Drive Test GmbH München
Handbuch / Manual BIA Class 2
Seite 20 von 24
Version 3.1
Archive: BIA Klasse 2_25N_DE_EN_V3.1
4
MEASURE
4.1
ENVIRONMENTAL REQUIREMENTS
−
The permissible variation of the temperature of the device is b 10
C + 30
C .
−
The vehicle has to be in a horizontal position.
4.2
HANDLING OF THE INSTRUMENT
Before measuring move the pointer to the origin of the scale.
For measuring put the instrument between the closing edges. Be careful to contact the
initiation area in parallelum to the closing edges. When testing doors with two moving wings,
you are recommended to press the static part of the instrument to one wing and follow the
moving door until the other wing contacts the moveable part of the instrument.
Be careful not to tilt the instrument. Try to prevent any force to the handle; it would distort the
measure.
right
wrong
Figure 7: Positionning of the instrument for measuring
Содержание BIA Class 2
Страница 2: ......
Страница 12: ......
Страница 13: ...BIA Class 2 25 N mm Mechanic Pinch Force Meter for Bus and Railway Doors Manual ...
Страница 14: ......
Страница 24: ......