Dri-Eaz VORTEX F174 Скачать руководство пользователя страница 1

 

07-00211F F174, F174-BLU 

Legend Brands, Inc.

 

 

 

 

Axial Airmover 

Owner’s Manual 

Model F174, F174-BLU 

LEGEND BRANDS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233, USA 

Phone: 800-932-3030

 

Fax: 360-757-7950

 

www.dri

-

eaz.com

  

This Dri-Eaz airmover will ventilate confined spaces or propel dry air across large open areas to aid in drying.  

Improve indoor air quality; remove unwanted odors. May be used with up to 125 ft. of semi-rigid ducting. 

Patents

http://www.LBpatents.com

 

R E A D   A N D   S A V E   T H E S E   I N S T R U C T I O N S

WARNING!

 To reduce the risk of fire or 

electric shock, do not use this fan with any 
solid-state speed control device. 

WARNING!

 Unit must be grounded. Do 

not use with an extension cord. Use only on GFCI protected re-
ceptacles. 

WARNING!

 Do not touch grills when unit is operating. 

NOTICE:

 Keep motor dry. For indoor use only.  

NOTICE:

 Unplug when not in use or when moving unit.  

NOTICE:

 Do not allow children to play with or around the unit. 

Be sure the unit is inaccessible to children when not attended.  

NOTICE:

 Always operate the unit on a stable, level surface so 

it cannot fall and cause injury. 

WARNING!

 Do not alter or modify the product in any way. Use 

only replacement parts authorized by Legend Brands, Inc. 
Modifications or use of unapproved parts could create a hazard 
and will void your warranty. Contact your authorized Dri-Eaz 
distributor for assistance. 

WARNING! 

a) Do not operate any fan with a damaged cord or plug. Dis-
card fan or return to an authorized service facility for examina-
tion and/or repair. 

b) Do not run cord under carpeting. Do not cover cord with 
throw rugs, runners, or similar coverings. Do not route cord un-
der furniture or appliances. Arrange cord away from traffic area 
and where it will not be tripped over. 

BEFORE YOU BEGIN 

Warranty registration 

Please visit 

warranty.legendbrandsrestoration.com 

 to register 

your purchase. Registration allows us to better assist you with 
using, maintaining or servicing your equipment and to contact 
you in case we have important safety information concerning 
your Dri-Eaz product. If you determine service is required, 
have your equipment model, serial number and original proof 
of purchase available and call your distributor for assistance 
with obtaining a return material authorization (RMA). 

 

OPERATING INSTRUCTIONS 

The Vortex Axial Fan is designed for air ventilation, circulation, 
and extraction, and for drying of wet materials and structures 
with airflow. 

When operating the Vortex, note the airflow arrow on the hous-
ing, indicating which way the air moves. The Vortex can be 
used with or without attached ducting. It is useful for either pos-
itive or negative airflow, that is, blowing air into or extracting air 
from spaces. 

Inspect the inlet and outlet screens before plugging in the unit, 
and remove any debris that may restrict airflow. 

When Used with Ducting 

Do not install ducting when the Vortex is operating. To install 
ducting, first note the direction of airflow. Place end of ducting 
over the duct ring and attach securely. Ducting to fit the Vortex 
is available from your Dri-Eaz distributor. Ducting has quick 

Содержание VORTEX F174

Страница 1: ...r return to an authorized service facility for examina tion and or repair b Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord un der furn...

Страница 2: ...mage Units with damaged cords must be removed from service and re paired before use Failure to do so may lead to electrical shock or a fire hazard Exterior Inspection Evaluate exterior components and...

Страница 3: ...duct length Replace motor Unit runs but vibrates excessively Dirt has built up on fan blade Severe jolt has bent motor shaft so unit is out of balance Fan blade is damaged Clean fan blade Replace mot...

Страница 4: ...trolando AVISO Siempre operar la unidad sobre una superficie estable y nivelada para que no pueda caerse ni causar le siones ADVERTENCIA No alterar ni modificar de ninguna manera su equipo Utilice s l...

Страница 5: ...untado hacia esa pared del ex tremo para as evitar bolsones de aire inm vil y para mantener aire fresco circulando por todos los lugares MANTENIMIENTO PRECAUCI N Los procedimientos de repara ci n inte...

Страница 6: ...a pero vibra excesiva mente Se ha acumulado suciedad en las aspas del ventilador Un fuerte golpe ha doblado el eje del mo tor por lo que la unidad est desbal anceada Las aspas del ventilador est n da...

Страница 7: ...lisez toujours l appareil sur une surface stable et de niveau de mani re viter une chute qui pourrait entra ner des blessures AVERTISSEMENT N alt rez pas ou ne modifiez pas votre Vortex en aucune fa o...

Страница 8: ...un mur d extr mit pour viter des poches d air immobile et maintenir la circu lation d air frais dans tous les endroits MAINTENANCE ATTENTION Les proc dures de r paration in terne doivent tre effectu...

Страница 9: ...ssive De la salet s est accumul e sur la lame du ventilateur Une secousse brusque a courb l arbre du moteur et l appareil est d s quilibr La lame du moteur est endommag e Nettoyez la lame du ventilate...

Отзывы: