Unit

Mattress overlay

Environmental parameters

Power supply 

230 V / 50 Hz

 

Protection class 1; IPX0;

 

Type BF, AP/APG NO

Dimensions   200 x 90 x 14 cm without

 

foam pad

Temperatures  

 

Operation 

10 – 35°C

Storage 

-15 – 50°C

Shipment 

-15 – 70°C

Power consumption

 

Max. 12 watts

Cells  

Nylon/PU; 17 cells of which 9

 

are air flow cells, 3 are static 

 

head cells

Relative humidity 

 

Operation

 

20 – 80% => non-condensing

Storage

 

10 – 90% => non-condensing

Weight 

2.2 kg

Cell height   13 cm

Dimensions  

28 x 10 x 20 cm

Cover  

Nylon/PU, breathable, washable

Pressure range 

30 - 60 mbar

Max. load 

36 - 150 kg

Specifications

1

1

2

2

3

3

5

6

4

4

5

6

7

7

8

9

9

10

10

11

12

11

13

8

Type label

1.  Product name
2.  Article number 
3.  Serial number
4.  Production date year/month
5.  Do not dispose of in 

household waste

6.  Follow the instructions for use
7.  CE marking
8.  Do not dry in dryer
9.  Do not iron
10.   Wash in a normal wash cycle 

up to a temperature of 60°C

11.  Do not bleach

1.  Product name
2.  Article number 
3.  Serial number
4.  Production date year/month
5.  Voltage
6.  DIN standard
7.  Follow the instructions for use
8.  CE marking
9.  Type BF
10.  Protection type
11.  Protection class 1 and 2
12.  Do not dispose of in 

household waste

13.  Important

Service life

Our company assumes a long service life for this product as 
long as the product is used as intended and all maintenance 
and service requirements are observed.
This service life can be significantly prolonged if the product 
is carefully handled, maintained, cared for and used.

The service life may also be significantly shortened through 
extreme and improper use, however. 
Determination of the service life by our company does not 
represent any additional guarantee.

Subject to error and change Last 
updated:  01.07.2019  

Manufacturer: Drive Medical GmbH & Co. KG • Leutkircher Straße 44 • D-88316 Isny/Allgäu • Germany • [email protected] • www.drivemedical.de • Tel.: +49 (0) 7562 

9724-0 • Fax: +49 (0) 7562 9724-25 

Distributor: DeVilbiss Healthcare GmbH • Kamenzer Straße 3 • D-68309 Mannheim • Germany • [email protected] • www.drivedevilbiss-int.com • Tel: +49 (0) 621 

17898-0 • Fax: +49 (0) 621 17898-111 

Содержание DeVilbiss Med Aire DuoWave

Страница 1: ...Instructions for use Med Aire DuoWave Alternating Pressure System ...

Страница 2: ... Hand check 5 Alternating pressure function 5 Static function 5 Air flow 5 CPR cardiopulmonary resuscitation 5 Transport function 6 Power failure 6 Alarm function 6 Cleaning disinfection and care 6 Reuse patient change 6 Maintenance service and storage 6 Troubleshooting 7 Disposal 7 Warranty 7 Specifications 8 Type label 8 Service life 8 2 Drive Medical GmbH Co KG Subject to error and change Instr...

Страница 3: ... Decubitus therapy up to and including grade 3 according to EPUAP Static pressure relief positioning is suitable for Patients who only occasionally tolerate dynamic alternating pressure or who do not tolerate it at all Contraindication Body weight less than 36 kg and over 150 kg In the case of unstable fractures particularly of the back cervical and lumbar spine In the case of neurological disease...

Страница 4: ...on adjustable beds for disabled persons a sufficient distance between the top edge of the positioning system and the upper end of the bed rail must be ensured 220 mm according to DIN 1970 2000 If necessary corresponding side rail risers should must be attached to protect the patient Setting up the system TheMedAireDuoWaveisplacedontheexistingmattress Alternatively a 4 or 5 cm high foam pad can als...

Страница 5: ...a 1 1 ratio An alternating cycle involves in each case the inflating and deflating of an air chamber and takes approx 10 minutes The first 3 air chambers in the head area remain static Static function The Med Aire DuoWave has a static function as a standard feature This is switched on using the Static button The LED indicates that the static function is enabled The air chambers all maintain the sa...

Страница 6: ...nd assessments must be performed and documented by suitable technical staff in accordance with DIN EN 62353 Transport function Remove the hose system from the unit and promptly close it with the attached cap Now the mattress is in transport mode To return to normal operation remove the cap on the connection hose and connect it back to the unit and start the unit Note No patient should be positione...

Страница 7: ...anty Damage due to material and or manufacturing errors will be corrected free of charge through a replacement or repair Troubleshooting Symptom Remedy Unit does not work Check whether the plug is correctly inserted Switch on the unit again If the LED on the On Off switch does not light up check the voltage of the outlet or insert the plug into another outlet If the LED on the On Off switch lights...

Страница 8: ...e 2 Article number 3 Serial number 4 Production date year month 5 Voltage 6 DIN standard 7 Follow the instructions for use 8 CE marking 9 Type BF 10 Protection type 11 Protection class 1 and 2 12 Do not dispose of in household waste 13 Important Service life Our company assumes a long service life for this product as long as the product is used as intended and all maintenance and service requireme...

Отзывы: