Connecting the supply cable to the mains
Install a standardized plug corresponding to the load indicated on the data plate.
When connecting the cable directly to the mains, install an omnipolar circuit-breaker
with a minimum contact opening of 3 mm between the appliance and the mains. The
omipolar circuit breaker should be sized according to the load and should comply
with current regulations (the earth wire should not be interrupted by circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of
more than 50 with respect to the room temperature, anywhere along its length.
Before making the connection, check that:
the electrical safety of this appliance can only be guaranteed if the cooker is
correctly and efficiently earthed, ways ensure that the earthing is efficient; if
you have any doubts call in a qualified technician to check the system. The
manufacturer declines all responsibility for damage resulting from a system
which has not been earthed.
Before plugging the appliance into the mains, check that the specifications
indicated on the date plate (on the appliance and/or packaging) correspond to
those of the electrical mains system of your home.
Check that the electrical capacity of the system and sockets will support the
maximum power of the appliance, as indicated on the data plate. If you have
any doubts, call in a qualified technician.
If the socket and appliance plug are not compatible, have the socket replaced
with a suitable model by a qualified technician. The latter, in particular, will
also have to ensure that the cross section of the socket cables are suitable
for the power absorbed by the appliance. The use of adapters, multiple
sockets and/or extensions, is not recommended. If their use cannot be
avoided, remember to use only single or multiple adapters and extensions
which comply with current safety regulations. In these cases, never exceed
the maximum current capacity indicated on the single adapter or extension
and the maximum power indicated on the multiple adapter. The plug and
socket must be easily accessible.