drive.web automation

smarty

7

 

DRIVE Serial Port

6P6C Socket marked ‘10101’ 
ModbusRTU EIA485. See page 12. 
CANbus connection for 

dw254

dw258

, and 

dw259

. See 

page 12. 1m max. cable length. Do not add termination 

resistors. These are built-in. 

smarty

7

 Dimensions, Overview, and Terminal Map

   

             

 

 

   

        

Spacer Panel Mount Option -

A

smarty

 

HG504266Iss1.0

 

 

www.driveweb.com

              

              

Page  /12

5

1 Modbus-, A

2 0V

3 CAN+

4 CAN-

5 0V

6 , B

1 2 3 4 5 6

24V

0V

FT1

FT2

FT3

FT4

FT5

FT6

TO
7

5V

24V

0V

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

24V

0V

DO1

DO2

DO3

DO4

DO5

DO6

DO7

DO8

2

B-

2

B+

2

A-

2

A+

1

B-

1

B+

1

A-

1

A+

0V

24V

AO
8

AO
7

AO
6

AO
5

AO
4

AO
3

AO
2

AO
1

0V

24V

AI

8

AI

7

AI

6

AI

5

AI

4

AI

3

AI

2

AI

1

0V

24V

17.2mm (0.7”)

90mm

 (3.5”)

119mm (4.7”)

Clock 

Battery 

CR2032

+ side out

Eight Digital Outputs/

Inputs

Eight Analog Outputs

Eight Analog/Digital 

Inputs

Two Incremental 

Encoders

5V, TO7, Six FT

Eight Digital Inputs

Front Panel 

see page 4

108mm (4.25”)

81mm

 (3.19”)

ø4.5mm M4 or #6 Mounting Screws

Содержание smarty7 dw250

Страница 1: ...e undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appareil numerique de la classe A est conforme la norme NMB 003 du Canada Warning It is essential...

Страница 2: ...Y THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAG...

Страница 3: ...ource DIN rail mounting Use 35x7 5mm rail per IEC 60715 or EN50022 Environment UL IEC Pollution Degree 2 Operating temperature 0 C min 40 C max Storage temperature 20 C to 50 C Altitude 3000m max Humi...

Страница 4: ...ers Fast transient over Voltage 1kV per EN 61000 4 4 Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individuall...

Страница 5: ...Modbus A 2 0V 3 CAN 4 CAN 5 0V 6 Modbus B 1 2 3 4 5 6 24V 0V FT1 FT2 FT3 FT4 FT5 FT6 TO7 5V 24V 0V DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 24V 0V DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 2B 2B 2A 2A 1B 1B 1A 1A 0V 24...

Страница 6: ...ctory due to shipping restrictions smarty7 Frequency Input Notes FI Terminals FI Digital and Event Input Function Blocks Maximum event frequency is 1 2 FBE cycle s Hz E g for 5ms FBE cycle the max eve...

Страница 7: ...a 2b 1a is converted from hexadecimal to decimal 26 2b similarly is 43 decimal The as shipped address is 10 189 26 43 Use Category 5e cable or better with 8P8C RJ 45 connectors for each drive web devi...

Страница 8: ...of the drive If the icon at right appears a network connection problem exists Check connections LEDs and that the smarty IP address is within the computer s Ethernet subnet mask Warning Importing data...

Страница 9: ...Coupons offline To upgrade savvy go to the Commerce menu select Upgrade savvy check desired options click OK To upgrade smarty choose Upgrade Device in its contextual menu check desired options click...

Страница 10: ...emo with savvy Select File Demo Mode Discover Internet Demo DevicessavvyPanel Pages Systems Page where multiple savvyPanel systems are present A savvyPanel system may contain tiles from many drive web...

Страница 11: ...er manual for detailed instructions Launch savvyPanel via command line or batch file Limit operators to savvyPanel only Specify start system and page Discover devices automatically specifically by dis...

Страница 12: ...meter IDs mapping to PLC5 Supports up to two simultaneous clients ModbusRTU M Master Client S Slave Server X None See pages 2 and 4 Modbus Function Codes FC 01 through 06 and 16 are supported Also spe...

Отзывы: