1.3
CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR
To install your appliance correctly, it is extremely important to respect all clearances to any combustibles as
indicated on your stove’s certification label.
Clearances to combustible materials
(See figure 1.3 to match each letter to a clearance)
CLEARANCES (SINGLE WALL PIPE)
CANADA
USA
A
18" (460 mm)
18" (460 mm)
B
18" (460 mm)
18" (460 mm)
C
12" (305 mm)
12" (305 mm)
D
21" (535 mm)
21" (535 mm)
E
28" (715 mm)
28" (715 mm)
F
21" (535 mm)
21" (535 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
CLEARANCES (DOUBLE WALL PIPE)
CANADA
USA
A
18" (460 mm)
18" (460 mm)
B
18" (460 mm)
18" (460 mm)
C
12" (305 mm)
12" (305 mm)
D
21" (535 mm)
21" (535 mm)
E
28" (715 mm)
28" (715 mm)
F
21" (535 mm)
21" (535 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)