3. ANNUAL CLEANING:

 

• Activation of the carbon filter.

 

Only installed extractors are applied as a re-circulation unit (not ventilated outside). This 
filter catches the odors and must be changed at least once a year depending on the use 
given. Buy these filters from your dealer (with the reference number that appears on the 
nameplate inside the extractor) and take control when you change them. 

 

DANGER: 

Disconnect the extractor before servicing: 

  Remove the filter. 

• Place the new carbon filter into the blower of the extractor inside the surface, and 
then put it directly. 

• Repeat the same operation for each of the filters. 

• Arrange the filter again. 

4.  CHANGING THE BULBS 

Disconnect or shut off the extractor before beginning maintenance. 

MODEL USING BULB LIGHTS OR NEON TUBE

  

  Unscrew the screw securing the light cover. 

  Tilt back. 

  The type of bulb you use is 2W LED, replace the light 

bulb and screw the new one (see diagram) 

 

 

Содержание PRISMA ISLA TOUCH 90

Страница 1: ......

Страница 2: ...User Manual RANGE HOOD PRISMA TOUCH 90 2 1 FOR YOUR SECURITY 3 2 EXTRACTOR DESIGN 3 3 CLEANING AND MAINTENANCE 5 4 CHANGING THE BULBS 6 5 INSTALATION 7 ...

Страница 3: ... not allowed to be used on a solid fuel stove wood coal etc These extractors have been designed for private use in the home for constant product improvements We reserve the right to make changes in its technical functional or aesthetic characteristics as results of technical developments These kitchen extractors were designed exclusively for the cooking of beverages and food products These product...

Страница 4: ... the speed does not change 3 Time key Press the key button for three seconds to set the clock for the time the time icon will flash then touch the minus key reduce one hour press and hold the key to continuously reduce Touch the plus key it will increase by one hour press and hold to increase continuously Touch the time timing button when setting the clock position switch to the minute setting pos...

Страница 5: ...uct that is diluted in water then rinse in clean water and dry with gentle cleansing 2 MONTHLY CLEANING FILTER CARTRIDGE Clean the filter every month to prevent fire hazard The filter collects grease and dirt as it is an element that plays an important role in the efficiency of the extractor It can be flammable if saturated with grease residues Clean with commercially available home product rinse ...

Страница 6: ...ide the extractor and take control when you change them DANGER Disconnect the extractor before servicing Remove the filter Place the new carbon filter into the blower of the extractor inside the surface and then put it directly Repeat the same operation for each of the filters Arrange the filter again 4 CHANGING THE BULBS Disconnect or shut off the extractor before beginning maintenance MODEL USIN...

Страница 7: ...t to the outside All our appliances have the option to operate in re circulation with no outlet to the outside Under these circumstances add a charcoal filter activator which will catch odors See instructions on page 7 This filter is available through your dealer under the reference number indicated on the nameplate See inside the extractor MOUNTING Pre assembly recommendations The extractor must ...

Страница 8: ...valve and place it outdoors Place two chimneys in the extractor Drill 2 holes of 8 mm in a suitable place according to the second plate place two screws in the direction of the plate then remove the internal chimney at a suitable height Put the inner chimney on the second plate and tighten the two screws ELECTRIC CONNECTION This appliance is supplied with a H05V VF power cable with 3 cores of 0 75...

Страница 9: ...t 3 mm This double bipolar isolator will also be required if the outlet is not accessible We will not be responsible for accidents resulting from incorrect or non existent ground events Your fuse should be 10 or 16 amps Power Input 140W 180W 220W Voltage Range 110 127V 220 240V 110 127V 220 240V 110 127V Range Frequency 50HZ 60 HZ 50HZ 60 HZ 50HZ Current Rating 0 8 1 5A 0 8 1 5A 0 8 1 5A ...

Страница 10: ...User Manual RANGE HOOD PRISMA TOUCH 90 10 ...

Отзывы: