DROLET LIMITED LIFETIME WARRANTY 

 

The  warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand 
new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of 
sale), model name and serial number must be supplied when making any warranty claim to your DROLET dealer.   

This  warranty  applies  to  normal  residential  use  only.    Damages  caused  by  misuse,  abuse,  improper  installation,  lack  of 
maintenance, over firing, negligence, accident during transportation, power failures, downdrafts, or venting problems are not 
covered by this warranty. 

This warranty does not cover any scratch, corrosion, warping, or discoloration caused by over firing, abrasives or chemical cleaners. 
Any defect or damage caused by the use of unauthorized parts or others than original parts void this warranty. An authorized qualified 
technician must perform the installation in accordance with the instructions supplied with this product and all local and national 
building codes. Any service call related to an improper installation is not covered by this warranty. 
The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. Returned 
products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will 
repair or replace such defect. Transportation fees to ship the product back to the purchaser will be paid by the manufacturer. Repair 
work covered by the warranty, executed at the purchaser’s domicile by an authorized qualified technician requires the prior approval of 
the manufacturer. Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must 
not exceed the wholesale price of the replacement part. All parts and labour costs covered by this warranty are limited according to the 
table below.   

The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect. The 
manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any 
warranted but defective parts. The manufacturer shall in no event be responsible for any special, indirect, consequential damages of 
any  nature,  which  are  in  excess  of  the  original  purchase  price  of  the  product.  A  one-time  replacement  limit  applies to all parts 
benefiting from a lifetime coverage. This warranty applies to products purchased after March 1

st

 , 2009. 

 

DESCRIPTION 

WARRANTY APPLICATION 

PARTS 

LABOUR 

Combustion chamber (welds only) and castings. 

Lifetime 

3 years 

Stainless steel firebox components, secondary air tubes*, surrounds and heat 
shields, ash drawer, steel legs, pedestal, trims (aluminum extrusions), plating* 
(defective manufacture), and convector air-mate. 

5 years 

3 years 

Carbon steel firebox components, glass retainers, handle assembly, C-Cast 
baffle*, and vermiculite baffle*. 

3 years 

1 year 

Standard blowers, heat sensors, switches, rheostat, wiring, and other controls. 

2 years 

1 year 

Optional blowers, ceramic glass (thermal breakage only*), paint (peeling), 
gaskets, insulation, and ceramic fibre blankets. 

1 year 

n/a 

Firebrick 

n/a 

n/a 

*Pictures required 

 

Shall your unit or a components be defective, contact immediately your 

DROLET 

dealer. Prior to your call make sure you have 

the following information necessary to your warranty claim treatment: 

 

 

Your name, address and telephone number;  

 

Bill of sale and dealer’s name; 

 

Serial number and model name as indicated on the 
nameplate fixed to the back of your unit; 

 

Nature of the defect and any relevant information. 

 

Before shipping your unit or defective component to our plant, you must obtain from your DROLET 
dealer an Authorization Number. Any merchandise shipped to our plant without authorization will be 
refused automatically and returned to sender.

 

Содержание CLASSIC EPA WOOD STOVE

Страница 1: ...ERNATIONAL INC 250 de Copenhague Saint Augustin de Desmaures Quebec Canada G3A 2H3 Tel 418 878 3040 Fax 418 878 3001 www drolet ca This manual is available for free download on the manufacturer s web...

Страница 2: ...y result in property damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installation requirements in your area and the need to obtai...

Страница 3: ...by step installation of your factory built chimney 16 2 2 2 Typical installation through an existing masonry chimney 24 2 3 CHIMNEY CONNECTOR 27 2 4 DRAFT 29 2 5 OUTSIDE COMBUSTION AIR 29 2 6 THE ADV...

Страница 4: ...SECTION 4 0 MAINTENANCE 37 4 1 CLEANING AND PAINTING YOUR STOVE 37 4 2 GLASS 37 4 3 GASKETING 37 4 4 ASH REMOVAL USING THE ASH DRAWER 38 4 5 CHIMNEY FLUE CLEANING 39 DROLET LIMITED LIFETIME WARRANTY 4...

Страница 5: ...nce between the BTU output as indicated on the unit s white EPA label affixed to the glass and the BTU as advertised on our web site and or product literature The maximum BTU output we advertise for t...

Страница 6: ...Use a chimney thermometer installed at a distance of approximately 18 inches on the flue pipe above the stove Flue gases should reach at least 350oF before you close the stove s primary air intake com...

Страница 7: ...YING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE DO NOT CONNECT THIS UNIT...

Страница 8: ...atch each letter to a clearance CLEARANCES SINGLE WALL PIPE CANADA USA A 18 460 mm 18 460 mm B 18 460 mm 18 460 mm C 12 305 mm 12 305 mm D 21 535 mm 21 535 mm E 28 715 mm 28 715 mm F 21 535 mm 21 535...

Страница 9: ...8 FIGURE 1 3 Clearances to combustible materials and floor protection...

Страница 10: ...Only required under the horizontal section of the connector Must exceed each side of the connector by at least 2 inches 51 mm Reduced clearances using shielding You may decrease the clearances by inst...

Страница 11: ...t least 1 25 mm by non combustible spacers see graphic 3 50 33 Ceramic tiles or an equivalent non combustible material on fire proof supports with a minimum of 0 024 0 61 mm sheet metal backing spaced...

Страница 12: ...d combustible ceiling B 20 in 500 mm minimum C 1 in 25 mm minimum D Between 1 in and 3 in 25 mm and 75 mm E 3 in 75 mm minimum F 18 in 457 mm minimum 1 Shielding 2 Non combustible spacers 3 Ceiling pr...

Страница 13: ...3 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 Non combustible support 4 Ceramic tile or non combustible material Graphic 4 A 1 in 25 mm minimum 1 Combustible wall 2 Non combust...

Страница 14: ...Graphic 5 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 Brick Graphique 6 A 1 in 25 mm minimum 1 Combustible wall 2 Non combustible spacers 3 0 024 0 61 mm thick sheet metal 4 Br...

Страница 15: ...ory built chimney with insulation or anyother material Insulation placed in this area could cause adjacent combustibles to overheat Do not use makeshift compromises during installation as they may be...

Страница 16: ...t 2 0 6 m See Figure 2 2 The minimum overall height of the chimney system measured from the stove top to the exterior termination cap of the chimney should be at least 12 3 66m A chimney which is too...

Страница 17: ...ories Wall support system If your chimney must rise along an outside wall you need to connect it to your stove through an adjacent wall For this type of installation the following items are normally r...

Страница 18: ...termine where the chimney will pass through the wall You will probably have to adjust the stove position slightly to ensure that your chimney will run between the studs You can use a stud finder to lo...

Страница 19: ...ons through concrete walls 3 You must first secure the wall thimble into the exterior wall surface Then do the same inside and fasten the trim plate 4 Then from outside the building slide a short chim...

Страница 20: ...using wall bands Wall bands wrap around the chimney and then attach to the wall Install the first one 3 feet above the wall support Then you will need another band for each 8 feet of chimney Note if y...

Страница 21: ...l called CHIMNEY CONNECTOR Ceiling support system If your chimney must rise inside the house and go through the ceiling you need to connect it to your stove at the ceiling level For this type of insta...

Страница 22: ...en the joists You can use a stud finder to locate the joists You also need to take into account the minimum clearances to combustible materials After you have determined where the chimney will go thro...

Страница 23: ...plate is flush with the underside of the ceiling and assembly is level secure it with screws 4 Once the support is secure you can begin to assemble the chimney by lowering the first section into the...

Страница 24: ...ur roof and framed the joists it is time to work outdoors Authorities require that the chimney extend not less than 3 feet above the highest point where it passes through the roof of a building and no...

Страница 25: ...an also install your stove using your existing masonry chimney To do so follow the guidelines below You may want to use a factory built thimble on construct your own brick thimble If you are using a m...

Страница 26: ...25 FIGURE 2 2 2 B Factory Built Thimble...

Страница 27: ...26 FIGURE 2 2 2 C Brick Thimble...

Страница 28: ...nch per foot with the upper end of the section toward the chimney See Figure 2 3 B To insure a good draft the total horizontal length of the connector should never exceed 8 to 10 2 4 to 3 04 m In the...

Страница 29: ...28 FIGURE 2 3 B Minimum Slope Avoid 90 degree eblows We recommend that you use two 45 degree elbows instead...

Страница 30: ...lled to help reduce excessive draft If the addition of elbows is not sufficient a manual damper can be installed in the vertical flue pipe 2 5 OUTSIDE COMBUSTION AIR It is recommended to install 4 out...

Страница 31: ...at the back of your Classic EPA wood stove The blower should be used if you wish to redistribute into a room the heat trapped at the back of your stove By forcing hot air toward the front the blower e...

Страница 32: ...UR STOVE CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE HAZARDOUS 3 1 S...

Страница 33: ...does not exceed 900o F 482o C If you are using a magnetic thermometer make sure that the temperature does not exceed 475o F 246o C If the door handle of the stove becomes excessively hot to the touch...

Страница 34: ...al Dry seasoned cord wood can be distinguished from green wood by the cracks at each end of the logs Wet or green wood will tend to cause the fire to smoulder producing large amounts of creosote Creos...

Страница 35: ...l operating range 3 2 2 Simple wood moisture test Add one large piece of wood to the top of an established fire If it starts to burn on three sides within one minute it is dry and seasoned and right f...

Страница 36: ...ustion in the stove Then bring the red embers to the front of the stove and reload the unit Depending on the type of wood you burn and the strength of the draft in your flue you may have to leave the...

Страница 37: ...mbustion efficiency if the fan is turned on too quick It is possible to have an automatic activation of the blower with the installation of a basic thermodisc kit AC05530 or a quick connect thermodisc...

Страница 38: ...5mm thick ceramic glass Perform the procedure backwards after replacing When replacing the glass you should change the glass gasket to make sure you keep it sealed Never wash the glass with a product...

Страница 39: ...t it will properly seat against the opening edges Tap it down with your poker to ensure proper seating Ashes should be placed in a metal container with a tightly fitting lid This closed container shou...

Страница 40: ...osote makes an extremely hot fire which could be hazardous Your Drolet stove has been designed to reduce the amount of creosote produced Even so the chimney and any chimney connector should be inspect...

Страница 41: ...lacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after ins...