Stream height is factory set at 35 PSI. If supply pressure varies
greatly from this, remove Items 1 & 2 and adjust screw on
Item 4. Clockwise adjustment will raise stream and counter-
clockwise adjustment will lower stream. For best adjustment,
stream should hit basin approximately 6-1/2" (165mm) from
bubbler.