background image

drive.web automation

smarty

 

HG503894Iss2.0

 

 

www.driveweb.com

              

              

Page  /16

8

0V

DI1

DI3

DI5

DI7

DO1

DO3

DO5

DO7

0V

A01

AO3

AO5

AO7

AI1

AI3

AI5

AI7

0V

0V

1A+

1B+

1Z+

0V

0V

2A+

2B+

2Z+

0V

CI1

0V

FI1

FI3

FI5

0V

0V

T

PW

TO
2

TO
4

TO
6

24V

DI2

DI4

DI6

DI8

DO2

DO4

DO6

DO8

0V

A02

AO4

AO6

AO8

AI2

AI4

AI6

AI8

0V

5V

1A-

1B-

1Z-

0V

5V

2A-

2B-

2Z-

0V

CI2

5V

FI2

FI4

FI6

5V

24V

TO
1

TO
3

TO
5

TO
7

0V

0V

0V

0V

0V

0V

0V

24V

0V

24V

0V

A

B

0V

1A+

1A-

1B+

1B-

0V

2A+

2A-

2B+

2B-

Carrier C4 

Terminals 

and Dimensions

XIO Port 4P4C

W

id

th

 O

ve
ra

ll, 

2

1

0

mm 

(8

.2

7

”)

H

e

ig

h

t O

ve
ra

ll,

 

8

9

mm 

(3

.5

”)

Real-time Clock 
Battery, CR2032.
(Not included)

+ -

DRIVE 8P8C 
CANopen Serial Port

Содержание smarty dw24 Series

Страница 1: ...ding interference that may cause undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appareil numerique de la classe A est conforme la norme NMB 003 du...

Страница 2: ...G IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Product Identification smarty The smarty dw24X Series Universal Automation Controllers UAC consist of a C...

Страница 3: ...TO Frequency stepper digital sinking output 350mA shared 30VDC max 500kHz max 10k pull up to TPWR 5VDC for FT terminals and C5 C5 TO are 5VDC max Caution TO are sinking outputs without internal over c...

Страница 4: ...urce DIN rail mounting Use 35x7 5mm rail per IEC 60715 or EN50022 Environment UL IEC Pollution Degree 2 Operating temperature 0 C min 50 C max Storage temperature 20 C to 60 C Altitude 3000m max Humid...

Страница 5: ...input ModbusRTU serial port is brought out to terminals instead of the jack in C2 smarty C4 Carrier 4 adds to C3 Two 4 20mA current inputs Also 0 20mA 20 4mA and 20 0mA 100 input impedance Six freque...

Страница 6: ...7 DO1 DO3 DO5 DO7 0V A01 AO3 AO5 AO7 AI1 AI3 AI5 AI7 0V 24V DI2 DI4 DI6 DI8 DO2 DO4 DO6 DO8 0V A02 AO4 AO6 AO8 AI2 AI4 AI6 AI8 0V 24V Clock Battery CR2032 Not included C2 Only XIO Port 4P4C C2 Only DR...

Страница 7: ...AI5 AI7 0V 0V 1A 1B 0V 0V FT1 FT3 24V DI2 DI4 DI6 DI8 DO2 DO4 DO6 DO8 0V A02 AO4 AO6 AO8 AI2 AI4 AI6 AI8 0V 5V 1A 1B 0V 5V FT2 FT4 0V 0V 0V 0V 0V 24V 0V A B Carrier C3 Terminals and Dimensions XIO Por...

Страница 8: ...TO2 TO4 TO6 24V DI2 DI4 DI6 DI8 DO2 DO4 DO6 DO8 0V A02 AO4 AO6 AO8 AI2 AI4 AI6 AI8 0V 5V 1A 1B 1Z 0V 5V 2A 2B 2Z 0V CI2 5V FI2 FI4 FI6 5V 24V TO1 TO3 TO5 TO7 0V 0V 0V 0V 0V 0V 0V 24V 0V 24V 0V A B 0V...

Страница 9: ...y CR2032 Not included XIO Port 4P4C 63mm 2 48 57mm 2 24 J7 J8 J9 DRIVE XIO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...

Страница 10: ...FI3 FI4 FI5 FI6 485 A 485 B 0V 24V 0V 5V 1A 1A 1B 1B 1Z 1Z 0V CI1 0V Lefthand Flex Side DRIVE 8P8C CANopen Serial Port 104mm 4 09 27mm 1 06 0V DO8 DO7 DO6 DO5 0V DO4 DO3 DO2 DO1 0V 24V 0V DI8 DI7 DI6...

Страница 11: ...utputs for use with motion control function blocks FI Frequency Inputs Useful for lower frequencies 10kHz Duty cycle is also measured Updates every FBE cycle or two edge cycle smarty XIO Digital IO Mo...

Страница 12: ...for each drive web device and the host computer For systems with more than one drive web device use an Ethernet switch for all drive web devices and computer Get started with savvy We strongly recomm...

Страница 13: ...Icon Contextual Menu Change Name Name your smarty for easy identification Import Export Device Data Load save configuration data to from this smarty only Unlock Lock Set Password Choose Restrict Modif...

Страница 14: ...execution order from top down Change execution order by dragging function blocks up or down the list In this picture ENC1 Speed function block is moved so that it is processed after ENC Phase Lock sav...

Страница 15: ...in Java based savvyPanel Appears as graphic tile in iOS Function blocks enable savvyPanel actions Alarm Annunciator Provides a system wide alarm annunciation when active Touch to view page 255 Presenc...

Страница 16: ...read only or have incoming drive web connections Click the Comms Server icon in the FBE or SFD view dwOption 04 ModbusTCP IP slave server Supported Modbus Function Codes 1 thru 6 15 and 16 Supports u...

Отзывы: