background image

drive.web automation

Installation & Operation Manual 

Contents

   

 

 

 

 

 

 

 

 

     

   

 

Page 

Design Statements, Warnings

   

 

 

 

 

 

 

1, 2 

smarty

7

 

Models, Options 

   

 

 

 

 

 

 

 

2, 3

 

smarty

7

 Installation, Terminal Naming and Ratings

   

3, 4 

smarty

7

 Wiring, Front Panel

   

 

 

 

 

 

 

smarty

7

 

Serial port, Dimensions, Terminal Map

   

 

smarty

 

Real Time Clock, RTC, FI Notes 

   

 

 

 

Get 

savvy

®

,  USB Plug and Play, Ethernet Networking

 

 

 

Get started with 

savvy

 

engineering & design software 

 

7, 8, 9 

Upgrade 

savvy

 

and

 

smarty

,

 

savvy-SFD

 

Upgrade

   

 

9

 

savvyPanel

®

 

Touch Screen Operator Station

   

 

 

10, 11 

smarty

 Precision Motion Parameters and Connections

 

11 

smarty 

Comms Interfaces, CANopen, Modbus, EIP 

   

12 

Free

 

drive.web

 

Online Training Seminars

   

 

 

 

12

 

Design Statements

This process control equipment to be supplied by Class2, LPS, limited power supply. 
EMC  Standard,  EN  61326-1:  2006,  Electrical  Equipment  for  Measurement,  Control  and 

Laboratory Use. 

 

Emissions Class A, Commercial Equipment. 

 

Immunity Table 2, Industrial Equipment. 

LVD  Standards,  EN  61010-1:  2010,  Safety  Requirements  for  Electrical  Equipment  for 

Measurement, Control and Laboratory Use and;  

 

EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits. 

smarty

 is an industrial controller designed for permanent installation by qualified professionals. 

If  it is used in a manner not specified herein the protection provided may be impaired. 

smarty

 

and its packaging contain recyclable materials 

This  device  is  designed  to  comply  with  Part  15  of   the  FCC  Rules.  Operation  is  subject  to  the  following  two 

conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference 

received, including interference that may cause undesired operation. 

This Class [A] digital apparatus is designed to comply with Canadian ICES-003.   Cet appareil numerique de la 

classe [A] est conforme à la norme NMB-003 du Canada. 

Warning!

 

It is essential that you read and understand this entire manual and the entire contents of  the 

savvy

 

software 

Help

 menu before proceeding with your installation and configuration. See page 6 for 

savvy

 

installation 

instructions. For more information and to download manuals and software, go to

 www.driveweb.com

 or contact 

us. See page 12. 

Warning! 

Your use of  

savvy

 

software and 

drive.web

 

devices may cause motors and machinery to power up 

with  high  Voltages  or  start  or  operate  in  an  unexpected,  dangerous  or  lethal  way.  It  is  essential  that  you  are 

completely  familiar  with  all  of   the  equipment  and  the  system  design  before  attempting  to  program  or  edit  a 

program or connect to any live device. It is also essential that a risk assessment is conducted to identify hazards. 

Risks must be reduced to tolerable levels. 

Warning! 

You are entirely responsible for the configuration or use of  any 

drive.web

 

product. By configuring 

or using these products you agree to indemnify and hold harmless Bardac Corporation, its employees, directors, 

officers, distributors, and resellers against the consequences of  your configuration or use of  the products. 

Warning! 

Information in this manual is subject to change without notice. You are responsible for verifying the 

proper operation of  your 

smarty

. Special care must be taken after loading new firmware or installing new options.

smarty

 

HG504266Iss1.0

 

 

www.driveweb.com

              

              

Page  /12

1

drive.web

SMARTY,  SAVVY,  SAVVYPANEL,  SPEEDY,  BARDAC,  and  DRIVE.WEB  are  trade  marks  of   Bardac 

Corporation, registered in the U.S. and other countries. 

®

Universal Automation Controller

dw250, dw254,  
dw258, & dw259

models

smarty

7

Содержание smarty7 dw250

Страница 1: ...e undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appareil numerique de la classe A est conforme la norme NMB 003 du Canada Warning It is essential...

Страница 2: ...Y THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAG...

Страница 3: ...ource DIN rail mounting Use 35x7 5mm rail per IEC 60715 or EN50022 Environment UL IEC Pollution Degree 2 Operating temperature 0 C min 40 C max Storage temperature 20 C to 50 C Altitude 3000m max Humi...

Страница 4: ...ers Fast transient over Voltage 1kV per EN 61000 4 4 Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individuall...

Страница 5: ...Modbus A 2 0V 3 CAN 4 CAN 5 0V 6 Modbus B 1 2 3 4 5 6 24V 0V FT1 FT2 FT3 FT4 FT5 FT6 TO7 5V 24V 0V DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 24V 0V DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 2B 2B 2A 2A 1B 1B 1A 1A 0V 24...

Страница 6: ...ctory due to shipping restrictions smarty7 Frequency Input Notes FI Terminals FI Digital and Event Input Function Blocks Maximum event frequency is 1 2 FBE cycle s Hz E g for 5ms FBE cycle the max eve...

Страница 7: ...a 2b 1a is converted from hexadecimal to decimal 26 2b similarly is 43 decimal The as shipped address is 10 189 26 43 Use Category 5e cable or better with 8P8C RJ 45 connectors for each drive web devi...

Страница 8: ...of the drive If the icon at right appears a network connection problem exists Check connections LEDs and that the smarty IP address is within the computer s Ethernet subnet mask Warning Importing data...

Страница 9: ...Coupons offline To upgrade savvy go to the Commerce menu select Upgrade savvy check desired options click OK To upgrade smarty choose Upgrade Device in its contextual menu check desired options click...

Страница 10: ...emo with savvy Select File Demo Mode Discover Internet Demo DevicessavvyPanel Pages Systems Page where multiple savvyPanel systems are present A savvyPanel system may contain tiles from many drive web...

Страница 11: ...er manual for detailed instructions Launch savvyPanel via command line or batch file Limit operators to savvyPanel only Specify start system and page Discover devices automatically specifically by dis...

Страница 12: ...meter IDs mapping to PLC5 Supports up to two simultaneous clients ModbusRTU M Master Client S Slave Server X None See pages 2 and 4 Modbus Function Codes FC 01 through 06 and 16 are supported Also spe...

Отзывы: