background image

1.  Remove contents from packaging and lay Table Top

(1) upside down on flat surface with Mounting Bracket 

(5) facing upward.  See Fig. 2.

2.  Stand the Column Assembly (2) right side up as shown 

in Fig. 1.  Ensure Trip Rod (15) is visible in the rectan-

gular tube (as shown), but not protruding out of the 

top.  If necessary, shake the Column Assembly (2) 

until the Trip Rod (15) drops into place inside the Col-

umn Assembly (2). Next, insert the Trip Lever (3), with 

rounded side facing up, into the Column Assembly (2) 

as shown, ensuring that the flat side of the Trip Lever 
(3) rests on the Trip Rod. (15)

3.  While holding the Trip Lever (3) securely in place on 

top of the Trip Rod (15), flip the Column Assembly (2) 

upside down and insert the Column Assembly (2) into 
the table top Mounting Bracket (5) as shown in Fig. 2.  

4.  Align horizontal hole in table top Mounting Bracket 

(5) with horizontal hole in Column Assembly (2) and 

hole through Trip Lever (3).  Insert 1/4 x 20 Bolt (4) into 

horizontal hole & secure with Nut (4).  Tighten with 
10mm wrench.  See Fig. 3. 

5.  Install two Domed Phillips Head bolts and locking 

washers (6) through the vertical holes in the Mounting 

Bracket (5) and into the threaded holes in Column As-
sembly (2) as shown in Fig. 4.

Assembly Instructions

Drive Medical

OVERBED TABLES - 13003/13067

6.  Install two Casters With Lock (8) into Base (7) which 

connects to Column Assembly (2). Install two 

Non-Locking Casters (9) into base opposite Column 

Assembly (2).  See Fig. 5.

7.  Install two Bolt Sleeves (10) into upside down Base (7) 

and then position two Bolts (12) through Bolt Plate 

(11) and into Bolt Sleeves (10).  Position Base (7) over 

Column Assembly (2) and thread bolts into bottom of 

Column Assembly (2) and tighten using 16mm wrench.  

See Fig. 6.

8.  Turn the table upright and stand on casters.
9. 

CAUTION:

 This step must be completed last to 

prevent damage to the spring loaded mechanism.  

Remove the Black Screw (13) in the Column Assembly 

(2) collar labeled “Remove for Assembly” and replace 

it with the Chrome Screw (14) contained in hardware 

package.  Do not remove Chrome Screw labeled “Do 

Not Remove”.  See Fig. 7 and Fig. 8.

FIG. 3

4

3

2

FIG. 2

1

2

5

FIG. 1

(15)

TRIP LEVER

(3)

2

6

6

FIG. 4

2

5

FIG. 7

Remove 13

FIG. 8

Insert 14

CAUTION

FOR SAFETY – DO NOT REMOVE BLACK SCREW (13) ON COL-
UMN ASSEMBLY (2) UNTIL THE TABLE IS FULLY ASSEMBLED AND 
STANDING IN UPRIGHT POSITION.  AFTER REMOVING BLACK 
SCREW, REPLACE WITH CHROME SCREW (14) INCLUDED IN 
HARDWARE PACKAGE. 

 

CAUTION

THE BOTTOM CHROME SCREW WITH THE “DO NOT REMOVE” 
LABEL IS NEVER REMOVED AS IT WILL DAMAGE THE MECHANISM. 