To set your desired cold flow rate,

 

Step 1: Press the Red Coffee Icon & Blue Cup Icon Together for 5 seconds

Step 2: Dispense From the Blue Cup Icon into a Cup or Pitcher, You're desired amount of 

Water

Step 3: Once You reach your desired amount, Press The Blue Icon to Stop.

Step 4: Wait 5 Seconds and the Onyx Will Save the Setting by returning to Normal Use

You will see the blue cup blinking. 

You can only start by increasing the Temperature. 

Press the Blue Icon to increase the 

Press the blinking icon to Increase the Temperature

To Decrease the Cold Temperature, Press the Small Coffee Cup Icon. 

Hot

92

In order to switch to the Hot temperature mode, simply press the top left lock button once. 

Now, you will see the red coffee mug icon blink. 

To Increase the temperature, press the Red Coffee Mug Icon. To decrease the temperature, 

press the cup icon on the right. 

In order to Switch to the Reboil Feature, press the top left Lock Button once. 

Now you will find the Reboil icon Blinking. 

Press the Coffee Cup Icon to Increase the Temperature. Press the Cold Cup Icon to 

decrease the temperature. 

To exit the setting, press the Bottom Right Icon. 

SCAN HERE

TO WATCH VIDEO

Содержание DPWPA700CTB

Страница 1: ...Onyx ...

Страница 2: ...perty please read and follow below instructions carefully 1 Always operate the product from a power source of the same voltage frequency and rating as indicated on the product identification marking 2 Do not operate this product if it has malfunctioned damaged cord or plug or appears damaged in any way Return the complete product to the place of purchase for inspection repair or replacement 3 This...

Страница 3: ...y 4 Top cover 5 Condenser _______ __ 6 Heating System Switch ON 1 OFF 0 7 Water inlet 2 OPERATION USER INTERFACE UI DAINKPOD 0 0 0 8 Side Panel 9 Back panel 10 Front panel 11 Power cords 12 Stage 1 filter Particle Chemical Scrub 13 Stage 2 filter U RA Polishing Scrub D f1 II Ill 02 ...

Страница 4: ...default volume is 1 Liter hot water LJ light show red when dispensing over LJ Light turn back white you can press any button to stop in advance B When the machine is in heating status LJ light always show red Until the heating over LJ turn back show white 3 Reboiling Extra hot button Red and white two color light and used to start and close the reboil function when reboiling function is activated ...

Страница 5: ...ue to the temperature difference between cold and hot water The designed mixed water temperature is 30 45 c b Mixed water principal cold water and hot water are dispensing separately cold water is dispensed first and hot water is dispensed after the cold water is over B When UVC led working shows blue When UVC stops shows white when UVC fail the flash blue all the time UVC Led Working principle Af...

Страница 6: ...ress the blinking icon to Increase the Temperature To Decrease the Cold Temperature Press the Small Coffee Cup Icon Hot 92 In order to switch to the Hot temperature mode simply press the top left lock button once Now you will see the red coffee mug icon blink To Increase the temperature press the Red Coffee Mug Icon To decrease the temperature press the cup icon on the right In order to Switch to ...

Страница 7: ...DPFLT07TK DPFLT08TK ...

Страница 8: ...hown on the below make sure the heating switch on the back of the machine Is on OFF 0 status Note ON 1 side OFF 0 side 2 Hot water first filling operation After power on the Obutton lights up and show red and flashing First of all you must press Oand then push LPbutton to dispense hot water for 1 liters till water come out from nozzle 3 Cold water first filling operation After the hot water first ...

Страница 9: ...the cooling start temperature after 4 minutes the compressor protection function ends MACHINE WORKING PRINCIPLE Touch display board Night light Hot water inlet solenoid valve Cold water inlet solenoid valve Relay 1 Relay 2 Hot wire Adapter c J c J Neutrelwira Heating switch CIRCUIT DIAGRAM Cold water inlet val U AC t Hot water NTC sensor Cold water NTC sensor Flow meter UVC LED Cold NTC sensor Col...

Страница 10: ...For detailed instructions see installation manual ...

Страница 11: ...chine No suspending in midair in case of falling off 6 Take out the pin of the quickjoint at the rear of the product s base plate and then take out the blue plug Insert the waterinlet PE pipe in the quickjoint and tighten the pin 7 The water cooler plug cord into a ground fault interrupter receptacle After installing supply power and begin to use the Water purifier 8 When installing filter and rep...

Страница 12: ...machine grounded properly Noisy operation Not installed steadily Place the machine on a steady solid surface Machine fails to run Power supply not put through Switch on power supply Q and Flash Drying heating Power off and turn on machine again The night light flash red Filter life expires Change new filter and Re setting The key flash blue UVC fails Change new UVC LED Notes It is a normal state t...