07-02292A F571-115V 

Dri-Eaz Products, Inc. 

maintain a healthy level of humidity. Using the Cube may 
also prevent secondary damage caused by high humid-
ity. 

How the Cube works 

The Cube refrigerant dehumidifier uses a fan to draw 
moist air in and condenses it into water that collects in a 
tray and is automatically pumped out through a drain 
hose. The unit can be set to operate continuously or the 
user may select Humidistat Mode. In Humidistat Mode, 
the Cube will turn on and off automatically to maintain 
the inlet humidity level the user has selected.  

CONTROLS AND OPERATING INSTRUC-
TIONS 

Set unit upright 

NOTICE: Always store, transport, and use the unit in 
a horizontal position. If the unit is ever placed in a 
vertical position, return it to the horizontal position 
and let it stand for at least 30 minutes before turning 
it on.  

Positioning a Dehumidifier 

For best results, operate your dehumidifiers in an en-
closed area. Close all doors and windows that open to 
the outside to maximize water removal efficiency. Place 
your dehumidifier away from obstructions, and keep it 
away from anything that could block airflow into and out 
of the unit. For more information about creating an opti-
mum drying environment, contact Dri-Eaz at 
800-932-3030. 

Set up drain hose 

The Cube condensate pump connects to a plastic drain-
age hose. This hose is equipped with a quick-connect fit-
ting for quick attachment to the provided 20 ft. (6 m) 
drain hose. Unwrap the entire hose and place the unat-
tached end in a sink, drain, bucket or outdoors 

– any-

where that water can drain out safely. If you use a 
bucket or other container for water collection, check it 
regularly to prevent overflows. 

NOTICE: 

Uncoil and straighten the entire drain hose. Do 

not leave any part of the hose coiled and do not place 
the end of the hose higher than 20 ft. (6 m) above the 
bottom of the unit. Also check for kinks or other obstruc-
tions that might restrict the flow of water. Obstructions 
may cause a water backup and result in overflows.

 

Plug in electrical cord 

The Cube should be plugged into a GFCI-protected 115 
volt outlet rated for at least 15

 

amps.  

Startup display and normal display modes 

When unit is first plugged in to AC power, the control 
panel display will briefly cycle through a series of 

readouts. This is part of the unit

’s self-diagnosis proce-

dure and no user intervention is required.  

Turn the unit on 

The control panel on the Cube dehumidifier has a dis-
play and a touchpad with four keys. Press the 

 

ON/OFF

 

to turn the unit on. The unit will now go 

through a compressor delay countdown (up to sixty sec-
onds in duration) and a self-diagnostics process.  

Once the compressor delay countdown and self-diag-
nostics are complete, the display will switch to normal 
display mode.  

 

UNIT ON  00 HRS 

 

INLET 00°C / INLET 00% 

 

The 

first line

 of the display shows the total number of 

hours the unit has been in operation. This value may be 
reset to zero to track job hours (see “Job Hours Reset” 
below). The 

second line

 of the display alternates be-

tween inlet temperature and inlet humidity. 

User Settings Menu 

A number of display settings may be changed by the 
user. System information can also be displayed. These 
items are accessed by pressing 

 

DISPLAY MENU. 

Each press of the key will display the next parameter. 
When you reach the parameter you wish to adjust, press 

 

MENU SELECTION to increase the value. Press 

 

DISPLAY MENU again to accept the setting and re-start 
the display cycle.  

 

ON/OFF 

Press and release to turn unit 
on  
or off. 

DISPLAY MENU 

Press to select next item in 
menu. Menu item will show 
in display.  

MENU SELECTION / 
UP KEY 

Press to toggle or select val-
ues in menu displayed.  

PURGE PUMP 

Press and release to start 
purge. Display will count 
down seconds remaining until 
purge is complete.  

CONTROL PANEL  

ON/OFF  

DISPLAY  

DISPLAY 
MENU 

MENU SELECTION / 
UP KEY 

PURGE PUMP 

Содержание F571-115V

Страница 1: ...plug not the cord to unplug Insert three prong plug on power cord into a match ing electrically grounded outlet Do not use adapter Never cut off third prong Do not use an extension cord The unit must...

Страница 2: ...20 ft 6 m above the bottom of the unit Also check for kinks or other obstruc tions that might restrict the flow of water Obstructions may cause a water backup and result in overflows Plug in electrica...

Страница 3: ...he unit completes the compressor delay the display shows UNIT ON XX HRS and cycles between INLET XX F and INLET XX NOTE If no compressor delay countdown is displayed a delay is not necessary and the m...

Страница 4: ...T OUTLET 100 80 115 30 For information only 3 GRAIN DPR XX GPP XX X g kg for 230V models 4 FILTER CLEANED XXX HRS 5 FILTER CLEANED 0 HRS Press to clear filter hours 5 COIL CLEANED XXX HRS 5 COIL CLEAN...

Страница 5: ...ensure any water re maining on interior surfaces falls into the sump area 3 Press the PURGE key When the purge cycle is complete turn the unit off 4 Remove the external drain hose drain it carefully c...

Страница 6: ...ck valve and pump basin may need to be cleaned Remove grills and cover as shown in Fig B Remove screws from pump base and lift out pump Wipe out pump basin with a damp cloth Inspect the pump base for...

Страница 7: ...ture and in let RH every 2 seconds None HUMIDISTAT INLET XXX F XX First line indicates unit is in humidistat mode Second line Toggles between inlet temperature and in let RH every 2 seconds None LOW T...

Страница 8: ...or ER4 OUTLET SENSOR CONNECT Temp sensor is open missing or shorted Check that temp sensors are installed cor rectly on control panel If error persists contact service ER5 SENSOR CONNECTION ON BD Inl...

Страница 9: ...essary Check coils Clean as necessary If the problem you are experiencing is not listed here call your local distributor or contact our Service Department toll free at 800 932 3030 for further assista...