER USE A GRATE OR OTHER MEANS OF SUPPORTING THE FUEL.
ONLY USE THE APPROVED STOVE BURN POT.
Содержание ECO-65
Страница 67: ...Eco 65 Installation and Operation Manual 67 9 Wiring Diagram ...
Страница 76: ...Eco 65 Installation and Operation Manual 76 Remove the bolts H and nuts I to remove the exhaust blower J ...
Страница 79: ...Eco 65 Installation and Operation Manual 79 14 Exploded View and Replacement Parts SECTION A ...
Страница 80: ...Eco 65 Installation and Operation Manual 80 SECTION B ...
Страница 81: ...Eco 65 Installation and Operation Manual 81 SECTION C ...
Страница 82: ...Eco 65 Installation and Operation Manual 82 SECTION D SECTION E ...
Страница 83: ...Eco 65 Installation and Operation Manual 83 SECTION F SECTION G ...
Страница 84: ...Eco 65 Installation and Operation Manual 84 SECTION H SECTION I ...
Страница 85: ...Eco 65 Installation and Operation Manual 85 SECTION J ...